Clinical Predictors of Recurrent Ventricular Arrhythmias in Secondary Prevention Implantable Cardioverter Defibrillator Recipients With Coronary Artery Disease - Lower Left Ventricular Ejection Fraction and Incomplete Revascularization -

被引:12
|
作者
Takano, Toshiki [1 ]
Tanaka, Komei [1 ]
Ozaki, Kazuyuki [1 ]
Sato, Akinori [1 ]
Iijima, Kenichi [1 ]
Yanagawa, Takao [1 ]
Izumi, Daisuke [1 ]
Ozawa, Takuya [1 ]
Fuse, Koichi [2 ]
Sato, Masahito [2 ]
Tanabe, Naohito [3 ]
Minamino, Tohru [1 ]
机构
[1] Niigata Univ, Grad Sch Med & Dent Sci, Dept Cardiovasc Biol & Med, Niigata, Japan
[2] Tachikawa Gen Hosp, Dept Cardiol, Niigata, Japan
[3] Univ Niigata Prefecture, Fac Human Life Studies, Dept Hlth & Nutr, Niigata, Japan
基金
日本学术振兴会;
关键词
Coronary artery disease; Implantable cardioverter defibrillator; Incomplete revascularization; Left ventricular ejection fraction; Ventricular arrhythmia; TERM-FOLLOW-UP; INTERVENTION; METAANALYSIS; OUTCOMES; THERAPY; RISK;
D O I
10.1253/circj.CJ-18-0646
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The implantable cardioverter defibrillator (ICD) is a standard prevention therapy for patients at high risk for sudden cardiac death (SCD) due to life-threatening ventricular arrhythmia (VA), that is, ventricular fibrillation and ventricular tachycardia. However, clinical predictors of recurrent VA in secondary prevention ICD recipients with coronary artery disease (CAD) remain unknown. Methods and Results: We followed up 96 consecutive patients with CAD undergoing ICD implantation for secondary prevention of SCD. Long-term rates and clinical predictors of appropriate ICD therapy (ICD-Tx) for VA were analyzed. Appropriate ICD-Tx occurred in 41 (42.7%) patients during a median follow-up of 2.4 years (interquartile range, 0.9-6.1). These patients had significantly greater left ventricular end-diastolic diameter (62.3 +/- 1.3 vs. 54.6 +/- 1.1 mm, P<0.001), lower left ventricular ejection fraction (LVEF; 36.3 +/- 2.0% vs. 45.7 +/- 1.8%, P<0.001), and more incomplete revascularization (ICR; 70.7% vs. 45.5%, P=0.014) than those without appropriate ICD-Tx. Multivariable analysis showed that LVEF (hazards ratio [HR], 0.950; 95% CI: 0.925-0.975; P<0.001) and ICR (HR, 2.293; 95% CI: 1.133-4.637; P=0.021) were significant predictors of appropriate ICD-Tx for VA. Conclusions: Lower LVEF and ICR were independent predictors of recurrent VA in secondary prevention ICD recipients with CAD.
引用
收藏
页码:3037 / 3043
页数:7
相关论文
共 50 条
  • [41] A prospective evaluation of catheter ablation of ventricular tachycardia as adjuvant therapy in patients with coronary artery disease and an implantable cardioverter-defibrillator
    Strickberger, SA
    Man, KC
    Daoud, EG
    Goyal, R
    Brinkman, K
    Hasse, C
    Bogun, F
    Knight, BP
    Weiss, R
    Bahu, M
    Morady, F
    CIRCULATION, 1997, 96 (05) : 1525 - 1531
  • [42] The Extent of Left Ventricular Scar Quantified by Late Gadolinium Enhancement MRI Is Associated With Spontaneous Ventricular Arrhythmias in Patients With Coronary Artery Disease and Implantable Cardioverter-Defibrillators
    Scott, Paul A.
    Morgan, John M.
    Carroll, Nicola
    Murday, David C.
    Roberts, Paul R.
    Peebles, Charles R.
    Harden, Stephen P.
    Curzen, Nick P.
