Use of monoatomic and polyatomic projectiles for the characterisation of polylactic acid by static secondary ion mass spectrometry

被引:8
|
作者
Boschmans, B [1 ]
Van Royen, P [1 ]
Van Vaeck, L [1 ]
机构
[1] Univ Antwerp CDE, Dept Chem, MiTAC, B-2610 Antwerp, Belgium
关键词
D O I
10.1002/rcm.2089
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The application of polyatomic primary ions is a strongly developing branch of static secondary ion mass spectrometry (S-SIMS), since these projectiles allow a significant increase in the secondary ion yields to be achieved. However, the different limitations and possibilities of certain polyatomic primary ions for use on specific functional classes of samples are still not completely known. This paper compares the use of monoatomic and polyatomic primary ions in S-SIMS for thin layers of polylactic acid (PLA), obtained by spin-coating solutions on silicon wafers. Bombardment with Ga+, Xe+ and SF5+ primary ions allowed the contribution of the projectile mass and number of atoms in the gain in ion yield and molecular specificity (relative importance of high m/z and low m/z signals) to be assessed. Samples obtained by spin-coating solutions with increasing concentration showed that optimal layer thickness depended on the primary ion used. In comparison with the use of Ga+ projectiles, the yield of structural ions increased by a factor of about 1.5 to 2 and by about 7 to 12 when Xe+ and SF5+ primary ion bombardment were applied, respectively. A detailed fragmentation pattern was elaborated to interpret ion signal intensity changes for different projectiles in terms of energy deposition and collective processes in the subsurface, and the internal energy of radical and even-electron precursor ions. Copyright (C) 2005 John Wiley & Sons, Ltd.
引用
收藏
页码:2517 / 2527
页数:11
相关论文
共 50 条
  • [21] The use of secondary ion mass spectrometry in radiotoxicology
    Amaral, A
    Cossonnet, C
    Galle, P
    RADIATION PROTECTION DOSIMETRY, 1998, 79 (1-4) : 137 - 140
  • [22] Speciation of sodium nitrate and sodium nitrite using kiloelectronvolt energy atomic and polyatomic and megaelectronvolt energy atomic projectiles with secondary ion mass spectrometry
    Van Stipdonk, MJ
    Justes, DR
    Force, CM
    Schweikert, EA
    ANALYTICAL CHEMISTRY, 2000, 72 (11) : 2468 - 2474
  • [23] STATIC SECONDARY ION MASS-SPECTROMETRY OF POLYMERIC BIOMATERIALS
    DAVIES, MC
    LYNN, RAP
    CRITICAL REVIEWS IN BIOCOMPATIBILITY, 1990, 5 (04): : 297 - 341
  • [24] Characterisation of fulvic acids and glycyrrhizic acid by time-of-flight secondary ion mass spectrometry
    Szymczak, W
    Wolf, M
    Wittmaack, K
    ACTA HYDROCHIMICA ET HYDROBIOLOGICA, 2001, 28 (07): : 350 - 358
  • [25] STATIC SECONDARY ION MASS-SPECTROMETRY OF POLYMER SYSTEMS
    GARDELLA, JA
    HERCULES, DM
    ANALYTICAL CHEMISTRY, 1980, 52 (02) : 226 - 232
  • [26] Speciation analysis of oxides with static secondary ion mass spectrometry
    Cuynen, E
    Van Vaeck, L
    Van Espen, P
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1999, 13 (23) : 2287 - 2301
  • [27] New Cs sputter ion source with polyatomic ion beams for secondary ion mass spectrometry applications
    Belykh, S. F.
    Palitsin, V. V.
    Veryovkin, I. V.
    Kovarsky, A. P.
    Chang, R. J. H.
    Adriaens, A.
    Dowsett, M. G.
    Adams, F.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2007, 78 (08):
  • [28] The influence of polyatomic primary ion chemistry on matrix effects in secondary ion mass spectrometry analysis
    Alnajeebi, Afnan M.
    Vickerman, John C.
    Lockyer, Nicholas P.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2018, 32 (22) : 1962 - 1970
  • [29] Microscopical speciation analysis with laser microprobe mass spectrometry and static secondary ion mass spectrometry
    Van Vaeck, L
    Adriaens, A
    Adams, F
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1998, 53 (02) : 367 - 378
  • [30] Secondary ion mass spectrometry in the characterisation of boron-based ceramics
    Daolio, S
    Fabrizio, M
    Piccirillo, C
    Muolo, ML
    Passerone, A
    Bellosi, A
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (01) : 1 - 7