Dose Calculation Comparisons Between Monaco, Pinnacle and Eclipse Treatment Planning Systems

被引:0
作者
Bosse, C. [1 ]
Narayanasamy, G. [2 ]
Kirby, N. [1 ]
Mavroidis, P. [3 ]
Papanikolaou, N. [4 ]
Stathakis, S. [5 ]
机构
[1] Univ Texas Hlth Sci Ctr San Antonio, San Antonio, TX 78229 USA
[2] UTHSCSA, CME, DEPT, San Antonio, TX USA
[3] Univ N Carolina, Chapel Hill, NC USA
[4] Univ Texas HSC SA, San Antonio, TX USA
[5] Canc Therapy & Res Ctr S Texas, San Antonio, TX 78229 USA
关键词
D O I
10.1118/1.4924639
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
SU-E-T-277
引用
收藏
页码:3396 / 3397
页数:2
相关论文
共 50 条
[31]   Comparison of two algorithms for leaf motion calculation in eclipse treatment planning system [J].
Seoane, A. ;
Sanchez-Artunedo, D. .
RADIOTHERAPY AND ONCOLOGY, 2020, 152 :S766-S766
[32]   Development of a toolkit for dose verification and comparison between treatment planning systems [J].
Papanikolaou, N. ;
Liu, Y. ;
Stathakis, S. ;
Shi, C. .
MEDICAL PHYSICS, 2007, 34 (06) :2435-2436
[33]   Commissioning of Halcyon enhanced leaf model in the Eclipse treatment planning system: Focus on simple slit fields and VMAT dose calculation [J].
Miyasaka, Ryohei ;
Shirai, Mari ;
Igari, Mitsunobu ;
Kojima, Yume ;
Kozawa, Yuki ;
Kawachi, Toru ;
Hara, Ryusuke .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2025, 26 (06)
[34]   CALCULATION OF ELECTRON DOSE DISTRIBUTION FOR RADIOTHERAPY TREATMENT PLANNING [J].
KAWACHI, K .
PHYSICS IN MEDICINE AND BIOLOGY, 1975, 20 (04) :571-577
[35]   The effect of dose calculation accuracy on inverse treatment planning [J].
Jeraj, R ;
Keall, PJ ;
Siebers, JV .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (03) :391-407
[36]   Dose errors due to lung density variations in SBRT VMAT MONACO treatment planning system [J].
Corredoira, E. ;
Aza, Z. ;
Huertas, C. ;
Sanchez, F. ;
Huerga, C. ;
Ferrer, C. .
RADIOTHERAPY AND ONCOLOGY, 2018, 127 :S984-S985
[37]   COMPARISONS OF CONVENTIONAL AND CONTEMPORARY TREATMENT PLANNING SYSTEMS IN BRACHYTHERAPY [J].
Papagiannis, P. .
RADIOTHERAPY AND ONCOLOGY, 2011, 99 :S139-S140
[38]   Effect of computed tomography number-relative electron density conversion curve on the calculation of radiotherapy dose and evaluation of Monaco radiotherapy treatment planning system [J].
Mohsen Hasani ;
Bagher Farhood ;
Mahdi Ghorbani ;
Hamideh Naderi ;
Sepideh Saadatmand ;
Saeed Karimkhani Zandi ;
Courtney Knaup .
Australasian Physical & Engineering Sciences in Medicine, 2019, 42 :489-502
[39]   Effect of computed tomography number-relative electron density conversion curve on the calculation of radiotherapy dose and evaluation of Monaco radiotherapy treatment planning system [J].
Hasani, Mohsen ;
Farhood, Bagher ;
Ghorbani, Mahdi ;
Naderi, Hamideh ;
Saadatmand, Sepideh ;
Zandi, Saeed Karimkhani ;
Knaup, Courtney .
AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2019, 42 (02) :489-502
[40]   Evaluation of photon beam dose calculation accuracy of treatment planning systems using in vivo dosimetry [J].
Mohamed Ibrahim ;
Wahib MAttia ;
Khaled MElshahat .
OncologyandTranslationalMedicine, 2016, 2 (05) :234-238