摘要
Presented are experimental results from 24 full-scale push test specimens to study the behaviour of composite beams with trapezoidal profiled sheeting laid transverse to the beam axis. The tests use a single-sided horizontal push test setup and are divided into two series. First series contained shear loading only and the second had normal load besides shear load. Four parameters are studied: the effect of wire mesh position and number of its layers, placing a reinforcing bar at the bottom flange of the deck, normal load and its position, and shear stud layout. The results indicate that positioning mesh on top of the deck flange or 30 mm from top of the concrete slab does not affect the stud's strength and ductility. Thus, existing industry practice of locating the mesh at a nominal cover from top of the concrete slab and Eurocode 4 requirement of placing mesh 30 mm below the stud's head are both acceptable. Double mesh layer resulted in 17% increase in stud strength for push tests with single stud per rib. Placing a T16 bar at the bottom of the deck rib did not affect shear stud behaviour. The normal load resulted in 40% and 23% increase in stud strength for single and double studs per rib. Use of studs only in the middle three ribs out of five increased the strength by 23% compared to the layout with studs in first four ribs. Eurocode 4 and Johnson and Yuan equations predicted well the stud strength for single stud/rib tests without normal load, with estimations within 10% of the characteristic experimental load. These equations highly under-estimated the stud capacity, by about 40-50%, for tests with normal load. AISC 360-16 generally over-estimated the stud capacity, except for single stud/rib push tests with normal load. Nellinger equations precisely predicted the stud resistance for push tests with normal load, with ratio of experimental over predicted load as 0.99 and coefficient of variation of about 8%. But, Nellinger method over-estimated the stud capacity by about 20% in push tests with single studs without normal load.
引用
收藏
页码:475 / 494
页数:20
相关论文
共 50 条
  • [1] Behaviour of Headed Shear Stud in Composite Beams with Profiled Metal Decking
    Qureshi, Jawed
    Lam, Dennis
    ADVANCES IN STRUCTURAL ENGINEERING, 2012, 15 (09) : 1547 - 1558
  • [2] An experimental investigation of the fire behaviour of demountable composite beams with profiled steel decking
    Long, Jiejie
    Wang, Yongchang
    Lou, Guobiao
    Hu, Zhiyou
    Yang, Tao
    Tan, Qinghua
    Ke, Lu
    ENGINEERING STRUCTURES, 2024, 307
  • [3] Prospective study on the behaviour of composite beams with an indented shear connector
    Rita, Alves Ana
    Isabel, B. Valente
    Washintgon, B. Vieira
    Gustavo, S. Verissimo
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2018, 148 : 508 - 524
  • [4] Effect of shear connector spacing and layout on the shear connector capacity in composite beams
    Qureshi, Jawed
    Lam, Dennis
    Ye, Jianqiao
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2011, 67 (04) : 706 - 719
  • [5] Composite beams with nonlinear material and connector behaviour for low degrees of partial shear connection
    Bartschi, Roland
    Fontana, Mario
    COMPOSITE CONSTRUCTION IN STEEL AND CONCRETE V, 2006, : 573 - +
  • [6] Perforated shear connector for composite steel and concrete beams
    Machacek, J
    Studnicka, J
    Krpata, A
    Svitakova, M
    COMPOSITE AND HYBRID STRUCTURES, VOLS 1 AND 2, 2000, : 297 - 304
  • [7] CHARACTERISATION OF DEMOUNTABLE SHEAR CONNECTOR SYSTEMS IN COMPOSITE BEAMS
    Kozma, Andras
    Odenbreit, Christoph
    Braun, Matthias, V
    PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON STEEL AND ALUMINIUM STRUCTURES (ICSAS19), 2019, : 742 - 753
  • [8] An experimental and analytical study of a new shear connector for composite steel-concrete beams
    Matus, RA
    Jullien, JF
    ADVANCES IN STEEL STRUCTURES, VOLS 1 AND 2, 1996, : 413 - 418
  • [9] Experimental study on flexural behaviour of partially encased cold-formed steel composite beams using rebar as shear connector
    Salih, Musab N. A.
    Tahir, Mahmood Md
    Mohammad, S.
    Ahmad, Y.
    Sulaiman, A.
    Shek, P. N.
    Abraham, Achmad
    Firdaus, Muhammad
    Aminuddin, K. M.
    Khadavi
    10TH ASIA PACIFIC STRUCTURAL ENGINEERING AND CONSTRUCTION CONFERENCE 2018, 2019, 513
  • [10] Experimental studies on the behaviour of headed shear studs for composite beams in fire
    Lim, Ohk Kun
    Choi, Sengkwan
    Kang, Sungwook
    Kwon, Minjae
    Choi, J. Yoon
    STEEL AND COMPOSITE STRUCTURES, 2019, 32 (06): : 743 - 752