Management of malignant biliary obstruction: Technical and clinical results using an expanded polytetrafluoroethylene fluorinated ethylene propylene (ePTFE/FEP)-covered metallic stent after 6-year experience

被引:33
作者
Fanelli, Fabrizio [1 ]
Orgera, Gianluigi [1 ]
Bezzi, Mario [1 ]
Rossi, Plinio [1 ]
Allegritti, Massimiliano [1 ]
Passariello, Roberto [1 ]
机构
[1] Univ Roma La Sapienza, Dept Radiol Sci, I-00161 Rome, Italy
关键词
biliary; stricture; malignant; stent; covered;
D O I
10.1007/s00330-008-0852-x
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To evaluate the efficacy and safety of an expanded polytetrafluoroethylene-fluorinated ethylene-propylene (ePTFE/FEP)-covered metallic stent in the management of malignant biliary obstruction. Eighty consecutive patients with malignant common bile duct strictures were treated by placement of 83 covered metallic stents. The stent-graft consists of an inner ePTFE/FEP lining and an outer supporting structure of nitinol wire. Clinical evaluation, assessment of serum bilirubin and liver enzyme levels were analyzed before biliary drainage, before stent-graft placement and during the follow-up period at 1, 3, 6, 9 and 12 months. Technical success was obtained in all cases. After a mean follow-up of 6.9 +/- 4.63 months, the 30-day mortality rate was 14.2%. Survival rates were 40% and 20.2% at 6 and 12 months, respectively. Stent-graft patency rates were 95.5%, 92.6% and 85.7% at 3, 6 and 12 months, respectively. Complications occurred in five patients (6.4%); among these, acute cholecystitis was observed in three patients (3.8%). A stent-graft occlusion rate of 9% was observed. The percentage of patients undergoing lifetime palliation (91%) and the midterm patency rate suggest that placement of this ePTFE/FEP-covered stent-graft is safe and highly effective in achieving biliary drainage in patients with malignant strictures of the common bile duct.
引用
收藏
页码:911 / 919
页数:9
相关论文
共 20 条
[1]   New ePTFE/FEP-covered stent in the palliative treatment of malignant biliary obstruction [J].
Bezzi, M ;
Zolovkins, A ;
Cantisani, V ;
Salvatori, FM ;
Rossi, M ;
Fanelli, F ;
Rossi, P .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2002, 13 (06) :581-589
[2]  
Dick B W, 1990, J Vasc Interv Radiol, V1, P97, DOI 10.1016/S1051-0443(90)72511-0
[3]   SELF-EXPANDABLE STAINLESS-STEEL BRAIDED ENDOPROSTHESIS FOR BILIARY STRICTURES [J].
GILLAMS, A ;
DICK, R ;
DOOLEY, JS ;
WALLSTEN, H ;
ELDIN, A .
RADIOLOGY, 1990, 174 (01) :137-140
[4]   MALIGNANT BILIARY OBSTRUCTION - TREATMENT WITH EXPANDABLE METALLIC STENTS - FOLLOW-UP OF 50 CONSECUTIVE PATIENTS [J].
GORDON, RL ;
RING, EJ ;
LABERGE, JM ;
DOHERTY, MM .
RADIOLOGY, 1992, 182 (03) :697-701
[5]   ePTFE/FEP-covered metallic stents for palliation of malignant biliary disease: Can tumor ingrowth be prevented? [J].
Hatzidakis, Adam ;
Krokidis, Miltiadis ;
Kalbakis, Kostantinos ;
Romanos, Jiannis ;
Petrakis, Ioannis ;
Gourtsoyiannis, Nicholas .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2007, 30 (05) :950-958
[6]   Treatment of malignant biliary obstruction with polyurethane-covered wallstents [J].
Hausegger, KA ;
Thurnher, S ;
Bodendörfer, G ;
Zollikofer, CL ;
Uggowitzer, M ;
Kugler, C ;
Lammer, J .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (02) :403-408
[7]   NONPARAMETRIC-ESTIMATION FROM INCOMPLETE OBSERVATIONS [J].
KAPLAN, EL ;
MEIER, P .
JOURNAL OF THE AMERICAN STATISTICAL ASSOCIATION, 1958, 53 (282) :457-481
[8]   Long-term follow-up in patients with malignant biliary obstruction after percutaneous placement of uncovered wallstent endoprostheses [J].
Kaskarelis, IS ;
Papadaki, MG ;
Papageorgiou, GN ;
Limniati, MD ;
Malliaraki, NE ;
Piperopoulos, PN .
ACTA RADIOLOGICA, 1999, 40 (05) :528-533
[9]   Intentional retrieval of Viabil stent-grafts from the biliary system [J].
Kuo, MD ;
LoPresti, DC ;
Gover, DD ;
Hall, LD ;
Ferrara, SL .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2006, 17 (02) :389-397
[10]   Common bile duct obstruction due to malignancy: Treatment with plastic versus metal stents [J].
Lammer, J ;
Hausegger, KA ;
Fluckiger, F ;
Winkelbauer, FW ;
Wilding, R ;
Klein, GE ;
Thurnher, SA ;
Havelec, L .
RADIOLOGY, 1996, 201 (01) :167-172