Microstructural Effect Limitations in the Analysis of SnAg, SnBi and SnIn Lead-free Solders by Wavelength Dispersion X-Ray Spectrometry

被引:2
作者
Gorewoda, Tadeusz [1 ]
Mzyk, Zofia [1 ]
Anyszkiewicz, Jacek [1 ]
Bilewska, Katarzyna [1 ]
Cybulski, Andrzej [1 ]
Golebiewska-Kurzawska, Joanna [1 ]
Knapik, Magdalena [1 ]
Kostrzewa, Justyna [1 ]
Grzegorczyk, Magdalena [1 ]
Malara, Szymon [1 ]
机构
[1] Inst Nonferrous Met, PL-44100 Gliwice, Poland
关键词
X-ray fluorescence spectrometry; sample preparation; re-melting; lead-free solder; XRF;
D O I
10.1134/S1061934820010086
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This article describes the effects of microstructures in an analysis of lead-free solders, namely SnAg, SnBi and SnIn, using X-ray fluorescence spectrometry (XRF). The size of the microstructures in the samples and calibration materials has a strong impact on the calibration accuracy and results. A comparison of the microstructure size and critical thickness values demonstrated the importance of the former parameter in terms of the analyzed volume of the specimen. The re-melting and casting in an induction furnace at developed conditions were determined to be a way to obtain samples with fine-grained microstructures. Calibration with re-melted reference materials yielded more accurate calibration curves than calibration using the materials in their original state. Re-melting of the samples resulted in improvements in the XRF results in comparison to the reference values. This improvement is especially important in case of alloying elements with concentrations that determine the recognition of a specific solder grade.
引用
收藏
页码:56 / 62
页数:7
相关论文
共 13 条
[1]   Lead-free solders in microelectronics [J].
Abtew, M ;
Selvaduray, G .
MATERIALS SCIENCE & ENGINEERING R-REPORTS, 2000, 27 (5-6) :95-141
[2]  
[Anonymous], 2011, OFFICIAL J EUROPEA L
[3]  
[Anonymous], 2017, XRAY MASS ATT COEFF
[4]  
Bath J., 2013, SMT MAG, V28, P12
[5]  
Beckhoff B., 2006, HDB PRACTICAL XRAY F
[6]  
Bertin E.P., 1975, Principles and Practice of X-ray Spectrometric Analysis
[7]   Synthesis and melting behaviour of Bi, Sn and Sn-Bi nanostructured alloy [J].
Frongia, F. ;
Pilloni, M. ;
Scano, A. ;
Ardu, A. ;
Cannas, C. ;
Musinu, A. ;
Borzone, G. ;
Delsante, S. ;
Novakovic, R. ;
Ennas, G. .
JOURNAL OF ALLOYS AND COMPOUNDS, 2015, 623 :7-14
[8]   Determination of bromine in selected polymer materials by a wavelength-dispersive X-ray fluorescence spectrometric method - Critical thickness problem and solutions [J].
Gorewoda, Tadeusz ;
Mzyk, Zofia ;
Anyszkiewicz, Jacek ;
Charasinska, Jadwiga .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2015, 106 :8-12
[9]   The development of correct methods for Sn-Pb solder analysis by wavelength dispersion X-ray fluorescence spectrometry [J].
Gorewoda, Tadeusz ;
Anyszkiewicz, Jacek ;
Mzyk, Zofia ;
Buzek, Lucja .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2014, 92 :29-33
[10]  
ISO, 2014, 94532014 ISO