Impact of prompt gamma coincidence correction on absorbed dose estimation in differentiated thyroid cancer using 124I PET/CT imaging

被引:3
作者
Wierts, Roel [1 ]
Conti, Maurizio [2 ]
Claessen, Anouk G. G. [1 ]
Herrmann, Ken [3 ]
Kemerink, Gerrit J. [1 ]
Binse, Ina [3 ]
Wildberger, Joachim E. [1 ]
Mottaghy, Felix M. [1 ,4 ]
Backes, Walter H. [1 ]
Jentzen, Walter [3 ]
机构
[1] Maastricht Univ, Dept Radiol & Nucl Med, Med Ctr, P Debyelaan 25, NL-6229 HX Maastricht, Netherlands
[2] Siemens Healthcare Mol Imaging, Knoxville, TN USA
[3] Univ Hosp Essen, Dept Nucl Med, Essen, Germany
[4] Rhein Westfal TH Aachen, Dept Nucl Med, Univ Hosp, Aachen, Germany
关键词
I-124; lesion dosimetry; prompt gamma coincidence correction; thyroid carcinoma; PURE POSITRON EMITTERS; RADIOIODINE THERAPY; DOSIMETRY;
D O I
10.1097/MNM.0000000000000911
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction Iodine-124 positron emission tomography/computed tomography (I-124 PET/CT) is increasingly being used in the absorbed dose estimation in the radioiodine treatment of differentiated thyroid cancer (DTC). However, the produced prompt gamma coincidences (PGCs) associated with the I-124 decay result in a bias in the absorbed dose estimation. The impact of a sinogram-based PGC correction approach on the absorbed dose estimation in I-124 PET/CT DTC imaging is investigated. Methods I-124 phantom and patient measurements were performed on a Siemens Biograph mCT PET/CT system. All images were reconstructed with (PGC(on)) and without PGC correction (PGC(off)). The phantom contained seven spheres (diameters: 6.6-37 mm). The spheres and background compartment were filled with a I-124 solution, resulting in a low (9.4 : 1) and a high sphere-to-background activity concentration ratio (750 : 1). Sphere recovery coefficient (RC) values were determined. In addition, the impact of PGC correction on measured lesion uptake and calculated lesion-absorbed dose was assessed for 66 lesions identified in 24 DTC patients. Results PGC correction systematically increased sphere RC values up to 71% for the smallest spheres. For the patient data, PGC correction significantly increased both the measured I-124 uptake (P<0.005) and the calculated lesion-absorbed dose (P=0.008) by similar to 3%. The percentage difference in the calculated lesion-absorbed dose ranged from -19% to 50%, showing that PGC correction had a variable and large impact for a few lesions. Conclusion PGC correction resulted in significantly higher sphere RC values, I-124 lesion uptake values and estimated lesion-absorbed doses.
引用
收藏
页码:1156 / 1164
页数:9
相关论文
共 24 条
[1]   A Recommendation for Revised Dose Calibrator Measurement Procedures for 89Zr and 124I [J].
Beattie, Bradley J. ;
Pentlow, Keith S. ;
O'Donoghue, Joseph ;
Humm, John L. .
PLOS ONE, 2014, 9 (09)
[2]   PET imaging with the non-pure positron emitters: 55Co, 86Y and 124I [J].
Braad, P. E. N. ;
Hansen, S. B. ;
Thisgaard, H. ;
Hoilund-Carlsen, P. F. .
PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (09) :3479-3497
[3]   Physics of pure and non-pure positron emitters for PET: a review and a discussion [J].
Conti, Maurizio ;
Eriksson, Lars .
EJNMMI PHYSICS, 2016, 3 (01)
[4]   Revised American Thyroid Association Management Guidelines for Patients with Thyroid Nodules and Differentiated Thyroid Cancer [J].
Cooper, David S. ;
Doherty, Gerard M. ;
Haugen, Bryan R. ;
Kloos, Richard T. ;
Lee, Stephanie L. ;
Mandel, Susan J. ;
Mazzaferri, Ernest L. ;
McIver, Bryan ;
Pacini, Furio ;
Schlumberger, Martin ;
Sherman, Steven I. ;
Steward, David L. ;
Tuttle, R. Michael .
THYROID, 2009, 19 (11) :1167-1214
[5]   Optimization and assessment of quantitative 124I imaging on a Philips Gemini dual GS PET/CT system [J].
Gregory, Rebecca A. ;
Hooker, Claire A. ;
Partridge, Mike ;
Flux, Glenn D. .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 (07) :1037-1048
[6]  
Hayden CHJ, 2011, US Patent, Patent No. [7
[7]  
894 : 652, 72011894652]
[8]  
Jentzen W, 2011, Q J NUCL MED MOL IM, V55, P21
[9]   Optimized 124I PET dosimetry protocol for radioiodine therapy of differentiated thyroid cancer [J].
Jentzen, Walter ;
Freudenberg, Lutz ;
Eising, Emst G. ;
Sormenschein, Wilfried ;
Knust, Jochen ;
Bockisch, Andreas .
JOURNAL OF NUCLEAR MEDICINE, 2008, 49 (06) :1017-1023
[10]   Iodine-124 PET dosimetry in differentiated thyroid cancer:: recovery coefficient in 2D and 3D modes for PET(/CT) systems [J].
Jentzen, Walter ;
Weise, Reiner ;
Kupferschlaeger, Juergen ;
Freudenberg, Lutz ;
Brandau, Wolfgang ;
Bares, Ronald ;
Burchert, Wolfgang ;
Bockisch, Andreas .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 (03) :611-623