Glassy carbon electrode modified with 3D graphene-carbon nanotube network for sensitive electrochemical determination of methotrexate

被引:105
|
作者
Asadian, Elham [1 ]
Shahrokhian, Saeed [1 ,2 ]
Zad, Azam Iraji [1 ,3 ]
Ghorbani-Bidkorbeh, Fatemeh [4 ]
机构
[1] Sharif Univ Technol, Inst Nanosci & Nanotechnol INST, Azadi Ave, Tehran, Iran
[2] Sharif Univ Technol, Dept Chem, Azadi Ave, Tehran 111559516, Iran
[3] Sharif Univ Technol, Dept Phys, Azadi Ave, Tehran 1458889694, Iran
[4] Shahid Beheshti Univ Med Sci, Sch Pharm, Dept Pharmaceut, Tehran, Iran
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2017年 / 239卷
关键词
3D-Network; Graphene; Carbon nanotube; Electrodeposition; Methotrexate; Voltammetry; OXIDE; HYBRID; SENSOR; ACID;
D O I
10.1016/j.snb.2016.08.064
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In the present study, a 3D porous graphene-carbon nanotube (G-CNT) network is successfully constructed on the surface of glassy carbon electrode (GCE) by electrochemical co-deposition from a concentrated graphene dispersion. The large accessible surface area provided by the interpenetrated graphene backbone in one hand and the enhanced electrical conductivity of the 3D network by incorporating CNTs on the other hand, dramatically improved the electrochemical performance of GCE in determination of Methotrexate (MTX) as an important electroactive drug compound. Under the optimum conditions, the electrode modification led to a significant increase in the anodic peak current (similar to 25 times) along with a considerable shift in the peak potential (similar to 111 mV). Voltammetric investigations revealed that the proposed method can determine MTX in a wide dynamic linear range with a low detection limit of 70 nM. Moreover, good sensitivity and high accuracy of the prepared modified electrode in voltammetric detections of MTX, which was further confirmed by UV-vis spectroscopy and HPLC methods, make it very suitable for accurate determinations of MTX in pharmaceutical formulations (commercial tablets) and clinical preparations (blood serum) with excellent recoveries. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:617 / 627
页数:11
相关论文
共 50 条
  • [41] Electrochemical Determination of Sulfonamide Based on Glassy Carbon Electrode Modified by Fe3O4/Functionalized Graphene
    He, Baoshan
    Yan, Sasa
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2017, 12 (04): : 3001 - 3011
  • [42] Sensitive Determination of Anticancer Drug Methotrexate Using Graphite Oxide-Nafion Modified Glassy Carbon Electrode
    Huang, Deqian
    Wu, Hai
    Zhu, Yuyang
    Su, Huijuan
    Zhang, Hong
    Sheng, Liangquan
    Liu, Zhaodi
    Xu, Huajie
    Song, Chongfu
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2019, 14 (04): : 3792 - 3804
  • [43] Electrochemical determination of adenine using a glassy carbon electrode modified with graphene oxide and polyaniline
    Vimal Sharma
    David Hynek
    Libuse Trnkova
    Dusan Hemzal
    Marian Marik
    Rene Kizek
    Jaromir Hubalek
    Microchimica Acta, 2016, 183 : 1299 - 1306
  • [44] ELECTROCHEMICAL DETERMINATION OF DOPAMINE WITH GRAPHENE-MODIFIED GLASSY CARBON ELECTRODES
    Szoke, Arpad Ferenc
    Turdean, Graziella Liana
    Katona, Gabriel
    Muresan, Liana Maria
    STUDIA UNIVERSITATIS BABES-BOLYAI CHEMIA, 2016, 61 (03): : 135 - 144
  • [45] Graphene Modified Glassy Carbon Electrode for Determination of Trace Aluminium(III) in Biological Samples
    Tang, Yongzheng
    Sun, Chong
    Yang, Xujie
    Yang, Xiaodi
    Shen, Ren Fang
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2013, 8 (03): : 4194 - 4205
  • [46] Electrochemical Determination of Morin in Natural Food Using a Chitosan-Graphene Glassy Carbon Modified Electrode
    Nagles, Edgar
    Bello, Monica
    Hurtado, John J.
    SENSORS, 2022, 22 (20)
  • [47] Sensitive Electrochemical Determination of Catechol with a Graphene Modified Carbon Ionic Liquid Electrode
    Ruan, Chengxiang
    Li, Tongtong
    Wang, Xiuzheng
    Qi, Xiaowei
    Lou, Jin
    Gao, Weimin
    Sun, Wei
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2012, 59 (12) : 1584 - 1590
  • [48] Electrochemical determination of dopamine and acetaminophen using activated graphene-Nafion modified glassy carbon electrode
    Kim, Dongwon
    Lee, Sohee
    Piao, Yuanzhe
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2017, 794 : 221 - 228
  • [49] Electrochemical Determination of 4-Nonylphenol Based on Graphene-Chitosan Modified Glassy Carbon Electrode
    Zhou Wen-Shu
    Zhao Bo
    Huang Xiao-Hua
    Yang Xiao-Di
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2013, 41 (05) : 675 - 680
  • [50] Electrochemical determination of nonylphenol using differential pulse voltammetry based on a graphene-DNA-modified glassy carbon electrode
    Zeng, Lixuan
    Zhang, Aizhen
    Zhu, Xiaohua
    Zhang, Chuyi
    Liang, Yong
    Nan, Junmin
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2013, 703 : 153 - 157