Direct determination of pesticides in vegetable samples using gold nanoelectrode ensembles

被引:16
作者
Lu, Xuxiao [1 ]
Bai, Huiping [1 ]
Ruan, Qiong [1 ]
Yang, Minghui [2 ]
Yang, Guangming [1 ]
Tan, Lin [1 ]
Yang, Yunhui [1 ]
机构
[1] Yunnan Normal Univ, Coll Chem & Chem Engn, Kunming, Peoples R China
[2] Hunan Univ, Coll Chem & Chem Engn, State Key Lab Chemo Biosensing & Chemometr, Changsha 410082, Hunan, Peoples R China
关键词
pesticides; sensor; gold nanowire; polycarbonate membrane; nanoelectrode ensembles;
D O I
10.1080/03067310801902500
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Gold nanowires were produced by electrodeposition in polycarbonate membrane, with an average diameter of 200 nm and a height of about 2 m. The nanowire array prepared by the proposed method can be considered as nanoelectrode ensembles (NEEs). An amperometric pesticides sensor based on gold NEEs has been developed and used for determination of phoxim and dimethoate in vegetable samples. The electrochemical performance of the gold NEEs has also been studied by the amperometric method. The electrode provided a linear response over a concentration range of 5.9 10-5 to 1.2 10-2 M for phoxim with a detection limit of 4.8 10-6 M and 6.3 10-5 to 1.1 10-2 M for dimethoate. This sensor displayed high sensitivity and selectivity, long-term stability and wide linear range. In addition, the ellipsis of enzyme and the reactivation of enzyme make the operation simple. This sensor has been used to determine pesticides in a real vegetable sample.
引用
收藏
页码:813 / 824
页数:12
相关论文
共 27 条
[1]   Splitless large-volume GC-MS injection for the analysis of organophosphorus and organochlorine pesticides in vegetables using a miniaturised ethyl acetate extraction [J].
Agüera, A ;
Piedra, L ;
Hernando, MD ;
Fernández-Alba, AR ;
Contreras, M .
ANALYST, 2000, 125 (08) :1397-1402
[2]   Multiresidue determination of pesticides in plants by high-performance liquid chromatography following gel permeation chromatographic clean-up [J].
Balinova, A .
JOURNAL OF CHROMATOGRAPHY A, 1998, 823 (1-2) :11-16
[3]   Determination of organophosphate pesticides at a carbon nanotube/organophosphorus hydrolase electrochemical biosensor [J].
Deo, RP ;
Wang, J ;
Block, I ;
Mulchandani, A ;
Joshi, KA ;
Trojanowicz, M ;
Scholz, F ;
Chen, W ;
Lin, YH .
ANALYTICA CHIMICA ACTA, 2005, 530 (02) :185-189
[4]  
Eto M., 1974, ORGANOPHOSPHORUS PES
[5]   Potentiometric biosensors for cholinesterase inhibitor analysis based on mediatorless bioelectrocatalysis [J].
Ghindilis, AL ;
Morzunova, TG ;
Barmin, AV ;
Kurochkin, IN .
BIOSENSORS & BIOELECTRONICS, 1996, 11 (09) :873-880
[6]   Determination of phoxim residues in eggs by using high-performance liquid chromatography diode array detection after treatment of stocked housing facilities for the poultry red mite (Dermanyssus gallinae) [J].
Hamscher, G. ;
Priess, B. ;
Nau, H. .
ANALYTICA CHIMICA ACTA, 2007, 586 (1-2) :330-335
[7]   Electrochemical biosensing platforms using platinum nanoparticles and carbon nanotubes [J].
Hrapovic, S ;
Liu, YL ;
Male, KB ;
Luong, JHT .
ANALYTICAL CHEMISTRY, 2004, 76 (04) :1083-1088
[8]   Chlropyrifos-methyl shows anti-androgenic activity without estrogenic activity in rats [J].
Kang, HG ;
Jeong, SH ;
Cho, JH ;
Kim, DG ;
Park, JM ;
Cho, MH .
TOXICOLOGY, 2004, 199 (2-3) :219-230
[9]  
KANG QH, 2003, J CHROMATOGR, V21, P421
[10]   Conversion of pre-RISC to holo-RISC by Ago2 during assembly of RNAi complexes [J].
Kim, Kevin ;
Lee, Young Sik ;
Carthew, Richard W. .
RNA, 2007, 13 (01) :22-29