Noninvasive hemoglobin measurement using dynamic spectrum

被引:28
作者
Yi, Xiaoqing [1 ]
Li, Gang [1 ]
Lin, Ling [1 ,2 ]
机构
[1] Tianjin Univ, Sch Precis Instrument & Optoelect Engn, Tianjin 300072, Peoples R China
[2] Tianjin Univ, State Key Lab Precis Measurement Technol & Instru, Tianjin 300072, Peoples R China
关键词
COMPONENTS; ACCURACY;
D O I
10.1063/1.4998978
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Spectroscopy methods for noninvasive hemoglobin (Hgb) measurement are interfered by individual difference and particular weak signal. In order to address these problems, wehave put forward a series of improvement methods based on dynamic spectrum (DS), including instrument design, spectrum extraction algorithm, and modeling approach. The instrument adopts light sources composed of eight laser diodes with the wavelength range from 600 nm to 1100 nm and records photoplethysmography signals at eight wavelengths synchronously. In order to simplify the optical design, we modulate the light sources with orthogonal square waves and design the corresponding demodulation algorithm, instead of adopting a beam- splitting system. A newly designed algorithm named difference accumulation has been proved to be effective in improving the accuracy of dynamic spectrum extraction. 220 subjects are involved in the clinical experiment. An extreme learning machine calibration model between the DS data and the Hgb levels is established. Correlation coefficient and root-mean-square error of prediction sets are 0.8645 and 8.48 g/l, respectively. The results indicate that the Hgb level can be derived by this approach noninvasively with acceptable precision and accuracy. It is expected to achieve a clinic application in the future. Published by AIP Publishing.
引用
收藏
页数:8
相关论文
共 22 条
[1]   Photoplethysmography and its application in clinical physiological measurement [J].
Allen, John .
PHYSIOLOGICAL MEASUREMENT, 2007, 28 (03) :R1-R39
[2]   Non-invasive prediction of hemoglobin levels by principal component and back propagation artificial neural network [J].
Ding, Haiquan ;
Lu, Qipeng ;
Gao, Hongzhi ;
Peng, Zhongqi .
BIOMEDICAL OPTICS EXPRESS, 2014, 5 (04) :1145-1152
[3]  
Huang GB, 2004, IEEE IJCNN, P985
[4]   Extreme learning machine: Theory and applications [J].
Huang, Guang-Bin ;
Zhu, Qin-Yu ;
Siew, Chee-Kheong .
NEUROCOMPUTING, 2006, 70 (1-3) :489-501
[5]   Noninvasive total hemoglobin measurement [J].
Jeon, KJ ;
Kim, SJ ;
Park, KK ;
Kim, JW ;
Yoon, G .
JOURNAL OF BIOMEDICAL OPTICS, 2002, 7 (01) :45-50
[6]   An optical device to measure blood components by a photoplethysmographic method [J].
Kraitl, J ;
Ewald, H ;
Gehring, H .
JOURNAL OF OPTICS A-PURE AND APPLIED OPTICS, 2005, 7 (06) :S318-S324
[7]   A Multiple Biomedical Signals Synchronous Acquisition Circuit Based on Over-Sampling and Shaped Signal for the Application of the Ubiquitous Health Care [J].
Li, Gang ;
Liu, Jinzhen ;
Li, Xiaoxia ;
Lin, Ling ;
Wei, Rong .
CIRCUITS SYSTEMS AND SIGNAL PROCESSING, 2014, 33 (10) :3003-3017
[8]   Double-sampling to improve signal-to-noise ratio (SNR) of dynamic spectrum (DS) in full spectral range [J].
Li, Gang ;
Zhou, Mei ;
Lin, Ling .
OPTICAL AND QUANTUM ELECTRONICS, 2014, 46 (05) :691-698
[9]   Effect of Different Distribution of Components Concentration on the Accuracy of Quantitative Spectral Analysis [J].
Li Gang ;
Zhao Zhe ;
Wang Hui-quan ;
Lin Ling ;
Zhang Bao-ju ;
Wu Xiao-rong .
SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32 (07) :1905-1908
[10]   A novel algorithm combining oversampling and digital lock-in amplifier of high speed and precision [J].
Li, Gang ;
Zhou, Mei ;
He, Feng ;
Lin, Ling .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2011, 82 (09)