Comparison of COVID-19 laboratory diagnosis by commercial kits: Effectivity of RT-PCR to the RT-LAMP

被引:21
作者
Artik, Yakup [1 ,2 ,3 ]
Cosgun, Alp B. [2 ]
Cesur, Nevra P. [1 ,2 ]
Hizel, Nedret [2 ,4 ]
Uyar, Yavuz [2 ]
Sur, Haydar [5 ]
Ayan, Alp [3 ]
机构
[1] Univ Hlth Sci, Kanuni Sultan Suleyman Training & Res Hosp, COVID 19 Diagnost Ctr, Minist Hlth,Hlth Inst Turkey TUSEB, TR-34303 Istanbul, Kucukcekmece, Turkey
[2] COVID 19 Diagnost Ctr, Private Viromed Istanbul Cent Lab & Imaging Ctr, Istanbul, Sisli, Turkey
[3] Istanbul Kultur Univ, Fac Sci & Letters, Dept Mol Biol & Genet, Istanbul, Bakirkoy, Turkey
[4] Uskudar Univ, Fac Med, Med Biochem, Istanbul, Uskudar, Turkey
[5] Uskudar Univ, Fac Med, Dept Publ Hlth, Istanbul, Uskudar, Turkey
关键词
Coronavirus; Covid-19; LAMP-PCR; q-RT-PCR; SARS-CoV-2; SARS-COV-2;
D O I
10.1002/jmv.27559
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Coronavirus disease 2019 or COVID-19 caused by novel coronavirus/severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2 or 2019-nCoV) is an ongoing pandemic that has emerging global effects and requires rapid and reliable diagnostic testing. Quantitative reverse transcription-polymerase chain reaction (q-RT-PCR) is the gold standard method for SARS-CoV-2 detections. On the other hand, new approaches remedy the diagnosis difficulties gradually. Reverse transcription loop-mediated isothermal amplification (RT-LAMP) as one of these novel approaches may also contribute to faster and cheaper field-based testing. The present study was designed to evaluate this rapid screening diagnostic test that can give results in 30-45 min and to compare the effectiveness of LAMP to the q-RT-PCR. The 30 randomly chosen patient samples were generated by nasopharyngeal swabs with a portion of the SARS-CoV-2 nucleic sequence. The sample of quantification cycle (Cq) values was tested using RT-LAMP as well as by conventional q-RT-PCR. The patient samples were tested with four different kits (SENSObiz COVID-19 [SARS-CoV-2] LAMP Assay, the QIAseq DIRECT SARS-CoV-2 kit, Biospeedy SARS-CoV-2 Variant Plus kit, and CoVirion-CV19-2 SARS-CoV-2 OneStep RT-PCR kit) and two different PCR devices (GDS Rotor-Gene Q Thermocycler and Inovia Technologies GenX series). Based on 30 patient samples, the positive/negative ratio (P/N) was 30/0 as Biospeedy and Covirion (positivity 100%), 28/2 as Qiagen kit (positivity 93.3%) for the samples studied on the Inovia device while the same samples on the Rotor-Gene device were 30/0 as Biospeedy and Covirion (positivity 100%), 29/1 as Qiagen kit at the first day (96.7%). On the fifth day, the samples were studied in the Inovia device and the respective results were obtained: 27/3 as Biospeedy (positivity 90%), 16/14 as Qiagen (positivity 53.3%), 28/2 as Covirion kit (positivity 93.3%). When these samples were studied in the Rotor-Gene device, it was 29/1 in Biospeedy and Covirion (positivity 96.7%), 19/11 in the Qiagen kit (positivity 63.3%). When these samples were compared with the LAMP method it was found to be 19/11 (positivity 63.3%) on the first day and 18/12 (positivity 60%) on the fifth day. SARS-CoV-2 test studies will contribute to a proactive approach to the development of rapid diagnosis systems. The LAMP approach presents promising results to monitor exposed individuals and also improves screening efforts in potential ports of entry.
引用
收藏
页码:1998 / 2007
页数:10
相关论文
共 34 条
[1]  
Altindis M., 2017, J BIOTECHNOL STRATEG, V1, P11
[2]   A molecular test based on RT-LAMP for rapid, sensitive and inexpensive colorimetric detection of SARS-CoV-2 in clinical samples [J].
Amaral, Catarina ;
Antunes, Wilson ;
Moe, Elin ;
Duarte, Americo G. ;
Lima, Luis M. P. ;
Santos, Cristiana ;
Gomes, Ines L. ;
Afonso, Goncalo S. ;
Vieira, Ricardo ;
Teles, Helena Sofia S. ;
Reis, Marisa S. ;
Ramalho da Silva, Manuel A. ;
Henriques, Ana Margarida ;
Fevereiro, Miguel ;
Ventura, M. Rita ;
Serrano, Monica ;
Pimentel, Catarina .
SCIENTIFIC REPORTS, 2021, 11 (01)
[3]   The proximal origin of SARS-CoV-2 [J].
Andersen, Kristian G. ;
Rambaut, Andrew ;
Lipkin, W. Ian ;
Holmes, Edward C. ;
Garry, Robert F. .
NATURE MEDICINE, 2020, 26 (04) :450-452
[4]  
Artik Y., 2022, ELECTRON J GEN MED, V19
[5]  
Artik Y., 2021, AFET RISK DERGISI, DOI [10.35341/afet.977488, DOI 10.35341/AFET.977488]
[6]   Loop-mediated isothermal amplification (LAMP): An effective molecular point-of-care technique for the rapid diagnosis of coronavirus SARS-CoV-2 [J].
Chaouch, Melek .
REVIEWS IN MEDICAL VIROLOGY, 2021, 31 (06)
[7]   Detection of 2019 novel coronavirus (2019-nCoV) by real-time RT-PCR (Publication with Expression of Concern) [J].
Corman, Victor M. ;
Landt, Olfert ;
Kaiser, Marco ;
Molenkamp, Richard ;
Meijer, Adam ;
Chu, Daniel K. W. ;
Bleicker, Tobias ;
Bruenink, Sebastian ;
Schneider, Julia ;
Schmidt, Marie Luisa ;
Mulders, Daphne G. J. C. ;
Haagmans, Bart L. ;
van der Veer, Bas ;
van den Brink, Sharon ;
Wijsman, Lisa ;
Goderski, Gabriel ;
Romette, Jean-Louis ;
Ellis, Joanna ;
Zambon, Maria ;
Peiris, Malik ;
Goossens, Herman ;
Reusken, Chantal ;
Koopmans, Marion P. G. ;
Drosten, Christian .
EUROSURVEILLANCE, 2020, 25 (03) :23-30
[8]   A new immunosensor for breast cancer cell detection using antibody-coated long alkylsilane self-assembled monolayers in a parallel plate flow chamber [J].
Ehrhart, Jean-Claude ;
Bennetau, Bernard ;
Renaud, Louis ;
Madrange, Jean-Pierre ;
Thomas, Laurent ;
Morisot, Julie ;
Brosseau, Arnaud ;
Allano, Sylvain ;
Tauc, Patrick ;
Tran, Phuong-Lan .
BIOSENSORS & BIOELECTRONICS, 2008, 24 (03) :467-474
[9]   Smart materials-integrated sensor technologies for COVID-19 diagnosis [J].
Erdem, Ozgecan ;
Derin, Esma ;
Sagdic, Kutay ;
Yilmaz, Eylul Gulsen ;
Inci, Fatih .
EMERGENT MATERIALS, 2021, 4 (01) :169-185
[10]  
Gonzalez JM., 2020, IMMUNOLOGICAL SARS C