Exposure assessment of PM2.5 in temple premises and crematoriums in Kanpur, India

被引:15
作者
Bhadauria, Vishal [1 ]
Parmar, Dipteek [1 ]
Ganguly, Rajiv [1 ]
Rathi, Abhinav Kumar [1 ]
Kumar, Prashant [2 ]
机构
[1] Harcourt Butler Tech Univ, Dept Civil Engn, Kanpur 208002, Uttar Pradesh, India
[2] Univ Surrey, Fac Engn & Phys Sci, Global Ctr Clean Air Res GCARE, Dept Civil & Environm Engn, Guildford GU2 7XH, Surrey, England
关键词
PM2; 5; Temples; Crematorium; Air quality; Exposure assessment; Deposition dose; PARTICULATE AIR-POLLUTION; HUMAN HEALTH-RISKS; YUN-YEN TEMPLE; SOURCE REGIONS; AMBIENT AIR; INCENSE; PARTICLES; INDOOR; MATTER; QUALITY;
D O I
10.1007/s11356-022-18739-5
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Regular use of incense and earthen lamps in temples leads to the release of particulate matter (PM), airborne flecks, and gaseous pollutants. Similarly, the cremation of dead bodies using timber and other accessories such as incense, organic chemicals containing carbon, and clothes generates air pollutants. It is currently unclear how much emissions and exposure these activities may lead. This work attempts to fill this gap in our understanding by assessing the associated emissions of PM2.5 and the corresponding exposure. Ten temples and two cremation grounds were considered for the sampling of PM2.5. The average PM2.5 concentration at the ten temples and the two crematoriums was found to be 658.30 +/- 112.63 mu g/m(3) and 1043.50 +/- 191.63 mu g/m(3), respectively. The range of real-time PM2.5 data obtained from the nearest twelve stations located in the vicinity was 113-191 mu g/m(3). The exposure assessment in terms of deposition dose was carried out using the ICRP model. The maximum and minimum total respiratory deposition dose rate for PM2.5 for temples was 175.75 mu g/min and 101.15 mu g/min, respectively. For crematoriums, the maximum and minimum value of same was 252.3 mu g/min and 194.31 mu g/min, respectively, for an exposure period of 10 min.
引用
收藏
页码:38374 / 38384
页数:11
相关论文
共 60 条
[1]  
Arnold D, 2016, NTM-J HIST SCI TECHN, V24, P393, DOI 10.1007/s00048-017-0158-7
[2]  
BAILEY MR, 1994, RADIAT PROT DOSIM, V53, P107
[3]  
Bhadauria V, 2020, THESIS HARCOURT BUTL
[4]  
Bhadauriya V, 2020, DEV EMERGING EC CRSI, P159
[5]   Health exposure of users of indoor sports centers related to the physico-chemical properties of particulate matter [J].
Bralewska, Karolina ;
Rogula-Kozlowska, Wioletta .
BUILDING AND ENVIRONMENT, 2020, 180
[6]   Aerosol mixing state matters for particles deposition in human respiratory system [J].
Ching, Joseph ;
Kajino, Mizuo .
SCIENTIFIC REPORTS, 2018, 8
[7]   Cause-specific premature death from ambient PM2.5 exposure in India: Estimate adjusted for baseline mortality [J].
Chowdhury, Sourangsu ;
Dey, Sagnik .
ENVIRONMENT INTERNATIONAL, 2016, 91 :283-290
[8]  
CPCB, 2013, NAT AMB AIR QUAL SER, VI
[9]   Physiochemical characteristics of aerosol particles collected from the Jokhang Temple indoors and the implication to human exposure [J].
Cui, Lulu ;
Duo, Bu ;
Zhang, Fei ;
Li, Chunlin ;
Fu, Hongbo ;
Chen, Jianmin .
ENVIRONMENTAL POLLUTION, 2018, 236 :992-1003
[10]   Non-carcinogenic and Carcinogenic Risk Assessment of Trace Elements of PM2.5 During Winter and Pre-monsoon Seasons in Delhi: A Case Study [J].
Das, Ananya ;
Singh, Gaurav ;
Habib, Gazala ;
Kumar, Arun .
EXPOSURE AND HEALTH, 2020, 12 (01) :63-77