Comparison of Marginal Fit and Internal Adaptation of Copings Fabricated with Polyetheretherketone and Zirconia - An In vitro Study

被引:7
作者
Amalorpavam, V [1 ]
Sreelal, T. [2 ]
Chandramohan, Giri [2 ]
Jithin, G. N. [3 ]
Ponjayanthi [4 ]
Kamalashankar [5 ]
机构
[1] Rajas Dent Coll & Hosp, Dept Prosthodont, Tirunelveli 627105, Tamil Nadu, India
[2] Sree Mookambika Inst Dent Sci, Dept Prosthodont, Kulasekaram, Kanya Kumari, India
[3] Smile Care Multispecial Dent Clin, Trivandrum, Kerala, India
[4] Vivekanadha Dent Coll Women, Dept Prosthodont, Tiruchengode, India
[5] Chettinad Dent Coll, Dept Prosthodont, Chennai, Tamil Nadu, India
来源
JOURNAL OF PHARMACY AND BIOALLIED SCIENCES | 2021年 / 13卷 / 06期
关键词
Copings; internal adaptation; marginal fit; polyetheretherketone; zirconia; CERAMIC CROWNS;
D O I
10.4103/jpbs.jpbs_328_21
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Context: Purpose: The aim of this in vitro study was to evaluate and compare the Marginal fit and Internal adaptation of copings fabricated with polyetheretherketone (PEEK) and Zirconia luted with resin cements. Materials and Methods: Maxillary first premolar was prepared to receive all ceramic restoration. It was duplicated using addition silicon impression material for fabricating Cobalt-Chromium metal die, which is used as a master die. Using the master die, 30 heat cure acrylic samples were fabricated for the heat cure acrylic tooth models on which 15 PEEK and 15 zirconia copings were made. Self-adhesive resin cement is used for luting and 30 copings were luted. After 24 h, luted copings were having a disc of thickness 0.01 mm cutting at high speed using a Tooth cutting lathe for all the 30 samples. Field Scanning Electron Microscopic study analysis for evaluating marginal fit and internal adaptation of two groups were observed. The values were then analyzed using one-way ANOVA (post hoc) followed by Dunnet t-test. Results: Among those two groups, PEEK copings group materials showed the lowest mean value of (30.3 +/- 5.1) for marginal gap, (29.1 +/- 5.8) for internal gap whereas the zirconia copings group showed a mean value of (50.26 +/- 16.02) and (32.8 +/- 5.2) respectively. Conclusion: Among these two groups, comparatively less marginal fit and internal adaptation is seen in zirconia copings when compared to the PEEK copings. While the marginal fit and internal adaptation of both PEEK and zirconia copings were in the acceptable clinical range.
引用
收藏
页码:S1199 / S1205
页数:7
相关论文
共 19 条
[1]   Comparison of marginal and internal adaptation of copings fabricated from three different fabrication techniques: An in vitro study [J].
Arora, Aman ;
Yadav, Avneet ;
Upadhyaya, Viram ;
Jain, Prachi ;
Verma, Mrinalini .
JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2018, 18 (02) :102-107
[2]  
Assif D, 1987, Quintessence Int, V18, P765
[3]   Three-dimensional analysis of marginal and internal fit of copings fabricated with polyetherketoneketone (PEKK) and zirconia [J].
Bae, So-Yeon ;
Park, Jin-Young ;
Jeong, Il-Do ;
Kim, Hae-Young ;
Kim, Ji-Hwan ;
Kim, Woong-Chul .
JOURNAL OF PROSTHODONTIC RESEARCH, 2017, 61 (02) :106-112
[4]   EVALUATION OF THE MARGINAL FIT OF A ZIRCONIA CERAMIC COMPUTER-AIDED MACHINED (CAM) CROWN SYSTEM [J].
Baig, Mirza Rustum ;
Tan, Keson Beng-Choon ;
Nicholls, Jack I. .
JOURNAL OF PROSTHETIC DENTISTRY, 2010, 104 (04) :216-227
[5]   Digital dentistry: an overview of recent developments for CAD/CAM generated restorations [J].
Beuer, F. ;
Schweiger, J. ;
Edelhoff, D. .
BRITISH DENTAL JOURNAL, 2008, 204 (09) :505-511
[6]   Marginal and internal fit of CAD-CAM-fabricated composite resin and ceramic crowns scanned by 2 intraoral cameras [J].
de Paula Silveira, Alessandra C. ;
Chaves, Sacha B. ;
Hilgert, Leandro A. ;
Ribeiro, Ana Paula D. .
JOURNAL OF PROSTHETIC DENTISTRY, 2017, 117 (03) :386-392
[7]  
Habib SR, 2017, ACTA STOMATOL CROAT, V51, P179, DOI 10.15644/asc51/3/1
[8]   Marginal, Internal Fit and Microleakage of Zirconia Infrastructures: An In-Vitro Study [J].
Korkut, L. ;
Cotert, H. S. ;
Kurtulmus, H. .
OPERATIVE DENTISTRY, 2011, 36 (01) :72-79
[9]  
Koutayas SO, 2009, INT J ESTHET DENT, V4, P348
[10]   Ceramic dental biomaterials and CAD/CAM technology: State of the art [J].
Li, Raymond Wai Kim ;
Chow, Tak Wah ;
Matinlinna, Jukka Pekka .
JOURNAL OF PROSTHODONTIC RESEARCH, 2014, 58 (04) :208-216