One-year results of the INSPIRE trial with the novel MGuard stent: Serial analysis with QCA and IVUS

被引:9
作者
Costa, J. Ribamar, Jr. [1 ]
Abizaid, Alexandre [1 ]
Feres, Fausto [1 ]
Costa, Ricardo [1 ]
Staico, Rodolfo [1 ]
Siqueira, Dimytri [1 ]
Centemero, Marinella [1 ]
Tanajura, Luiz Fernando [1 ]
Sousa, Amanda [1 ]
Sousa, J. Eduardo [1 ]
机构
[1] Inst Dante Pazzanese Cardiol, Dept Invas Cardiol, Sao Paulo, Brazil
关键词
ACS; acute coronary syndrome; NRFL; no reflow; QCA; quantitative coronary angiography; GRFT; bypass grafts coronary; IVUS; intravascular ultrasound; SAPHENOUS-VEIN GRAFTS; BARE-METAL STENT; ELEVATION MYOCARDIAL-INFARCTION; SIROLIMUS-ELUTING STENT; INTRAVASCULAR ULTRASOUND; IMPLANTATION; LESIONS; EMBOLIZATION; EXPERIENCE; NET;
D O I
10.1002/ccd.22980
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The newly developed balloon-expandable Mguard stent system, a combination of an ultra-thin polymer mesh sleeve attached to the external surface of a BMS, was conceived to provide embolic protection during PCI of SVG and thrombus-containig lesions. Although the acute results (<30 days) have pointed to the efficacy of this novel device, few is known about its long-term performance. Methods: The present article address the 1-year clinical results of a cohort of 30 patients enrolled in the INSPIRE trial. Inclusion critiria was de novo lesions in SVG or native vessels with angiographic evidence of instability with potential to provoke flow disturbances and/or distal embolization. The primary endpoint (incidence of MACE-composite of cardiac death, nonfatal MI, and TLR) up to 30 days of the procedure has already been published. Secondary endpoints here presented included in-stent late lumen loss (QCA), % of stent obstruction (IVUS) at 6 months and combined MACE at 1 year. QCA and IVUS were performed by independent corelabs. Results: Mean population age was 63 years with 38% of diabetics. Overall, 55% presented with ACS and 57% of lesions were located in SVG. Most lesions had complex morphology including the presence of thrombus (26%) and ulceration (20%). Distal/proximal protection devices were not used. Preprocedural QCA data showed lesion length and reference vessel diameter of 12.0 +/- 4.5 mm and 3.0 +/- 0.5 mm. The MGuard stent was successfully delivered in all cases and final TIMI-3 was achieved in 100% with no MACE up to 30 days. At 6 months, in-stent late loss and % of stent obstruction were 1.0 +/- 0.4 mm and 28.5 > 15.6%. Up to 1 year there was no case of cardiac death, two MI (one Q-wave and one non-Q-wave) and six cases of ischemia-driven TLR. Of note, there was no case of definite/probable stent thorombosis. Conclusions: In this series of patients treated with MGuard stent, the novel device showed no midterm efficacy and safety concerns. (c) 2011 Wiley Periodicals, Inc.
引用
收藏
页码:1095 / 1100
页数:6
相关论文
共 13 条
[1]   Intravascular ultrasound comparison of Sirolimus-eluting stent versus bare metal stent implantation in diseased saphenous vein grafts (from the RRISC [Reduction of restenosis in saphenous vein grafts with cypher sirolimus-eluting stent] trial) [J].
Agostoni, Pierfrancesco ;
Vermeersch, Paul ;
Semeraro, Oscar ;
Verheye, Stefan ;
Van Langenhove, Glenn ;
Van den Heuvel, Paul ;
Convens, Carl ;
Van den Branden, Frank ;
Bruining, Nico .
AMERICAN JOURNAL OF CARDIOLOGY, 2007, 100 (01) :52-58
[2]   A Randomized Controlled Trial of a Paclitaxel-Eluting Stent Versus a Similar Bare-Metal Stent in Saphenous Vein Graft Lesions The SOS (Stenting Of Saphenous Vein Grafts) Trial [J].
