Assessment of the wet area of a heat exchanger exposed to a water spray

被引:5
作者
Lacour, S. O. L. [1 ]
Trinquet, F. [1 ]
Vendee, P. E. [1 ]
Vallet, A. [1 ]
Delahaye, A. [1 ]
Fournaison, L. [1 ]
机构
[1] IRSTEA GPAN, 1 Rue Pierre Gilles de Gennes,CS 10030, F-92761 Antony, France
关键词
Spray cooling; Wet area; Thermal spray dispersion; Vapor/liquid equilibrium; Hygroscopic capacity of moist air; PERFORMANCE; SYSTEMS; FLOW; CFD; UPSTREAM; DROPLETS;
D O I
10.1016/j.applthermaleng.2017.09.030
中图分类号
O414.1 [热力学];
学科分类号
摘要
Evaporative spray cooling is widely used to increase heat transfer of air exchangers and improve their efficiency. However, exchanges inside the spray mixture are difficult to express as combined mass and heat are transferred between phases, resulting in difficulties for the design of spraying systems. In this paper, a model describing the 3D distribution of temperature and liquid content during the dispersion of a thermal spray was developed. A spray model was used to describe the first stage of water fragmentation. A Gaussian model including sedimentation of particles and wall effects was added to handle the dispersion process of the total water content. The microphysical part of the model results from energy and mass balances of water and air allowing local splitting between vapor and liquid content. Simulation results, comparing with temperature and humidity measurements for spray dispersion in a wind tunnel are in good agreement in various conditions of air temperature, humidity, velocity and water flow rate. Further analysis shows that the cooling is higher when the spray radius is close to the wind tunnel dimensions. The model was then used to compute the optimal distance between nozzle and exchanger in order to reach the highest efficiency. This position depends upon the nozzle hole and water-and-air flow rates. As evaporation is slow down when air becomes wetter, the remaining liquid droplets are deposited on the exchanger surface. The wet area was defined assuming a threshold value beyond which liquid flux clogs exchanger fins. Results showed that this area is sensitive not only to the dispersion radius, but also to the evaporation rate. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:434 / 443
页数:10
相关论文
共 30 条
  • [1] Modelling aerosol number distributions from a vehicle exhaust with an aerosol CFD model
    Albriet, B.
    Sartelet, K. N.
    Lacour, S.
    Carissimo, B.
    Seigneur, C.
    [J]. ATMOSPHERIC ENVIRONMENT, 2010, 44 (08) : 1126 - 1137
  • [2] Arya S.P., 1999, AIR POLLUTION METEOR
  • [3] Modeling of water spray evaporation: Application to passive cooling of buildings
    Belarbi, Rafik
    Ghiaus, Cristian
    Allard, Francis
    [J]. SOLAR ENERGY, 2006, 80 (12) : 1540 - 1552
  • [4] A numerical study of interacting buoyant cooling-tower plumes
    Bornoff, RB
    Mokhtarzadeh-Dehghan, MR
    [J]. ATMOSPHERIC ENVIRONMENT, 2001, 35 (03) : 589 - 598
  • [5] Enhancement of heat exchanges on a condenser using an air flow containing water droplets
    Boulet, P.
    Tissot, J.
    Trinquet, F.
    Fournaison, L.
    [J]. APPLIED THERMAL ENGINEERING, 2013, 50 (01) : 1164 - 1173
  • [6] Modelling atmospheric effects on performance and plume dispersal from natural draft wet cooling towers
    Chahine, A.
    Matharan, P.
    Wendum, D.
    Musson-Genon, L.
    Bresson, R.
    Carissimo, B.
    [J]. JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2015, 136 : 151 - 164
  • [7] A new approach to analysis and optimization of evaporative cooling system I: Theory
    Chen, Qun
    Yang, Kangding
    Wang, Moran
    Pan, Ning
    Guo, Zeng-Yuan
    [J]. ENERGY, 2010, 35 (06) : 2448 - 2454
  • [8] Numerical modeling of the drift and deposition of droplets emitted by mechanical cooling towers on buildings and its experimental validation
    Consuegro, A. J.
    Kaiser, A. S.
    Zamora, B.
    Sanchez, F.
    Lucas, M.
    Hernandez, M.
    [J]. BUILDING AND ENVIRONMENT, 2014, 78 : 53 - 67
  • [9] Indirect evaporative cooling potential in air-water systems in temperate climates
    Costelloe, B
    Finn, D
    [J]. ENERGY AND BUILDINGS, 2003, 35 (06) : 573 - 591
  • [10] Heat transfer correlations for low approach evaporative cooling systems in buildings
    Costelloe, B.
    Finn, D. P.
    [J]. APPLIED THERMAL ENGINEERING, 2009, 29 (01) : 105 - 115