Modified Variable Step-Size Incremental Conductance MPPT Technique for Photovoltaic Systems

被引:32
作者
Owusu-Nyarko, Isaac [1 ]
Elgenedy, Mohamed A. [2 ]
Abdelsalam, Ibrahim [3 ]
Ahmed, Khaled H. [1 ]
机构
[1] Univ Strathclyde, Dept Elect & Elect Engn, Glasgow G1 1XQ, Lanark, Scotland
[2] Glasgow Caledonian Univ, Sch Comp Engn & Built Environm, Glasgow G4 0BA, Lanark, Scotland
[3] Arab Acad Sci & Technol & Maritime Transport AAST, Dept Elect Engn, Cairo 2033, Egypt
关键词
autonomous scaling factor; photovoltaic (PV); slope angle variation; variable step-size INC; MAXIMUM POWER POINT; HYBRID MPPT; TRACKING TECHNIQUES; PV; ALGORITHM; EFFICIENT;
D O I
10.3390/electronics10192331
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
A highly efficient photovoltaic (PV) system requires a maximum power point tracker to extract peak power from PV modules. The conventional variable step-size incremental conductance (INC) maximum power point tracking (MPPT) technique has two main drawbacks. First, it uses a pre-set scaling factor, which requires manual tuning under different irradiance levels. Second, it adapts the slope of the PV characteristics curve to vary the step-size, which means any small changes in PV module voltage will significantly increase the overall step-size. Subsequently, it deviates the operating point away from the actual reference. In this paper, a new modified variable step-size INC algorithm is proposed to address the aforementioned problems. The proposed algorithm consists of two parts, namely autonomous scaling factor and slope angle variation algorithm. The autonomous scaling factor continuously adjusts the step-size without using a pre-set constant to control the trade-off between convergence speed and tracking precision. The slope angle variation algorithm mitigates the impact of PV voltage change, especially during variable irradiance conditions to improve the MPPT efficiency. The theoretical investigations of the new technique are carried out while its practicability is confirmed by simulation and experimental results.
引用
收藏
页数:18
相关论文
共 34 条
[1]   An Improved Method to Predict the Position of Maximum Power Point During Partial Shading for PV Arrays [J].
Ahmed, Jubaer ;
Salam, Zainal .
IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS, 2015, 11 (06) :1378-1387
[2]  
Ahmed M., 2011, P 8 INT C POW EL ECC
[3]   Effect of Measurement Noise and Bias on Hill-Climbing MPPT Algorithms [J].
Al-Atrash, Hussam ;
Batarseh, Issa ;
Rustom, Khalid .
IEEE TRANSACTIONS ON AEROSPACE AND ELECTRONIC SYSTEMS, 2010, 46 (02) :745-760
[4]   An Efficient Fuzzy-Logic Based Variable-Step Incremental Conductance MPPT Method for Grid-Connected PV Systems [J].
Ali, Mahmoud N. ;
Mahmoud, Karar ;
Lehtonen, Matti ;
Darwish, Mohamed M. F. .
IEEE ACCESS, 2021, 9 :26420-26430
[5]  
Ali R.R., 2012, RENEW SUSTAIN REV, V19, P433
[6]  
Amine AM, 2014, INT CONF MULTIMED, P1563, DOI 10.1109/ICMCS.2014.6911212
[7]   A Time-Based Global Maximum Power Point Tracking Technique for PV System [J].
Aquib, Mohd ;
Jain, Sachin ;
Agarwal, Vivek .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2020, 35 (01) :393-402
[8]   Steady Output and Fast Tracking MPPT (SOFT-MPPT) for P&O and InC Algorithms [J].
Bhattacharyya, Shamik ;
Kumar, Dattu Sampath P. ;
Samanta, Susovon ;
Mishra, Sukumar .
IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2021, 12 (01) :293-302
[9]  
Chin V.J., 2015, P 4 INT C EL POW EN
[10]   Integrated photovoltaic maximum power point tracking converter [J].
Enslin, JHR ;
Wolf, MS ;
Snyman, DB ;
Swiegers, W .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 1997, 44 (06) :769-773