On-column derivatization using redox activity of porous graphitic carbon stationary phase: An approach to enhancement of separation selectivity of liquid chromatography

被引:29
|
作者
Shibukawa, M
Unno, A
Miura, T
Nagoya, A
Oguma, K
机构
[1] Nihon Univ, Coll Ind Technol, Dept Appl Mol Chem, Narashino, Chiba 2758575, Japan
[2] Chiba Univ, Fac Engn, Dept Mat Technol, Chiba 2638522, Japan
[3] Japan Chem Anal Ctr, Inage, Chiba 2630002, Japan
关键词
D O I
10.1021/ac020705e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new on-column derivatization method based on the redox activity of porous graphitic carbon (PGC) packing materials was presented for enhancement of separation selectivity of HPLC. Two PGC packing materials were used as the solid redox agents as well as the stationary phase, and their redox activities were investigated using trans-1,2-diaminocyclohexanetetraacetate (DCTA) complexes of some metal ions as probe compounds. It was found that the redox property of PGC was modified by treating them with a solution containing a reducing agent, sodium sulfite or hydroxylammonium chloride. The original PGC packings oxidized Co(II)-DCTA to Co(III)DCTA during elution, while the PGC treated with a reducing agent showed reduction activity converting Co(III)-DCTA to Co(II)-DCTA. These two cobalt complexes do not form their individual chromatographic zones but migrate as a single zone of their mixture on the PGC column contrary to the chromatographic behavior on a C-18 bonded silica, on which Co(II)-DCTA and Co(III)-DCTA can be separated. Treatment of the PGC column with a reducing agent solution transforms the oxidative activity of the original PGC packing to a reductive one from the upper part of the column, so that the retention time of the cobalt complex can be controlled by changing the volume of the reducing agent solution to be used for treatment of the PGC column. The selective separation and determination of cobalt in a reference manganese nodule sample by the developed method was demonstrated.
引用
收藏
页码:2775 / 2783
页数:9
相关论文
共 50 条
  • [31] High performance liquid chromatography of acarbose and its metabolite on porous graphitic carbon column
    Daali, Y
    Cherkaoui, S
    Cahours, X
    Varesio, E
    Veuthey, JL
    JOURNAL OF SEPARATION SCIENCE, 2002, 25 (5-6): : 280 - 284
  • [32] DETERMINATION OF HISTAMINE AND 1-METHYLHISTAMINE BY LIQUID-CHROMATOGRAPHY USING ON-COLUMN DERIVATIZATION AND A COLUMN-SWITCHING TECHNIQUE
    SAITO, K
    YAMADA, F
    HORIE, M
    NAKAZAWA, H
    ANALYTICAL SCIENCES, 1993, 9 (06) : 803 - 806
  • [33] On-line redox derivatization liquid chromatography using double separation columns and one derivatization unit
    Saitoh, K
    Yamada, N
    Ishikawa, E
    Nakajima, H
    Shibukawa, M
    JOURNAL OF SEPARATION SCIENCE, 2006, 29 (01) : 49 - 56
  • [34] Redox reaction catalyzed by a porous graphite carbon packing and its application to selectivity enhancement of high-performance liquid chromatography separation of metal complexes
    Shibukawa, M
    Unno, A
    Oyashiki, Y
    Miura, T
    Nagoya, A
    Oguma, K
    ANALYTICAL COMMUNICATIONS, 1997, 34 (12): : 397 - 400
  • [35] EFFECTS OF THE STATIONARY PHASE IN ON-COLUMN FLUOROMETRIC DETECTION IN MICRO HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    TAKEUCHI, T
    ISHII, D
    JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1988, 11 (11): : 841 - 843
  • [36] SIGNAL ENHANCEMENT BY ON-COLUMN FLUOROMETRIC DETECTION IN MICROCOLUMN LIQUID-CHROMATOGRAPHY WITH CYCLODEXTRIN-BONDED STATIONARY PHASES
    TAKEUCHI, T
    MIWA, T
    CHROMATOGRAPHIA, 1994, 38 (9-10) : 555 - 558
  • [37] Separation of Triacylglycerols from Edible Oil Using a Liquid Chromatography-Mass Spectrometry System with a Porous Graphitic Carbon Column and a Toluene-Isopropanol Gradient Mobile Phase
    Zhang, Shi-Ding
    Gong, Can
    Lu, Yan
    Xu, Xu
    JOURNAL OF THE AMERICAN OIL CHEMISTS SOCIETY, 2018, 95 (10) : 1253 - 1266
  • [38] Separations of benzodiazepines using electrochemically modulated liquid chromatography - Efficient separations from changes in the voltage applied to a porous graphitic carbon stationary phase
    Ting, EY
    Porter, MD
    JOURNAL OF CHROMATOGRAPHY A, 1998, 793 (01) : 204 - 208
  • [39] SELECTIVITY OF STATIONARY PHASE IN SEPARATION OF NORMAL-OLEFINS BY GAS-LIQUID CHROMATOGRAPHY
    BUTEIKO, ZF
    KOROL, AN
    PETROLEUM CHEMISTRY, 1969, 9 (03) : 217 - &
  • [40] Determination of the Enantiomeric Purity of Trelagliptin by Pre-Column Derivatization and Liquid Chromatography on a Chiral Stationary Phase
    Qi Wang
    Xiuli Chen
    Cuiwei Zhang
    Mengya Liao
    Mingxing Hu
    Shuo Lin
    Yongmei Xie
    Wenya Yin
    Yiwen Zhang
    Chromatographia, 2015, 78 : 1395 - 1400