A Modified Manta Ray Foraging Optimizer for Planning Inverter-Based Photovoltaic With Battery Energy Storage System and Wind Turbine in Distribution Networks

被引:20
|
作者
Abdel-Mawgoud, H. [1 ]
Ali, Abdelfatah [2 ]
Kamel, Salah [1 ]
Rahmann, Claudia [3 ]
Abdel-Moamen, M. A. [4 ]
机构
[1] Aswan Univ, Dept Elect Engn, Fac Engn, Aswan 81542, Egypt
[2] South Valley Univ, Dept Elect Engn, Fac Engn, Qena 83523, Egypt
[3] Univ Chile, Dept Elect Engn, Santiago 80000, Chile
[4] Aswan Univ, Fac Energy Engn, Dept Elect Engn, Aswan 81528, Egypt
来源
IEEE ACCESS | 2021年 / 9卷
关键词
Optimization; Batteries; Power generation; Load modeling; Inverters; Reactive power; Wind turbines; Battery energy storage; distribution network; Manta ray foraging optimization; optimization; photovoltaic; uncertainty; wind turbine; RENEWABLE ENERGY; OPTIMAL ALLOCATION; HYBRID SYSTEM; PV; INTEGRATION; GENERATORS; DISPATCH; SOLAR; ELECTRIFICATION; RECONFIGURATION;
D O I
10.1109/ACCESS.2021.3092145
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
It is widely accepted that the integration of natural sources in distribution networks is becoming more attractive as they are sustainable and nonpolluting. This paper firstly proposes a modified Manta Ray Foraging Optimizer (MMRFO) to enhance the characteristic of MRFO technique. The modified MRFO technique is based on inserting the Simulated Annealing technique into the original MRFO to enhance the exploitation phase which is responsible for finding the promising region in the search area. Secondly, the developed technique is utilized for determining the best sizes and locations of multiple wind turbine (WT) and photovoltaic (PV) units in Radial Distribution System (RDS). The total system loss is taken as single-objective function to be minimized, considering the probabilistic nature of PV and WT output generation with variable load demand. Reactive loss sensitivity factor (QLSF) is utilized for obtaining the candidate locations up to fifty percent of total system buses with the aim of reducing the search space. Battery Energy Storage System (BESS) is used with PV to change it into a dispatchable supply. The changes in system performance by optimally integrating PV and WT alone or together are comprehensively studied. The proposed solution approach is applied for solving the standard IEEE 69 bus RDS. The obtained results demonstrate that installing PV and WT simultaneously achieves superior results than installing PV alone and WT alone in RDS. Further, simultaneous integration of WT and PV with BESS gives better results than simultaneous integration of WT and PV without BESS in RDS. The simulation results prove that the total system losses can be reduced by enabling the reactive power capability of PV inverters. The convergence characteristic shows that the modified MRFO gives the best solutions compared with the original MRFO algorithm.
引用
收藏
页码:91062 / 91079
页数:18
相关论文
共 34 条
  • [31] A multiple uncertainty-based Bi-level expansion planning paradigm for distribution networks complying with energy storage system functionalities
    Zhou, Siyu
    Han, Yang
    Chen, Shuheng
    Yang, Ping
    Mahmoud, Karar
    Darwish, Mohamed M. F.
    Matti, Lehtonen
    Zalhaf, Amr S.
    ENERGY, 2023, 275
  • [32] Multi-Agent-Based Voltage Regulation Scheme for High Photovoltaic Penetrated Active Distribution Networks Using Battery Energy Storage Systems
    Zhang, Yongxi
    Meng, Ke
    Luo, Fengji
    Yang, Hongming
    Zhu, Jiahua
    Dong, Zhao Yang
    IEEE ACCESS, 2020, 8 : 7323 - 7333
  • [33] Design of a stand-alone hybrid Photovoltaic-Wind generating system with battery storage - Energy based modeling with losses integration - Energy management control strategy
    Dali, Mehdi
    Belhadj, Jamel
    Roboam, Xavier
    JOURNAL OF ELECTRICAL SYSTEMS, 2008, 4 (03)
  • [34] Day-ahead dispatch strategy for integrated system of wind/photovoltaic/pumped-storage/gas-turbine-power/energy storage based on multi-frequency scale of PWP
    Ma, Jing
    Ding, Xiuxiang
    Shi, Jianlei
    Huang, Tianyi
    Wang, Zengping
    INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2015, 25 (08): : 1603 - 1620