Detection and classification of gaseous microemboli during Pulsatile and nonpulsatile perfusion in a simulated neonatal CPB model

被引:29
作者
Uendar, Akif
Ji, Bingyang
Kunselman, Allen R.
Myers, John L.
机构
[1] Penn State Childrens Hosp, Penn State Milton S Hershey Med Ctr, Penn State Coll Med, Dept Pediat, Hershey, PA USA
[2] Penn State Childrens Hosp, Penn State Milton S Hershey Med Ctr, Penn State Coll Med, Dept Surg, Hershey, PA USA
[3] Penn State Childrens Hosp, Penn State Milton S Hershey Med Ctr, Penn State Coll Med, Dept Bioengn, Hershey, PA USA
[4] Penn State Childrens Hosp, Penn State Milton S Hershey Med Ctr, Penn State Coll Med, Dept Hlth Evaluat Sci, Hershey, PA USA
关键词
D O I
10.1097/MAT.0b013e3181588dc3
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We compared the effects of perfusion modes (pulsatile vs. nonpulsatile) on gaseous microemboli delivery using the Emboli Detection and Classification (EDACTM) Quantifier at postpump, postoxygenator, and postarterial filter sites in a simulated pediatric cardiopulmonary bypass (CPB) model. The mock loop was subjected to five different pump flow rates of equal 100 ml/min intervals, ranging from 400 to 800 ml/min. When the target pump flow rate was achieved, 5 cc air was introduced into the venous line. The EDACTM system recorded gaseous microemboli counts simultaneously at three locations in 5-minute intervals. Regardless of the type of perfusion mode, when the pump flow rate was increased, more gaseous microemboli were generated at postpump site. Compared with nonpulsatile flow, pulsatile flow did deliver significantly more gaseous microemboli at postpump site, but there was no difference between two groups at postoxygenator and postarterial filter sites. Capiox Baby-RX hollow-fiber membrane oxygenator significantly reduced the gaseous microemboli counts in both groups at all five pump flow rates with either pulsatile flow or nonpulsatile flow in this model. Our results suggest that using this novel EDAC (TM) system, we could detect the size of gaseous microemboli, as small as 10 mu m, and the percentage of detected gaseous microemboli, <40 mu m, was about 90% in total gaseous microemboli counts at any flow rate with pulsatile or nonpulsatile flow.
引用
收藏
页码:725 / 729
页数:5
相关论文
共 20 条
  • [1] Pulsatile ECM4 and VAD:: A dual use of a new device in pediatric cardiac patients
    Agati, Salvatore
    Ciccarello, Giuseppe
    Ocello, Salvatore
    Salvo, Dario
    Marcelletti, Carlo
    Uendar, Akif
    Mignosa, Carmelo
    [J]. ASAIO JOURNAL, 2006, 52 (05) : 501 - 504
  • [2] Effects of pulsatile and nonpulsatile perfusion on vital organ recovery in pediatric heart surgery:: A pilot clinical study
    Alkan, Tijen
    Akcevin, Atif
    Uendar, Akif
    Tuerkoglu, Halil
    Paker, Tufan
    Aytac, Aydin
    [J]. ASAIO JOURNAL, 2006, 52 (05) : 530 - 535
  • [3] A comparison of gaseous emboli release in five membrane oxygenators
    Beckley, Philip D.
    Shinko, Paul D.
    Sites, Jeffrey P.
    [J]. PERFUSION-UK, 1997, 12 (02): : 133 - 141
  • [4] Neuropsychologic impairment after coronary bypass surgery: Effect of gaseous microemboli during perfusionist interventions
    Borger, MA
    Peniston, CM
    Weisel, RD
    Vasiliou, M
    Green, REA
    Feindel, CM
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2001, 121 (04) : 743 - 749
  • [5] Can an oxygenator design potentially contribute to air embolism in cardiopulmonary bypass? A novel method for the determination of the air removal capabilities of neonatal membrane oxygenators
    De Somer, F.
    Dierickx, P.
    Dujardin, D.
    Verdonck, P.
    Van Nooten, G.
    [J]. PERFUSION-UK, 1998, 13 (03): : 157 - 163
  • [6] An evaluation of the benefits of pulsatile versus nonpulsatile perfusion during cardiopulmonary bypass procedures in pediatric and adult cardiac patients
    Ji, Bingyang
    Uendar, Akif
    [J]. ASAIO JOURNAL, 2006, 52 (04) : 357 - 361
  • [7] 'Does vacuum-assisted venous drainage increase gaseous microemboli during cardiopulmonary bypass?
    Jones, TJ
    Deal, DD
    Vernon, JC
    Blackburn, N
    Stump, DA
    [J]. ANNALS OF THORACIC SURGERY, 2002, 74 (06) : 2132 - 2137
  • [8] Bubbles and bypass: an update
    Kurusz, M
    Butler, BD
    [J]. PERFUSION-UK, 2004, 19 : S49 - S55
  • [9] Kurusz Mark, 1993, P267
  • [10] Bubble generation and venous air filtration by hard-shell venous reservoirs: a comparative study
    Mitchell, S. J.
    Willcox, T.
    Gorman, D. F.
    [J]. PERFUSION-UK, 1997, 12 (05): : 325 - 333