Elastic biodegradable poly(glycolide-co-caprolactone) scaffold for tissue engineering

被引:144
作者
Lee, SH
Kim, BS
Kim, SH
Choi, SW
Jeong, SI
Kwon, IK
Kang, SW
Nikolovski, J
Mooney, DJ
Han, YK
Kim, YH
机构
[1] Korea Inst Sci & Technol, Biomat Res Ctr, Seoul 130650, South Korea
[2] Hanyang Univ, Dept Chem Engn, Seoul 133791, South Korea
[3] Hanyang Univ, Dept Chem, Seoul 133791, South Korea
[4] Korea & Ctr Adv Funct Polymers, KAIST, Taejon 305701, South Korea
[5] Univ Michigan, Dept Chem Engn, Ann Arbor, MI 48109 USA
[6] Univ Michigan, Dept Biomed Engn, Ann Arbor, MI 48109 USA
[7] Univ Michigan, Dept Biol Mat Sci, Ann Arbor, MI 48109 USA
关键词
poly(glycolide-co-caprolactone); elastic biodegradable scaffold; smooth muscle cell; tissue engineering;
D O I
10.1002/jbm.a.10497
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Cyclic mechanical strain has been demonstrated to enhance the development and function of engineered smooth muscle (SM) tissues, and it would be necessary for the development of the elastic scaffolds if one wishes to engineer SM tissues under cyclic mechanical loading. This study reports on the development of an elastic scaffold fabricated from a biodegradable polymer. Biodegradable poly(glycolide-co-caprolactone) (PGCL) copolymer was synthesized from glycolide and is an element of-caprolactone in the presence of stannous octoate as catalyst. The copolymer was characterized by H-1-NMR, gel permeation chromatography and differential scanning calorimetry. Scaffolds for tissue engineering applications were fabricated from PGCL copolymer using the solvent-casting and particle-leaching technique. The PGCL scaffolds produced in this fashion had open pore structures (average pore size = 250 mum) without the usual nonporous skin layer on external surfaces. Mechanical testing revealed that PGCL scaffolds were far more elastic than poly(lactic-co-glycolic acid) (PLGA) scaffolds fabricated using the same method. Tensile mechanical tests indicated that PGCL scaffolds Could withstand an extension of 250% with-out cracking, which was much higher than withstood by PLGA scaffolds (10-15%). In addition, PGCL scaffolds achieved recoveries exceeding 96% at applied extensions of up to 230%, whereas PLGA scaffolds failed (cracked) at an applied strain of 20%. Dynamic mechanical tests showed that the permanent deformation of the PGCL scaffolds in a dry condition produced was less than 4% of the applied strain, when an elongation of 20% at a frequency of 1 Hz (1 cycle per second) was applied for 6 days. Moreover, PGCL scaffolds in a buffer solution also had permanent deformations less than 5% of the applied strain when an elongation of 10% at a frequency of 1 Hz was applied for 2 days. The usefulness of the PGCL scaffolds was demonstrated by engineering SM tissues in vivo. This study shows that the elastic PGCL scaffolds produced in this study could be used to engineer SM-containing tissues (e.g. blood vessels and bladders) in mechanically dynamic environments. (C) 2003 Wiley Periodicals, Inc.
引用
收藏
页码:29 / 37
页数:9
相关论文
共 26 条
[1]  
[Anonymous], 2013, Biomechanics: Motion, Flow, Stress, and Growth
[2]   EFFECT OF PHYSICAL FORCES ON BLADDER SMOOTH-MUSCLE AND UROTHELIUM [J].
BASKIN, L ;
HOWARD, PS ;
MACARAK, E .
JOURNAL OF UROLOGY, 1993, 150 (02) :601-607
[3]   MONOCRYL(R) SUTURE, A NEW ULTRA-PLIABLE ABSORBABLE MONOFILAMENT SUTURE [J].
BEZWADA, RS ;
JAMIOLKOWSKI, DD ;
LEE, IY ;
AGARWAL, V ;
PERSIVALE, J ;
TRENKABENTHIN, S ;
ERNETA, M ;
SURYADEVARA, J ;
YANG, A ;
LIU, S .
BIOMATERIALS, 1995, 16 (15) :1141-1148
[4]   STRETCH AFFECTS PHENOTYPE AND PROLIFERATION OF VASCULAR SMOOTH-MUSCLE CELLS [J].
BIRUKOV, KG ;
SHIRINSKY, VP ;
STEPANOVA, OV ;
TKACHUK, VA ;
HAHN, AWA ;
RESINK, TJ ;
SMIRNOV, VN .
MOLECULAR AND CELLULAR BIOCHEMISTRY, 1995, 144 (02) :131-139
[5]  
CAO Y, 1994, TRANSPLANT P, V26, P3390
[6]   Mechanical load induces sarcoplasmic wounding and FGF release in differentiated human skeletal muscle cultures [J].
Clarke, MSF ;
Feeback, DL .
FASEB JOURNAL, 1996, 10 (04) :502-509
[7]   Cross-linking of dermal sheep collagen using a water-soluble carbodiimide [J].
Damink, LHHO ;
Dijkstra, PJ ;
vanLuyn, MJA ;
vanWachem, PB ;
Nieuwenhuis, P ;
Feijen, J .
BIOMATERIALS, 1996, 17 (08) :765-773
[8]  
Harris LD, 1998, J BIOMED MATER RES, V42, P396, DOI 10.1002/(SICI)1097-4636(19981205)42:3<396::AID-JBM7>3.3.CO
[9]  
2-P
[10]   BIOCHEMICAL-CHANGES AND CYTOTOXICITY ASSOCIATED WITH THE DEGRADATION OF POLYMERIC GLUTARALDEHYDE DERIVED CROSS-LINKS [J].
HUANGLEE, LLH ;
CHEUNG, DT ;
NIMNI, ME .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1990, 24 (09) :1185-1201