Brilakis, Emmanouil S. ;
Lichtenwalter, Christopher ;
de Lemos, James A. ;
Roesle, Michele ;
Obel, Owen ;
Haagen, Donald ;
Saeed, Bilal ;
Gadiparthi, Chiranjeevi ;
Bissett, Joseph K. ;
Sachdeva, Rajesh ;
Voudris, Vassilios V. ;
Karyofillis, Panagiotis ;
Kar, Biswajit ;
Rossen, James ;
Fasseas, Panayotis ;
Berger, Peter ;
Banerjee, Subhash .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (11) :919-928
[3]   Mesh covered stent in ST-segment elevation myocardial infarction [J].
Dudek, Dariusz ;
Dziewierz, Artur ;
Rzeszutko, Lukasz ;
Legutko, Jacek ;
Dobrowolski, Wojciech ;
Rakowski, Tomasz ;
Bartus, Stanislaw ;
Dragan, Jacek ;
Klecha, Artur ;
Lansky, Alexandra-J ;
Siudak, Zhigniew ;
Zmudka, Krzysztof .
EUROINTERVENTION, 2010, 6 (05) :582-589
[4]   The coronary no-reflow phenomenon: a review of mechanisms and therapies [J].
Eeckhout, E ;
Kern, MJ .
EUROPEAN HEART JOURNAL, 2001, 22 (09) :729-739
[5]   Are we making progress with percutaneous saphenous vein graft treatment? A comparison of 1990 to 1994 and 1995 to 1998 results [J].
Hong, MK ;
Mehran, R ;
Dangas, G ;
Mintz, GS ;
Lansky, A ;
Kent, KM ;
Pichard, AD ;
Satler, LF ;
Stone, GW ;
Leon, MB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 38 (01) :150-154
[6]  
Kaluski E, 2008, J INVASIVE CARDIOL, V20, P511
[7]   Preliminary Results of the INSPIRE Trial With the Novel MGuard™ Stent System Containing a Protection Net to Prevent Distal Embolization [J].
Maia, Felipe ;
Ribamar Costa, J., Jr. ;
Abizaid, Alexandre ;
Feres, Fausto ;
Costa, Ricardo ;
Staico, Rodolfo ;
Siqueira, Dimytri ;
Esteves, Vinicius ;
Sousa, Amanda ;
Eduardo Sousa, J. .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2010, 76 (01) :86-92
[8]   Multicentre Experience With MGuard™ Net Protective Stent in ST-Elevation Myocardial Infarction: Safety, Feasibility, and Impact on Myocardial Reperfusion [J].
Piscione, Federico ;
Danzi, Gian Battista ;
Cassese, Salvatore ;
Esposito, Giovanni ;
Cirillo, Plinio ;
Galasso, Gennaro ;
Rapacciuolo, Antonio ;
Leosco, Dario ;
Briguori, Carlo ;
Varbella, Ferdinando ;
Tuccillo, Bernardino ;
Chiariello, Massimo .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2010, 75 (05) :715-721
[9]   Comparison of Plaque Sealing With Paclitaxel-Eluting Stents Versus Medical Therapy for the Treatment of Moderate Nonsignificant Saphenous Vein Graft Lesions The Moderate VEin Graft LEsion Stenting With the Taxus Stent and Intravascular Ultrasound (VELETI) Pilot Trial [J].
Rodes-Cabau, Josep ;
Bertrand, Olivier F. ;
Larose, Eric ;
Dery, Jean-Pierre ;
Rinfret, Stephane ;
Bagur, Rodrigo ;
Proulx, Guy ;
Nguyen, Can M. ;
Cote, Melanie ;
Landcop, Marie-Claude ;
Boudreault, Jean-Rock ;
Rouleau, Jacques ;
Roy, Louis ;
Gleeton, Onil ;
Barbeau, Gerald ;
Noel, Bernard ;
Courtis, Javier ;
Dagenais, Gilles R. ;
Despres, Jean-Pierre ;
DeLarochelliere, Robert .
CIRCULATION, 2009, 120 (20) :1978-1986
[10]   Recognition of the importance of embolization in atherosclerotic vascular disease [J].
Topol, EJ ;
Yadav, JS .
CIRCULATION, 2000, 101 (05) :570-580