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2011, 4 (03) : 324 - 330
  • [43] Cystatin C to Left Ventricular Ejection Fraction Ratio as a Novel Predictor of Adverse Outcomes in Patients with Coronary Artery Disease: A Prospective Cohort Study
    Ning, Yi
    Wang, Kai-Yang
    Min, Xuan
    Hou, Xian-Geng
    Wu, Ting-Ting
    Ma, Yi-Tong
    Xie, Xiang
    REVIEWS IN CARDIOVASCULAR MEDICINE, 2023, 24 (09)
  • [44] Clinical outcomes after primary prevention defibrillator implantation are better predicted when the left ventricular ejection fraction is assessed by cardiovascular magnetic resonance
    Champ-Rigot, Laure
    Gay, Pauline
    Seita, Frederic
    Benouda, Leila
    Morello, Remy
    Pellissier, Arnaud
    Alexandre, Joachim
    Saloux, Eric
    Milliez, Paul
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2020, 22 (01)
  • [45] Commentary: Implantable or wearable cardioverter defibrillator fi brillator after coronary artery bypass grafting in patients with left ventricular dysfunction?
    Murashita, Takashi
    JTCVS OPEN, 2023, 13 : 176 - 177
  • [46] Impact of Successful Chronic Coronary Total Occlusion Recanalization on Recurrence of Ventricular Arrhythmias in Implantable Cardioverter-Defibrillator Recipients for Ischemic Cardiomyopathy (VACTO PCI Study)
    Iannaccone, Mario
    Nombela-Franco, Luis
    Gallone, Guglielmo
    Annone, Umberto
    Di Marco, Andrea
    Giannini, Francesco
    Ayoub, Mohammed
    Sardone, Andrea
    Amat-Santos, Ignacio
    Fernandez-Lozano, Ignacio
    Barbero, Umberto
    Dusi, Veronica
    Toselli, Marco
    Petretta, Andrea
    de Salvia, Alberto
    Boccuzzi, Giacomo
    Colangelo, Salvatore
    Anguera, Ignasi
    D'Ascenzo, Fabrizio
    Colombo, Antonio
    De Ferrari, Gaetano Maria
    Escaned, Javier
    Garbo, Roberto
    Mashayekhi, Kambis
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2022, 43 : 104 - 111
  • [47] Effect of left ventricular systolic dysfunction on secondary medical prevention and clinical outcome in stable coronary artery disease patients
    Lamblin, Nicolas
    Meurice, Thibaud
    Tricot, Olivier
    Lemesle, Gilles
    Deneve, Michel
    de Groote, Pascal
    Bauters, Christophe
    ARCHIVES OF CARDIOVASCULAR DISEASES, 2017, 110 (01) : 35 - 41
  • [48] Associations between scar characteristics by cardiac magnetic resonance and changes in left ventricular ejection fraction in primary prevention defibrillator recipients
    Zhang, Yiyi
    Guallar, Eliseo
    Weiss, Robert G.
    Stillabower, Michael
    Gerstenblith, Gary
    Tomaselli, Gordon F.
    Wu, Katherine C.
    HEART RHYTHM, 2016, 13 (08) : 1661 - 1666
  • [49] Determinants of Left Ventricular Systolic Function Improvement Following Coronary Artery Revascularization in Heart Failure Patients With Reduced Ejection Fraction (HFrEF)
    Adachi, Yusuke
    Sakakura, Kenichi
    Wada, Hiroshi
    Funayama, Hiroshi
    Umemoto, Tomio
    Fujita, Hideo
    Momomura, Shin-ichi
    INTERNATIONAL HEART JOURNAL, 2016, 57 (05) : 565 - 572
  • [50] Relation of the Ankle Brachial Index to Left Ventricular Ejection Fraction in Patients Without Coronary Artery Disease
    Nunez, Arismendy
    Russ, Sophia
    Ihsan, Muhammad
    Gaballah, Sarah
    Haque, Attiya
    Goulbourne, Clive
    Railwah, Dale
    Massay, Ryan
    Khan, Muhammad Afzal
    Salciccioli, Louis
    Stewart, Mark
    Lazar, Jason M.
    CARDIOLOGY, 2018, 141 (01) : 18 - 24