Impact of asymmetrical flow field-flow fractionation on protein aggregates stability

被引:25
作者
Bria, Carmen R. M. [1 ]
Williams, S. Kim Ratanathanawongs [1 ]
机构
[1] Colorado Sch Mines, Dept Chem, Lab Adv Separat Technol, Golden, CO 80401 USA
关键词
Field-Flow fractionation; Protein aggregates stability; Light scattering; Shear stress; Focusing; Sample dilution; SIZE-EXCLUSION CHROMATOGRAPHY; MONOCLONAL-ANTIBODY; SYNTHETIC-POLYMERS; HIGH-PERFORMANCE; CHANNEL; QUANTITATION; FORMULATION; SEPARATION; RETENTION; WATER;
D O I
10.1016/j.chroma.2016.08.037
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The impact of asymmetrical flow field-flow fractionation (AF4) on protein aggregate species is investigated with the aid of multiangle light scattering (MALS) and dynamic light scattering (DLS). The experimental parameters probed in this study include aggregate stability in different carrier liquids, shear stress (related to sample injection), sample concentration (during AF4 focusing), and sample dilution (during separation). Two anti-streptavidin (anti-SA) IgG1 samples composed of low and high molar mass (M) aggregates are subjected to different AF4 conditions. Aggregates suspended and separated in phosphate buffer are observed to dissociate almost entirely to monomer. However, aggregates in citric acid buffer are partially stable with dissociation to 25% and 5% monomer for the low and high M samples, respectively. These results demonstrate that different carrier liquids change the aggregate stability and low M aggregates can behave differently than their larger counterparts. Increasing the duration of the AF4 focusing step showed no significant changes in the percent monomer, percent aggregates, or the average Ms in either sample. Syringe-induced shear related to sample injection resulted in an increase in hydrodynamic diameter (d(h)) as measured by batch mode DLS. Finally, calculations showed that dilution during AF4 separation is significantly lower than in size exclusion chromatography with dilution occurring mainly at the AF4 channel outlet and not during the separation. This has important ramifications when analyzing aggregates that rapidly dissociate (<similar to 2 s) upon dilution as the size calculated by AF4 theory may be more accurate than that measured by online DLS. Experimentally, the d(h)s determined by online DLS generally agreed with AF4 theory except for the more well retained larger aggregates for which DLS showed smaller sizes. These results highlight the importance of using AF4 retention theory to understand the impacts of dilution on analytes. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:155 / 164
页数:10
相关论文
共 50 条
[21]   Nanoparticle separation with a miniaturized asymmetrical flow field-flow fractionation cartridge [J].
Mueller, David ;
Cattaneo, Stefano ;
Meier, Florian ;
Welz, Roland ;
de Mello, Andrew J. .
FRONTIERS IN CHEMISTRY, 2015, 3
[22]   Asymmetrical flow field-flow fractionation hyphenated to Orbitrap high resolution mass spectrometry for the determination of (functionalised) aqueous fullerene aggregates [J].
Herrero, P. ;
Bauerlein, P. S. ;
Emke, E. ;
Pocurull, E. ;
de Voogt, P. .
JOURNAL OF CHROMATOGRAPHY A, 2014, 1356 :277-282
[23]   Optimization of Asymmetrical Flow Field-flow Fractionation (AF4) [J].
Qureshi, Rashid N. ;
Kok, Wim Th. .
LC GC EUROPE, 2010, 23 (01) :18-+
[24]   Determination of molecular mass distribution of amylopectin using asymmetrical flow field-flow fractionation [J].
Juna, Shazia ;
Williams, Peter A. ;
Davies, Simon .
CARBOHYDRATE POLYMERS, 2011, 83 (03) :1384-1396
[25]   Revision of the calibration experiment in asymmetrical flow field-flow fractionation [J].
Haeusele, Benedikt ;
Gindele, Maxim B. ;
Coelfen, Helmut .
JOURNAL OF CHROMATOGRAPHY A, 2021, 1635
[26]   Analysis of Drug/Plasma Protein Interactions by Means of Asymmetrical Flow Field-Flow Fractionation [J].
Maya Madörin ;
Peter van Hoogevest ;
Rolf Hilfiker ;
Birgit Langwost ;
Gerhard M. Kresbach ;
Markus Ehrat ;
Hans Leuenberger .
Pharmaceutical Research, 1997, 14 :1706-1712
[27]   Characterization of branched ultrahigh molar mass polymers by asymmetrical flow field-flow fractionation and size exclusion chromatography [J].
Otte, T. ;
Pasch, H. ;
Macko, T. ;
Bruell, R. ;
Stadler, F. J. ;
Kaschta, J. ;
Becker, F. ;
Buback, M. .
JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (27) :4257-4267
[28]   Asymmetrical flow field-flow fractionation technique for separation and characterization of biopolymers and bioparticles [J].
Yohannes, G. ;
Jussila, M. ;
Hartonen, K. ;
Riekkola, M. -L. .
JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (27) :4104-4116
[29]   Sample carryover and cleaning procedures for asymmetrical flow field-flow fractionation instrument [J].
Eskelin, K. ;
Oksanen, H. M. ;
Poranen, M. M. .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2021, 1181
[30]   Field-flow fractionation with asymmetrical electroosmotic flow .1. Uncharged particles [J].
Andreev, VP ;
Stepanov, YV ;
Giddings, JC .
JOURNAL OF MICROCOLUMN SEPARATIONS, 1997, 9 (03) :163-168