A sliding hip screw augmented with 2 screws is biomechanically similar to an inverted triad of cannulated screws in repair of a Pauwels type-III fracture

被引:47
作者
Kemker, B. [1 ]
Magone, K. [1 ]
Owen, J. [1 ]
Atkinson, P. [1 ,2 ]
Martin, S. [1 ]
Atkinson, T. [1 ,2 ]
机构
[1] McLaren Hosp, 401 S Ballenger, Flint, MI 48532 USA
[2] Kettering Univ, 1700 Univ Ave, Flint, MI 48504 USA
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2017年 / 48卷 / 08期
关键词
Femur fracture; Femoral neck fracture; Pauwells III; Sliding hip screw; Dynamic hip screw; Cannulated triad; Sawbones; Hip biomechanics; FEMORAL-NECK FRACTURES; INTERNAL-FIXATION; SYNTHETIC BONE; MECHANICAL ANALYSIS; COMPOSITE FEMURS; YOUNG-ADULTS; CASE SERIES; PLATE; COMPLICATIONS; CONFIGURATION;
D O I
10.1016/j.injury.2017.05.013
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: Pauwels III femoral neck fractures are highly unstable. These fractures are commonly treated with three cannulated screws or sliding hip screw (SHS) implants, however high rates of non-union persist. A hybrid SHS construct has recently been proposed. The objective of the study was to compare this construct to the familiar inverted triad of cannulated screws and to a single SHS. Methods: Fourth generation biomechanical femur analogs were used to create a highly repeatable injury model. The hybrid SHS construct contained a SHS with two superior cannulated screws in an inverted triangle configuration. Eight samples for each construct were biomechanically evaluated and the results compared using ANOVA (p < 0.05). Results: The cannulated triad and hybrid SHS provided similar stiffness and fracture gap motion. The single SHS exhibited significantly lower stiffness and larger fracture plane diastasis than either the inverted triangle of cannulated screws or hybrid SHS (p < 0.05). None of the constructs exhibited catastrophic failure during cyclic loading nor under loading up to 2.5 times body weight. Conclusions: The single SHS provided the least stable fracture fixation, while the inverted triad and hybrid SHS constructs were mechanically similar. The fracture repair simulated here illustrates how these repairs have the potential to return near pre-fracture strength in ideal conditions with young, healthy bone. However; in clinical situations where comminution impairs load transfer through the cortices the hybrid SHS may be the most favorable option. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1743 / 1748
页数:6
相关论文
共 48 条
[1]   Vertically oriented femoral neck fractures: Mechanical analysis of four fixation techniques [J].
Aminian, Arash ;
Gao, Fan ;
Fedoriw, Wasyl W. ;
Zhang, Li-Qun ;
Kalainov, David M. ;
Merk, Bradley R. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2007, 21 (08) :544-548
[2]   INTRACAPSULAR FRACTURES OF THE FEMORAL-NECK - RESULTS OF CANNULATED SCREW FIXATION [J].
ASNIS, SE ;
WANEKSGAGLIONE, L .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1994, 76A (12) :1793-1803
[3]   Pauwels' classification of femoral neck fractures:: Correct interpretation of the original [J].
Bartonícek, J .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2001, 15 (05) :358-360
[4]   A biomechanical comparison of composite femurs and cadaver femurs used in experiments on operated hip fractures [J].
Basso, Trude ;
Klaksvik, Jomar ;
Syversen, Unni ;
Foss, Olav A. .
JOURNAL OF BIOMECHANICS, 2014, 47 (16) :3898-3902
[5]   Hip contact forces and gait patterns from routine activities [J].
Bergmann, G ;
Deuretzbacher, G ;
Heller, M ;
Graichen, F ;
Rohlmann, A ;
Strauss, J ;
Duda, GN .
JOURNAL OF BIOMECHANICS, 2001, 34 (07) :859-871
[6]   Optimal Internal Fixation for Femoral Neck Fractures: Multiple Screws or Sliding Hip Screws? [J].
Bhandari, Mohit ;
Tornetta, Paul, III ;
Hanson, Beate ;
Swiontkowski, Marc F. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2009, 23 (06) :403-407
[7]  
Bonnaire FA, 2002, INJURY, V33, pS47
[8]  
Browner BD, 2015, SKELETAL TRAUMA BASI, V2, P1640
[9]   Complications after intracapsular hip fractures in young adults - A meta-analysis of 18 published studies involving 564 fractures [J].
Damany, DS ;
Parker, MJ ;
Chojnowski, A .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2005, 36 (01) :131-141
[10]   TREATMENT OF FRACTURES OF FEMORAL-NECK BY REPLACEMENT WITH THOMPSON PROSTHESIS [J].
DARCY, J ;
DEVAS, M .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1976, 58 (03) :279-286