Study on Transient Overvoltage of Offshore Wind Farm Considering Different Electrical Characteristics of Vacuum Circuit Breaker

被引:4
|
作者
Zhou, Zikai [1 ]
Guo, Yaxun [1 ]
Jiang, Xiaofeng [2 ]
Liu, Gang [1 ]
Tang, Wenhu [1 ]
Deng, Honglei [1 ]
Li, Xiaohua [1 ]
Zheng, Ming [3 ]
机构
[1] South China Univ Technol, Sch Elect Power Engn, Guangzhou 510640, Guangdong, Peoples R China
[2] Guangdong Power Grid Co Ltd, Jieyang Power Supply Bur, Jieyang 522000, Peoples R China
[3] Guangdong Elect Power Design Inst Co Ltd, China Energy Engn Grp, Guangzhou 510663, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
offshore wind farm; vacuum circuit breaker; reignition characteristics; switching overvoltage;
D O I
10.3390/jmse7110415
中图分类号
U6 [水路运输]; P75 [海洋工程];
学科分类号
0814 ; 081505 ; 0824 ; 082401 ;
摘要
For the study of transient overvoltage (TOV) in an offshore wind farm (OWF) collector system caused by switching off vacuum circuit breakers (VCBs), a simplified experimental platform of OWF medium-voltage (MV) cable collector system was established in this paper to conduct switching operation tests of VCB and obtain the characteristic parameters for VCB, especially dielectric strength parameters; also, the effectiveness of the VCB reignition model was verified. Then, PSCAD/EMTDC was used to construct the MV collector system of the OWF, and the effects of normal switching and fault switching on TOV amplitude, steepness, and the total number of reignition of the VCB were studied, respectively, with the experimental parameters and traditional parameters of dielectric strength of the VCB. The simulation results show that when the VCB is at the tower bottom, the overvoltage amplitude generated by the normal switching is the largest, which is 1.83 p.u., and the overvoltage steepness of the fault switching is the largest, up to 142 kV/mu s. The overvoltage amplitude and steepness caused by switching off VCB at the tower bottom faultily with traditional parameters are about 2 and 1.5 times of the experimental parameters under the same operating condition.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] Collaborative emergency defense strategy for offshore wind farm clusters considering the spatial-temporal characteristics of a typhoon
    Lu R.
    Xiong X.
    Chen H.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2024, 52 (12): : 13 - 24
  • [42] Study on transient recovery voltage distribution mechanism and grading capacitor of double-break vacuum circuit breaker
    Shu, Shengwen
    Ruan, Jiangjun
    Huang, Daochun
    Wu, Gaobo
    Liu, Chang
    Dianwang Jishu/Power System Technology, 2012, 36 (11): : 252 - 259
  • [43] Study on Transient Recovery Voltage Distribution Mechanism and Grading Capacitor of Double-Break Vacuum Circuit Breaker
    Shu, Shengwen
    Ruan, Jiangjun
    Huang, Daochun
    Wu, Gaobo
    Liu, Chang
    25TH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM (ISDEIV 2012), 2012, : 501 - 504
  • [44] Transformer Switching With Vacuum Circuit Breaker: Case Study of PV Inverter LC Filters Impact on Transient Overvoltages
    Kuczek, T.
    Florkowski, M.
    Piasecki, W.
    IEEE TRANSACTIONS ON POWER DELIVERY, 2016, 31 (01) : 44 - 49
  • [45] Feature Analysis for Transient Overvoltage in Offshore Wind Farm Based on High and Low Frequency Energy Rate Using Multi-scale Mathematical Morphology
    Gu Y.
    Tang W.
    Xin Y.
    Zhou J.
    Wu Q.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2021, 41 (05): : 1702 - 1712
  • [46] Simulation study on the transient operational performances of a wind farm including different wind turbine generator systems
    Li, Hui
    Zhao, Bin
    Shi, Xu-Yang
    Wang, He-Sheng
    Yang, Chao
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2011, 39 (13): : 1 - 7
  • [47] Assessment of offshore wind farm characteristics with the cloud resolving storm simulator: A case study in Japan
    Raak, Fredrik
    Susuki, Yoshihiko
    Tsuboki, Kazuhisa
    Kato, Masaya
    Eguchi, Shinya
    Hikihara, Takashi
    WIND ENERGY, 2018, 21 (07) : 531 - 543
  • [48] Investigation on arc characteristics in cup-shaped contacts with different structure for transverse magnetic field vacuum circuit breaker
    Wei, Leming
    Xiu, Shixin
    Jiang, Yuzi
    Yuan, Bo
    Qu, Chenchen
    Yang, Jinwang
    CONTRIBUTIONS TO PLASMA PHYSICS, 2022, 62 (01)
  • [49] Transient Interaction Study for VSC-HVDC connected Offshore Wind Park considering original Controls
    Teeuwsen, Simon P.
    Zurowski, Rainer
    Cai, Li-Jun
    Jensen, Simon
    Osmanbasic, Adnan
    Gafaro, Francisco
    2014 IEEE PES GENERAL MEETING - CONFERENCE & EXPOSITION, 2014,
  • [50] Study of vacuum circuit breaker performance and weld formation for different drive closing speeds for switching capacitive current
    Delachaux, T.
    Rager, F.
    Gentsch, D.
    ISDEIV 2010: XXIVTH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM, 2010, : 240 - 243