High current arc erosion on copper electrodes in air

被引:0
|
作者
Oyvang, Thomas
Fjeld, Elin
Rondeel, Wilhelm
Hagen, Svein Thore
机构
关键词
moving arc; copper; melting; vaporization;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An arc fault inside metal enclosed switchgear will cause the pressure to rise and vaporization of electrode material may contribute to the pressure rise. An experimental study of high current arc erosion on copper electrodes in air has been performed, with an evaluation of fraction lost by gross melting and vaporization. All experiments were performed at NEFI High Voltage Laboratory in Skien, Norway. The measured mass loss from vaporization in our experiments seems to be negligible compared to erosion by gross melting.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] NON-EQUILIBRIUM PLASMA PROPERTIES OF ELECTRIC ARC DISCHARGE IN AIR BETWEEN COPPER ELECTRODES
    Boretskij, V.
    Veklich, A.
    Cressault, Y.
    Gleizes, A.
    Teulet, Ph
    PROBLEMS OF ATOMIC SCIENCE AND TECHNOLOGY, 2012, (06): : 181 - 183
  • [32] Erosion Characteristics of Copper-Based Composite Electrodes in an Electric Arc of Variable Length with Transverse Gas Blowing
    Budin, A. V.
    Pinchuk, M. E.
    Kurakina, N. K.
    TECHNICAL PHYSICS LETTERS, 2018, 44 (09) : 808 - 810
  • [33] Erosion Characteristics of Copper-Based Composite Electrodes in an Electric Arc of Variable Length with Transverse Gas Blowing
    A. V. Budin
    M. E. Pinchuk
    N. K. Kurakina
    Technical Physics Letters, 2018, 44 : 808 - 810
  • [34] The influence of the arc current on the cold electrode erosion
    Essiptchouk, AM
    Marotta, A
    Sharakhovsky, LI
    PHYSICS OF PLASMAS, 2003, 10 (09) : 3770 - 3773
  • [35] Investigation of CuCr Electrodes Microstructure After Effect of a High Current Vacuum Arc
    Schneider, Anton V.
    Yakolev, Evgeniy V.
    Popov, Sergey A.
    Batrakov, Alexander V.
    PROCEEDINGS OF THE 2018 28TH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM (ISDEIV 2018), VOL 1, 2018, : 235 - 238
  • [36] HIGH-CURRENT DENSITY SUBMERGED ARC-WELDING WITH TWIN ELECTRODES
    HINKEL, JE
    FORSTHOEFEL, FW
    WELDING JOURNAL, 1976, 55 (03) : 175 - 180
  • [37] THE HIGH-CURRENT METAL VAPOR ARC COLUMN BETWEEN SEPARATING ELECTRODES
    HEBERLEIN, JVR
    GORMAN, JG
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 1980, 8 (04) : 283 - 288
  • [38] ELECTRODES FOR AIR-ARC TREATMENT OF CASTINGS
    LEVCHENKOV, VI
    BESFAMILNYI, VP
    WELDING PRODUCTION, 1984, 31 (01): : 22 - 24
  • [39] Analysis of erosion susceptibility for tungsten electrodes in submerged arc welding
    Astafeva, Natala
    Astafev, Anatoliy
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE: AVIAMECHANICAL ENGINEERING AND TRANSPORT (AVENT 2018), 2018, 158 : 30 - 34
  • [40] Air Arc Simulation In Low Voltage Electrodes
    Kim, Keewon
    Lee, Jeong Su
    Joo, Hyun Woo
    Bae, Chae Yoon
    Ahn, Kil Young
    Kim, Young Geon
    2022 6TH INTERNATIONAL CONFERENCE ON ELECTRIC POWER EQUIPMENT - SWITCHING TECHNOLOGY (ICEPE-ST), 2022, : 233 - 236