Dose reduction at CT of the lumbar spine using a 320-detector row scanner: initial results

被引:10
作者
Gervaise, A. [1 ]
Louis, M. [1 ]
Batch, T. [1 ]
Loeuille, D. [2 ]
Noel, A. [3 ]
Guillemin, F. [4 ]
Blum, A. [1 ]
机构
[1] CHU Nancy, Hop Cent, Serv Imagerie Guilloz, F-54035 Nancy, France
[2] CHU Nancy, Hop Brabois, Serv Rhumatol, F-54511 Vandoeuvre Les Nancy, France
[3] Nancy Univ, CNRS, CRAN UMR 7039, Unite Radiophys Med,Ctr Alexis Vautrin, F-54511 Vandoeuvre Les Nancy, France
[4] CHU Nancy, Epidemiol & Evaluat Clin, INSERM, CIC EC, F-54511 Vandoeuvre Les Nancy, France
来源
JOURNAL DE RADIOLOGIE | 2010年 / 91卷 / 7-8期
关键词
CT; 320-detector row; Dose; Reduction; Lumbar spine; COMPUTED-TOMOGRAPHY EXAMINATIONS; CONE-BEAM CT; IONIZING-RADIATION; CANCER-RISKS; EXPOSURE; QUALITY; IMPLEMENTATION; RELIABILITY; PAIN;
D O I
10.1016/S0221-0363(10)70115-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose. To compare radiation dose and image quality for CT of the lumbar spine between helical CT and wide volume mode scanning with a 320-detector row CT. Patients and methods. Monocenter prospective study on 20 consecutive patients divided into two groups. All 20 patients underwent lumbar spine CT on the 320-detector row scanner (Aquilion One, Toshiba). The CT examinations for group I were performed using the wide volume mode with 320 detector rows while the CT examinations for group 2 were performed using a 64-detector row helical CT mode. The acquisition length and delivered close corresponding to the DLPe (extended close length product) as well as qualitative and quantitative image quality were compared between both groups. Results. The mean acquisition length was comparable between both groups. There was a significant close reduction of about 35% for group I compared to group 2 (mean DLPe of 970 mGy.cm for group I compared to 1503 mGy.cm for group 2, p<0.028) when using the wide volume mode acquisition at 320-detector row CT compared to the 64-detector row helical CT mode. No significant difference was noted for image quality between both groups. Conclusion. The acquisition of lumbar CT using the wide volume mode at 320-detector row CT allows significant dose reduction to patients compared to the 64-detector row helical CT mode while preserving image quality.
引用
收藏
页码:779 / 785
页数:7
相关论文
共 53 条
[1]  
[Anonymous], J OFFICIEL REPUBLIQU
[2]  
[Anonymous], 2006, HLTH RISKS EXP LOW L
[3]  
[Anonymous], 2009, 606012442009 IEC, V3rd
[4]  
[Anonymous], 2007, Journal Officiel de la Republique Francaise z dnia
[5]   Lumbar Spine: Agreement in the Interpretation of 1.5-T MR Images by Using the Nordic Modic Consensus Group Classification Form [J].
Arana, Estanislao ;
Royuela, Ana ;
Kovacs, Francisco M. ;
Estremera, Ana ;
Sarasibar, Helena ;
Amengual, Guillermo ;
Galarraga, Isabel ;
Martinez, Carmen ;
Muriel, Alfonso ;
Abraira, Victor ;
Teresa Gil del Real, Maria ;
Zamora, Javier ;
Campillo, Carlos .
RADIOLOGY, 2010, 254 (03) :809-817
[6]   Radiation Exposure from Musculoskeletal Computerized Tomographic Scans [J].
Biswas, Debdut ;
Bible, Jesse E. ;
Bohan, Michael ;
Simpson, Andrew K. ;
Whang, Peter G. ;
Grauer, Jonathan N. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (08) :1882-1889
[7]  
Blum A, 2007, RAD DOSE ADULT PEDIA, P185
[8]  
BLUM A, 2002, SCANOGRAPHIE VOLUMIQ, P39
[9]  
Boos N, 1996, Eur Spine J, V5, P2, DOI 10.1007/BF00307823
[10]   Cancer risks attributable to low doses of ionizing radiation: Assessing what we really know [J].
Brenner, DJ ;
Doll, R ;
Goodhead, DT ;
Hall, EJ ;
Land, CE ;
Little, JB ;
Lubin, JH ;
Preston, DL ;
Preston, RJ ;
Puskin, JS ;
Ron, E ;
Sachs, RK ;
Samet, JM ;
Setlow, RB ;
Zaider, M .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2003, 100 (24) :13761-13766