In-Line Monitoring of Particle Size during Emulsion Polymerization under Different Operational Conditions using NIR Spectroscopy

被引:20
作者
Chicoma, Dennis L. [1 ]
Sayer, Claudia [2 ]
Giudici, Reinaldo [1 ]
机构
[1] Univ Sao Paulo, Dept Engn Quim, Escola Politecn, BR-05424970 Sao Paulo, Brazil
[2] Univ Fed Santa Catarina, Dept Engn Quim & Alimentos, CTC, BR-88040970 Florianopolis, SC, Brazil
基金
巴西圣保罗研究基金会;
关键词
emulsion polymerization; light scattering; NIR spectroscopy; online monitoring; particle size; VINYL-ACETATE; COPOLYMERIZATION REACTIONS; INFRARED-SPECTROSCOPY; RAMAN-SPECTROSCOPY; REACTORS; DESIGN; POWDER; MODEL;
D O I
10.1002/mren.201000049
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
In the present work, the sensitivity of NIR spectroscopy toward the evolution of particle size was studied during emulsion homopolymerization of styrene (Sty) and emulsion copolymerization of vinyl acetate-butyl acrylate conducted in a semibatch stirred tank and a tubular pulsed sieve plate reactor, respectively. All NIR spectra were collected online with a transflectance probe immersed into the reaction medium. The spectral range used for the NIR monitoring was from 9 500 to 13 000 cm(-1), where the absorbance of the chemical components present is minimal and the changes in the NIR spectrum can be ascribed to the effects of light scattering by the polymer particles. Off-line measurements of the average diameter of the polymer particles by DLS were used as reference values for the development of the multi-variate NIR calibration models based on partial least squares. Results indicated that, in the spectral range studied, it is possible to monitor the evolution of the average size of the polymer particles during emulsion polymerization reactions. The inclusion of an additional spectral range, from 5 701 to 6 447 cm(-1), containing information on absorbances ("chemical information") in the calibration models was also evaluated.
引用
收藏
页码:150 / 162
页数:13
相关论文
共 40 条
[1]  
Araújo PHH, 2001, MACROMOL THEOR SIMUL, V10, P769, DOI 10.1002/1521-3919(20011001)10:8<769::AID-MATS769>3.0.CO
[2]  
2-Z
[3]   Comparison of vinyl acetate-butyl acrylate emulsion copolymerizations conducted in a continuous pulsed sieve plate column reactor and in a batch stirred tank reactor [J].
Carvalho, Antonio C. S. M. ;
Chicoma, Dennis ;
Sayer, Claudia ;
Giudici, Reinaldo .
MACROMOLECULAR SYMPOSIA, 2006, 243 :147-158
[4]   Development of a Continuous Emulsion Copolymerization Process in a Tubular Reactor [J].
Carvalho, Antonio C. S. M. ;
Chicoma, Dennis L. ;
Sayer, Claudia ;
Giudici, Reinaldo .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2010, 49 (21) :10262-10273
[5]   In Line Monitoring of VAc-BuA Emulsion Polymerization Reaction in a Continuous Pulsed Sieve Plate Reactor using NIR Spectroscopy [J].
Chicoma, Dennis ;
Carranza, Veronica ;
Sayer, Claudia ;
Giudici, Reinaldo .
MACROMOLECULAR SYMPOSIA, 2010, 289 :140-148
[6]   Monitoring of high solids content starved-semi-batch emulsion copolymerization reactions by Fourier transform Raman spectroscopy [J].
Elizalde, O ;
Asua, JM ;
Leiza, JR .
APPLIED SPECTROSCOPY, 2005, 59 (10) :1270-1279
[7]   Monitoring emulsion polymerization reactors: Calorimetry versus Raman spectroscopy [J].
Elizalde, O ;
Azpeitia, M ;
Reis, MM ;
Asua, JM ;
Leiza, JR .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2005, 44 (18) :7200-7207
[8]   Monitoring and control of styrene solution polymerization using NIR spectroscopy [J].
Fontoura, JMR ;
Santos, AF ;
Silva, FM ;
Lenzi, MK ;
Lima, EL ;
Pinto, JC .
JOURNAL OF APPLIED POLYMER SCIENCE, 2003, 90 (05) :1273-1289
[9]   COMPOSITION AND PARTICLE DIAMETER FOR STYRENE-METHYL METHACRYLATE COPOLYMER LATEX USING UV AND NIR SPECTROSCOPY [J].
GOSSEN, PD ;
MACGREGOR, JF ;
PELTON, RH .
APPLIED SPECTROSCOPY, 1993, 47 (11) :1852-1870
[10]   Formation, growth, and inhibition of calcium naphthenate particles in oil/water systems as monitored by means of near infrared spectroscopy [J].
Hanneseth, AMD ;
Brandal, O ;
Sjöblom, J .
JOURNAL OF DISPERSION SCIENCE AND TECHNOLOGY, 2006, 27 (02) :185-192