Automated Surveillance to Detect Postprocedure Safety Signals of Approved Cardiovascular Devices

被引:52
作者
Resnic, Frederic S. [1 ]
Gross, Thomas P. [3 ]
Marinac-Dabic, Danica [3 ]
Loyo-Berrios, Nilsa [3 ]
Donnelly, Sharon [1 ]
Normand, Sharon-Lise T. [2 ,4 ]
Matheny, Michael E. [5 ,6 ]
机构
[1] Brigham & Womens Hosp, Boston, MA 02115 USA
[2] Harvard Univ, Sch Med, Dept Hlth Care Policy, Boston, MA 02115 USA
[3] US FDA, Ctr Devices & Radiol Hlth, Silver Spring, MD USA
[4] Harvard Univ, Sch Publ Hlth, Dept Biostat, Boston, MA 02115 USA
[5] Tennessee Valley Healthcare Syst, Vet Adm Med Ctr, Nashville, TN USA
[6] Vanderbilt Univ, Med Ctr, Nashville, TN USA
来源
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION | 2010年 / 304卷 / 18期
关键词
INTERVENTIONAL CARDIOLOGY; RANDOMIZED-TRIAL; MEDICAL DEVICE; STENTS; CATHETERIZATION; COMPLICATIONS; METAANALYSIS; REGISTRY; HOLES; RISK;
D O I
10.1001/jama.2010.1633
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Context Ensuring the safety of medical devices challenges current surveillance approaches, which rely heavily on voluntary reporting of adverse events. Automated surveillance of clinical registries may provide early warnings in the postmarket evaluation of medical device safety. Objective To determine whether automated safety surveillance of clinical registries using a computerized tool can provide early warnings regarding the safety of new cardiovascular devices. Design, Setting, and Patients Prospective propensity-matched cohort analysis of 7 newly introduced cardiovascular devices, using clinical data captured in the Massachusetts implementation of the National Cardiovascular Data Repository CathPCI Registry for all adult patients undergoing percutaneous coronary intervention from April 2003 through September 2007 in Massachusetts. Main Outcome Measure Presence of any safety alert, triggered if the cumulative observed risk for a given device exceeded the upper 95% confidence interval (CI) of comparator control device. Predefined sensitivity analyses assessed robustness of alerts when triggered. Results We evaluated 74 427 consecutive interventional coronary procedures. Three of 21 safety analyses triggered sustained alerts in 2 implantable devices. Patients receiving Taxus Express2 drug-eluting stents experienced a 1.28-fold increased risk of post-procedural myocardial infarction (2.87% vs 2.25%; absolute risk increase, 0.62% [95% CI, 0.25%-0.99%]) and a 1.21-fold increased risk of major adverse cardiac events (4.24% vs 3.50%; absolute increase, 0.74% [95% CI, 0.29%-1.19%]) compared with those receiving alternative drug-eluting stents. Patients receiving Angio-Seal STS vascular closure devices experienced a 1.51-fold increased risk of major vascular complications (1.09% vs 0.72%; absolute increased risk, 0.37% [95% CI, 0.03%-0.71%]) compared with those receiving alternative vascular closure devices. Sensitivity analyses confirmed increased risk following use of the Taxus Express2 stent but not the Angio-Seal STS device. Conclusion Automated prospective surveillance of clinical registries is feasible and can identify low-frequency safety signals for new cardiovascular devices. JAMA. 2010;304(18):2019-2027 www.jama.com
引用
收藏
页码:2019 / 2027
页数:9
相关论文
共 34 条
[1]   Clinical characteristics and in-hospital outcome of patients with end-stage renal disease on dialysis referred for implantable cardioverter-defibrillator implantation [J].
Aggarwal, Atul ;
Wang, Yongfei ;
Rumsfeld, John S. ;
Curtis, Jeptha P. ;
Heidenreich, Paul A. .
HEART RHYTHM, 2009, 6 (11) :1565-1571
[2]   The Relative Ability of Different Propensity Score Methods to Balance Measured Covariates Between Treated and Untreated Subjects in Observational Studies [J].
Austin, Peter C. .
MEDICAL DECISION MAKING, 2009, 29 (06) :661-677
[3]   Some Methods of Propensity-Score Matching had Superior Performance to Others: Results of an Empirical Investigation and Monte Carlo simulations [J].
Austin, Peter C. .
BIOMETRICAL JOURNAL, 2009, 51 (01) :171-184
[4]  
Brindis R G, 2001, J Am Coll Cardiol, V37, P2240, DOI 10.1016/S0735-1097(01)01372-9
[5]   Modernizing Device Regulation. [J].
Garber, Alan M. .
NEW ENGLAND JOURNAL OF MEDICINE, 2010, 362 (13) :1161-1163
[6]  
Gross T P, 1996, Stud Health Technol Inform, V28, P17
[7]  
Hammill S, 2006, HEART RHYTHM, V3, P470, DOI 10.1016/j.hrthm.2006.01.019
[8]   INTERMACS: Interval Analysis of Registry Data [J].
Holman, William L. ;
Pae, Walter E. ;
Teutenberg, Jeffrey J. ;
Acker, Michael A. ;
Naftel, David C. ;
Sun, Benjamin C. ;
Milano, Carmelo A. ;
Kirklin, James K. .
JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2009, 208 (05) :755-761
[9]   Arterial puncture closing devices compared with standard manual compression after cardiac catheterization -: Systematic review and meta-analysis [J].
Koreny, M ;
Riedmüller, E ;
Nikfardjam, M ;
Siostrzonek, P ;
Müllner, M .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2004, 291 (03) :350-357
[10]   Bivalirudin and provisional glycoprotein IIb/IIIa blockade compared with heparin and planned glycoprotein IIb/IIIa blockade during percutaneous coronary intervention - REPLACE-2 Randomized Trial [J].
Lincoff, AM ;
Bittl, JA ;
Harrington, RA ;
Feit, F ;
Kleiman, NS ;
Jackman, JD ;
Sarembock, IJ ;
Cohen, DJ ;
Spriggs, D ;
Ebrahimi, R ;
Keren, G ;
Carr, J ;
Cohen, EA ;
Betriu, A ;
Desmet, W ;
Kereiakes, DJ ;
Rutsch, W ;
Wilcox, RG ;
de Feyter, PJ ;
Vahanian, A ;
Topol, EJ .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2003, 289 (07) :853-863