Background and study aims: Contrast-enhanced ultrasonography (CEUS) has increased considerably the use of ultrasound for hemodynamical analyses and quantification. Bolus injection of microbubble agents is used to evaluate transit times. This study aimed to determine the diagnostic accuracy of arrival time (seconds) to the hepatic artery (HAAT), hepatic vein (HVAT), and portal vein (PVAT), based on CEUS used for the diagnosis of cirrhosis, and to correlate these arrival times with the liver stiffness and disease severity. Patients and methods: This study evaluated 29 HCV cirrhotic and 19 chronic hepatitis C patients. History, clinical examination, laboratory investigations, abdominal ultrasonography, point shear-wave elastography (pSWE), and CEUS were conducted. Results: The mean liver stiffness increased significantly in cirrhotic versus chronic HCV (22.7 versus 5.1; p-value < 0.001). The mean HAAT (pvalue = 0.001), PVAT (p-value = 0.002), and HVAT values (p-value: 0.001) were significantly prolonged in cirrhotic compared with chronic HCV. The HVAT cut-off point of cirrhotic patients was 18 s with a sensitivity, specificity, and accuracy of 96.6%, 63.2%, and 83.3%, respectively (area under curve: 0.801). Significant positive correlation was found between liver stiffness (kPa) and HVAT (s) (r = 0.585; pvalue = 0.005). No significant correlation was detected between HVAT (s) and the severity of liver disease, as assessed by the Child or MELD scores in cirrhotic patients. Conclusion: Measuring HVAT by CEUS yielded high-accuracy and correlation outcomes for cirrhosis detection. It could be a valuable noninvasive method for the diagnosis of cirrhosis.(c) 2022 Pan-Arab Association of Gastroenterology. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:195 / 200
页数:6
相关论文
共 28 条
  • [1] Hepatic Vein Arrival Time for Diagnosis of Liver Cirrhosis A 10-Year Single-Center Experience With Contrast-Enhanced Sonography
    Abbattista, Teresa
    Ridolfi, Francesco
    Consalvo, Giovanni Traina
    Brunelli, Eugenio
    [J]. JOURNAL OF ULTRASOUND IN MEDICINE, 2016, 35 (10) : 2121 - 2128
  • [2] Non-invasive diagnosis of hepatic cirrhosis by transit-time analysis of an ultrasound contrast agent
    Albrecht, T
    Blomley, MJK
    Cosgrove, DO
    Taylor-Robinson, SD
    Jayaram, V
    Eckersley, R
    Urbank, A
    Butler-Barnes, J
    Patel, N
    [J]. LANCET, 1999, 353 (9164) : 1579 - 1583
  • [3] Ultrasound imaging with SonoVue: Low mechanical index real-time imaging
    Bauer, A
    Solbiati, L
    Weissman, N
    [J]. ACADEMIC RADIOLOGY, 2002, 9 : S282 - S284
  • [4] Science, medicine, and the future - Microbubble contrast agents: a new era in ultrasound
    Blomley, MJK
    Cooke, JC
    Unger, EC
    Monaghan, MJ
    Cosgrove, DO
    [J]. BMJ-BRITISH MEDICAL JOURNAL, 2001, 322 (7296): : 1222 - 1225
  • [5] Liver microbubble transit time compared with histology and Child-Pugh score in diffuse liver disease: a cross sectional study
    Blomley, MJK
    Lim, AKP
    Harvey, CJ
    Patel, N
    Eckersley, RJ
    Basilico, R
    Heckemann, R
    Urbank, A
    Cosgrove, DO
    Taylor-Robinson, SD
    [J]. GUT, 2003, 52 (08) : 1188 - 1193
  • [6] Detection of Hepatic Metastases from Colorectal Cancer: Prospective Evaluation of Gray Scale US Versus SonoVue® Low Mechanical Index Real Time-Enhanced US as Compared with Multidetector-CT or Gd-BOPTA-MRI
    Cantisani, V.
    Ricci, P.
    Erturk, M.
    Pagliara, E.
    Drudi, F.
    Calliada, F.
    Mortele, K.
    D'Ambrosio, U.
    Marigliano, C.
    Catalano, C.
    Marin, D.
    Di Seri, M.
    Longo, F.
    Passariello, R.
    [J]. ULTRASCHALL IN DER MEDIZIN, 2010, 31 (05): : 500 - 505
  • [7] First-Pass Arrival Interval of Ultrasound Contrast Medium in the Hepatic Artery and Portal Vein as a Marker for Assessment of Liver Transplant Recipients
    Chang, Nai-Wen
    Wang, Hsin-Kai
    Liu, Chin-Su
    Loong, Che-Chuan
    Lai, Yi-Chen
    Chiou, Hong-Jen
    Chou, Yi-Hong
    [J]. TRANSPLANTATION PROCEEDINGS, 2021, 53 (07) : 2329 - 2334
  • [8] Guidelines and good clinical practice recommendations for contrast enhanced ultrasound (CEUS) -: Update 2008
    Claudon, M.
    Cosgrove, D.
    Albrecht, T.
    Bolondi, L.
    Bosio, M.
    Calliada, F.
    Correas, J. -M.
    Darge, K.
    Dietrich, C.
    D'Onofrio, M.
    Evans, D. H.
    Filice, C.
    Greiner, L.
    Jaeger, K.
    de Jong, N.
    Leen, E.
    Lencioni, R.
    Lindsell, D.
    Martegani, A.
    Meairs, S.
    Nolsoe, C.
    Piscaglia, F.
    Ricci, P.
    Seidel, G.
    Skjoldbye, B.
    Solbiati, L.
    Thorelius, L.
    Tranquart, F.
    Weskott, H. P.
    Whittingham, T.
    [J]. ULTRASCHALL IN DER MEDIZIN, 2008, 29 (01): : 28 - 44
  • [9] Accuracy and reliability of microbubble ultrasound measurements for the non-invasive assessment of hepatic fibrosis in chronic hepatitis C
    Cobbold, Jeremy F. L.
    Patel, Dhupal
    Fitzpatrick, Julie A.
    Patel, Nayna
    Crossey, Mary M. E.
    AbdAlla, Mohamed Saad
    Goldin, Robert D.
    Vennart, William
    Thomas, Howard C.
    Taylor-Robinson, Simon D.
    [J]. HEPATOLOGY RESEARCH, 2012, 42 (05) : 515 - 522
  • [10] Intrahepatic peripheral cholangiocarcinoma (IPCC):: comparison between perfusion ultrasound and CT imaging
    D'Onofrio, M.
    Vecchiato, E.
    Canfisani, V.
    Barbi, E.
    Passamonti, M.
    Ricci, P.
    Malago, R.
    Faccioli, N.
    Zamboni, G.
    Mucelli, R. Pozzi
    [J]. RADIOLOGIA MEDICA, 2008, 113 (01): : 76 - 86