Wind loads on roof-mounted isolated solar panels of tall buildings through wind tunnel testing

被引:31
作者
Dai, S. F. [1 ]
Liu, H. J. [1 ]
Yang, J. H. [2 ]
Peng, H. Y. [1 ]
机构
[1] Harbin Inst Technol, Sch Civil & Environm Engn, Shenzhen, Peoples R China
[2] Guangxi Univ, Coll Civil Engn & Architecture, Nanning, Peoples R China
基金
中国国家自然科学基金;
关键词
Wind load; Isolated solar panel; Rooftop; Tall building; Building height; Wind tunnel test; FLAT-ROOF; ARRAYS; SIMULATION; PARAMETERS; PRESSURE;
D O I
10.1016/j.solener.2021.12.005
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A series of pressure tests were conducted to systematically investigate the wind loads on isolated solar panels mounted on the rooftops of tall buildings. The effects of panel location, tilt angle (beta = 15 degrees, 30 degrees, and 451, and building height (H = 24, 48, 72, and 96 m) were examined. Peak loads from taps were found two times as large as that from modules and panels. An increase in H induced a decrease in the largest mean and negative peak net panel force coefficients, which is attributed to the enhanced two-dimensionality of flows for buildings with lower heights. Specifically, the largest most critical negative peak net panel force coefficients at H = 24 m were approximately 20% larger than those at H = 96 m. Attention should be paid to wind loads on roof-mounted solar panels attached to buildings with lower heights. Besides, buildings with lower heights tend to cause more significant fluctuations of wind pressure on solar panels. Moreover, rooftop solar panels on buildings with lower heights are likely to have positive mean panel force coefficients due to the flow reattachment over roofs.
引用
收藏
页码:607 / 622
页数:16
相关论文
共 40 条
[1]   Effect of roof shape, wind direction, building height and urban configuration on the energy yield and positioning of roof mounted wind turbines [J].
Abohela, Islam ;
Hamza, Neveen ;
Dudek, Steven .
RENEWABLE ENERGY, 2013, 50 :1106-1118
[2]  
[Anonymous], 2012, Design Specification for Photovoltaic Power Plants
[3]  
[Anonymous], 2017, Photovoltaic Power Generation Systems
[4]  
[Anonymous], 2012, WIND LOADS LOW PROF
[5]  
[Anonymous], 2012, 500092012 GB
[6]  
[Anonymous], 2019, Unified Design Standards for Civil Buildings
[7]  
ASCE, 2010, Minimum Design Loads for Buildings and Other Structures, P7
[8]  
Barlow JB., 1999, Low-Speed Wind Tunnel Testing
[9]   Towards better performances for a novel rooftop solar PV system [J].
Behura, Arun Kumar ;
Kumar, Ashwini ;
Rajak, Dipen Kumar ;
Pruncu, Catalin, I ;
Lamberti, Luciano .
SOLAR ENERGY, 2021, 216 :518-529
[10]   Wind loading on tilted roof-top solar arrays: The parapet effect [J].
Browne, Matthew T. L. ;
Gibbons, Michael P. M. ;
Gamble, Scott ;
Galsworthy, Jon .
JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2013, 123 :202-213