Face and Content Validity of Transurethral Resection of Prostate on Uro Trainer: Is the Simulation Training Useful?

被引:7
作者
Mishra, Shashikant [1 ]
Kurien, Abraham [1 ]
Ganpule, Arvind [1 ]
Veeramani, Muthu [1 ]
Sabnis, R. B. [1 ]
Desai, Mahesh [1 ]
机构
[1] Muljibhai Patel Urol Hosp, Dept Urol, Nadiad 387001, Gujarat, India
关键词
LOWER URINARY-TRACT; VIRTUAL-REALITY; SURGICAL SIMULATION; PERSPECTIVE; VALIDATION;
D O I
10.1089/end.2009.0612
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Background: Uro Trainer (UT; Karl Storz GmbH, Tuttlingen, Germany), a virtual reality simulator for transurethral resection of prostate (TURP), has been infrequently validated. To ascertain the utility of such a trainer, we performed a basic face and content validity study. Materials and Methods: Ten experts and nine novices (done more than 50 and less than 3 TURPs, respectively) performed a TURP on UT and rated simulator usefulness (seven items), realism (five items), and overall score (one item) on a Likert's 10-point scale. Scores of <6.0, 6.0 to 8.0, and >8.0 on the Likert scale 1 to 10 were considered not, slightly, and highly acceptable, respectively. Results: Novices rated UT as more helpful than experts in the following aspects of face and content validity: usefulness general (p = 0.0001, statistically significant), hand-eye coordination (p = 0.04, statistically significant), material knowledge and skills (p = 0.02, statistically significant), spatial skills (p = 0.003, statistically significant), cystoscopy (p = 0.002, statistically significant), TURP (0.002, statistically significant), visual aspects (p = 0.003, statistically significant), and overall score (p = 0.007, statistically significant). One item of usefulness (coagulation) and three items of realism (tissue feel, depth feel, and capsule identification) failed to impress both novice and experts. UT usefulness domain was highly acceptable for 77.7% and slightly acceptable for 100% of the novices and experts, respectively. The general realism domain was highly and slightly acceptable for 33.3% and 66.6% of the novices while slightly acceptable for 100% of the experts. Conclusion: Novice group found UT more useful than the experts group. Further modification is advisable to increase the realism of the UT.
引用
收藏
页码:1839 / 1843
页数:5
相关论文
共 34 条
  • [31] Face, content, and construct validity of the virtual immersive operating room simulator for training laparoscopic procedures
    Perez-Escamirosa, Fernando
    Areli Garcia-Cabra, Damaris
    Ricardo Ortiz-Hernandez, Jose
    Montoya-Alvarez, Salvador
    Alfredo Ruiz-Vereo, Eduardo
    Manuel Ordorica-Flores, Ricardo
    Minor-Martinez, Arturo
    Tapia-Jurado, Jesus
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2023, 37 (04): : 2885 - 2896
  • [32] Face, content, and construct validity of the EndoViS training system for objective assessment of psychomotor skills of laparoscopic surgeons
    Fernando Pérez Escamirosa
    Ricardo Manuel Ordorica Flores
    Ignacio Oropesa García
    Cristian Rubén Zalles Vidal
    Arturo Minor Martínez
    Surgical Endoscopy, 2015, 29 : 3392 - 3403
  • [33] Face, content, construct and concurrent validity of dry laboratory exercises for robotic training using a global assessment tool
    Ramos, Patrick
    Montez, Jeremy
    Tripp, Adrian
    Ng, Casey K.
    Gill, Inderbir S.
    Hung, Andrew J.
    BJU INTERNATIONAL, 2014, 113 (05) : 836 - 842
  • [34] Face, content, and construct validity of four, inanimate training exercises using the da Vinci A® Si surgical system configured with Single-Site ™ instrumentation
    Jarc, Anthony M.
    Curet, Myriam
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2015, 29 (08): : 2298 - 2304