Chemical Modifications of Therapeutic Proteins Induced by Residual Ethylene Oxide

被引:22
作者
Chen, Louise [1 ]
Sloey, Christopher [1 ]
Zhang, Zhongqi [1 ]
Bondarenko, Pavel V. [1 ]
Kim, Hyojin [1 ]
Ren, Da [1 ]
Kanapuram, Sekhar [1 ]
机构
[1] Amgen Inc, Proc & Prod Dev, Thousand Oaks, CA 91320 USA
关键词
drug delivery systems; injectables; protein delivery; chromatography; HPLC; mass spectrometry; proteins; peptides; formulation; analytical biochemistry; MEDICAL DEVICES; METHIONINE RESIDUES; STERILIZATION; OXIDATION;
D O I
10.1002/jps.24257
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
Ethylene oxide (EtO) is widely used in sterilization of drug product primary containers and medical devices. The impact of residual EtO on protein therapeutics is of significant interest in the biopharmaceutical industry. The potential for EtO to modify individual amino acids in proteins has been previously reported. However, specific identification of EtO adducts in proteins and the effect of residual EtO on the stability of therapeutic proteins has not been reported to date. This paper describes studies of residual EtO with two therapeutic proteins, a PEGylated form of the recombinant human granulocyte colony-stimulating factor (Peg-GCSF) and recombinant human erythropoietin (EPO) formulated with human serum albumin (HSA). Peg-GCSF was filled in an EtO sterilized delivery device and incubated at accelerated stress conditions. Glu-C peptide mapping and LC-MS analyses revealed residual EtO reacted with Peg-GCSF and resulted in EtO modifications at two methionine residues (Met-127 and Met-138). In addition, tryptic peptide mapping and LC-MS analyses revealed residual EtO in plastic vials reacted with HSA in EPO formulation at Met-328 and Cys-34. This paper details the work conducted to understand the effects of residual EtO on the chemical stability of protein therapeutics. (c) 2014 Wiley Periodicals, Inc. and the American Pharmacists Association J Pharm Sci 104:731-739, 2015
引用
收藏
页码:731 / 739
页数:9
相关论文
共 16 条
[1]   Direct observation of covalent adducts with Cys34 of human serum albumin using mass spectrometry [J].
Beck, JL ;
Ambahera, S ;
Yong, SR ;
Sheil, MM ;
de Jersey, J ;
Ralph, SF .
ANALYTICAL BIOCHEMISTRY, 2004, 325 (02) :326-336
[2]  
Buben L, 1999, CENT EUR J PUBL HEAL, V7, P197
[3]   Molecular dynamics simulations and oxidation rates of methionine residues of granulocyte colony-stimulating factor at different pH values [J].
Chu, JW ;
Yin, J ;
Wang, DIC ;
Trout, BL .
BIOCHEMISTRY, 2004, 43 (04) :1019-1029
[4]   Sterilization of Medical Devices by Ethylene Oxide, Determination of the Dissipation of Residues, and Use of Green Fluorescent Protein as an Indicator of Process Control [J].
Dias, Fabio N. ;
Ishii, Marina ;
Nogaroto, Sergio L. ;
Piccini, Bruno ;
Penna, Thereza C. V. .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2009, 91B (02) :626-630
[5]   EFFECT OF METHODS OF STERILIZATION ON NUTRITIVE-VALUE OF PROTEIN IN A COMMERICAL RAT DIET [J].
FORD, DJ .
BRITISH JOURNAL OF NUTRITION, 1976, 35 (02) :267-276
[6]   IGE AGAINST ETHYLENE OXIDE-ALTERED HUMAN-SERUM ALBUMIN (ETO-HSA) AS AN ETIOLOGIC AGENT IN ALLERGIC REACTIONS OF HEMODIALYSIS-PATIENTS [J].
GRAMMER, LC ;
PATTERSON, R .
ARTIFICIAL ORGANS, 1987, 11 (02) :97-99
[7]  
Jiang XY, 1996, J MASS SPECTROM, V31, P1309, DOI 10.1002/(SICI)1096-9888(199611)31:11<1309::AID-JMS423>3.0.CO
[8]  
2-R
[9]   STERILIZATION BY ETHYLENE OXIDE [J].
KELSEY, JC .
JOURNAL OF CLINICAL PATHOLOGY, 1961, 14 (01) :59-&
[10]   Residual ethylene oxide in medical devices and device material [J].
Lucas, AD ;
Merritt, K ;
Hitchins, VM ;
Woods, TO ;
McNamee, SG ;
Lyle, DB ;
Brown, SA .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2003, 66B (02) :548-552