Multipixel system for gigahertz frequency-domain optical imaging of finger joints

被引:29
作者
Netz, Uwe J. [1 ]
Beuthan, Juergen [1 ]
Hielscher, Andreas H. [2 ,3 ]
机构
[1] Charite Univ Med Berlin, Inst Med Phys & Lasermed, D-14195 Berlin, Germany
[2] Columbia Univ, Dept Biomed Engn, New York, NY 10027 USA
[3] Columbia Univ, Dept Radiol, New York, NY 10027 USA
关键词
D O I
10.1063/1.2840344
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Frequency-domain optical imaging systems have shown great promise for characterizing blood oxygenation, hemodynamics, and other physiological parameters in human and animal tissues. However, most of the frequency domain systems presented so far operate with source modulation frequencies below 150 MHz. At these low frequencies, their ability to provide accurate data for small tissue geometries such as encountered in imaging of finger joints or rodents is limited. Here, we present a new system that can provide data up to 1 GHz using an intensity modulated charged coupled device camera. After data processing, the images show the two-dimensional distribution of amplitude and phase of the light modulation on the finger surface. The system performance was investigated and test measurements on optical tissue phantoms were taken to investigate whether higher frequencies yield better signal-to-noise ratios (SNRs). It could be shown that local changes in optical tissue properties, as they appear in the initial stages of rheumatoid arthritis in a finger joint, are detectable by simple image evaluation, with the range of modulation frequency around 500 MHz proving to yield the highest SNR. (C) 2008 American Institute of Physics.
引用
收藏
页数:14
相关论文
共 52 条
[1]  
BERNDT KW, 1991, P SOC PHOTO-OPT INS, V1431, P149, DOI 10.1117/12.44186
[2]   Detection and characterization of optical inhomogeneities with diffuse photon density waves: A signal-to-noise analysis [J].
Boas, DA ;
OLeary, MA ;
Chance, B ;
Yodh, AG .
APPLIED OPTICS, 1997, 36 (01) :75-92
[3]   Spatio-temporal imaging of the hemoglobin in the compressed breast with diffuse optical tomography [J].
Boverman, Gregory ;
Fang, Qianqian ;
Carp, Stefan A. ;
Miller, Eric L. ;
Brooks, Dana H. ;
Selb, Juliette ;
Moore, Richard H. ;
Kopans, Daniel B. ;
Boas, David A. .
PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (12) :3619-3641
[4]   Magnetic resonance-guided near-infrared tomography of the breast [J].
Brooksby, B ;
Jiang, SD ;
Dehghani, H ;
Pogue, BW ;
Paulsen, KD ;
Kogel, C ;
Doyley, M ;
Weaver, JB ;
Poplack, SP .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (12) :5262-5270
[5]   COMPARISON OF TIME-RESOLVED AND TIME-UNRESOLVED MEASUREMENTS OF DEOXYHEMOGLOBIN IN BRAIN [J].
CHANCE, B ;
LEIGH, JS ;
MIYAKE, H ;
SMITH, DS ;
NIOKA, S ;
GREENFELD, R ;
FINANDER, M ;
KAUFMANN, K ;
LEVY, W ;
YOUNG, M ;
COHEN, P ;
YOSHIOKA, H ;
BORETSKY, R .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1988, 85 (14) :4971-4975
[6]  
Chance B, 1999, P SPIE, V3597
[7]  
Chance B, 1997, P SPIE, V2979
[8]  
CHANCE B, 1995, P SPIE, V2389
[9]   Diffuse optical tomography of breast cancer during neoadjuvant chemotherapy: A case study with comparison to MRI [J].
Choe, R ;
Corlu, A ;
Lee, K ;
Durduran, T ;
Konecky, SD ;
Grosicka-Koptyra, M ;
Arridge, SR ;
Czerniecki, BJ ;
Fraker, DL ;
DeMichele, A ;
Chance, B ;
Rosen, MA ;
Yodh, AG .
MEDICAL PHYSICS, 2005, 32 (04) :1128-1139
[10]   Three-dimensional diffuse optical tomography in the parallel plane transmission geometry: Evaluation of a hybrid frequency domain/continuous wave clinical system for breast imaging [J].
Culver, JP ;
Choe, R ;
Holboke, MJ ;
Zubkov, L ;
Durduran, T ;
Slemp, A ;
Ntziachristos, V ;
Chance, B ;
Yodh, AG .
MEDICAL PHYSICS, 2003, 30 (02) :235-247