Optimizing the femoral component cement mantle in total hip arthroplasty

被引:0
|
作者
Dennis, DA [1 ]
Lynch, CB
机构
[1] Univ Tennessee, Dept Biomed Engn, Knoxville, TN 37996 USA
[2] Oakridge Natl Lab Univ Tennessee, Ctr Musculoskeletal Res, Knoxville, TN USA
[3] Rocky Mt Musculoskeletal Res Lab, Denver, CO USA
[4] Orthopaed Grp, New Haven, CT USA
关键词
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Aseptic loosening is a common cause of long-term failure of cemented femoral components in hip arthroplasty. Initiation of aseptic loosening has been associated with suboptimal cement mantle thickness and uniformity with the resultant progressive development of detrimental cement mantle defects. Long-term success is highly dependent on maintaining and protecting the integrity of the cement mantle and its interfaces primarily by decreasing cement mantle stresses. High cement stresses that initiate debonding and cement fracture can be controlled and minimized through the use of various surgical techniques that assist in creating an optimally thick, symmetric, and homogeneous cement mantle.
引用
收藏
页码:S867 / S871
页数:5
相关论文
共 50 条
  • [31] Fracture of the neck of a femoral component in a total hip arthroplasty: a case report
    V. Artime
    J. C. Ramos
    J. M. Fernandez-Medina
    M. C. de Luis
    L. Aguilera
    International Orthopaedics, 1997, 21 : 56 - 58
  • [32] ANALYSIS OF FEMORAL COMPONENT STEM DESIGN IN TOTAL HIP-ARTHROPLASTY
    CROWNINSHIELD, RD
    BRAND, RA
    JOHNSTON, RC
    MILROY, JC
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1980, 62 (01): : 68 - 78
  • [33] Cemented and uncemented total hip arthroplasty using the same femoral component
    Meding, John B.
    Ritter, Merrill A.
    Davis, Kenneth E.
    Hillery, Maggie
    HIP INTERNATIONAL, 2016, 26 (01) : 62 - 66
  • [34] Early outcome of a modular femoral component in revision total hip arthroplasty
    Kang, Michael N.
    Huddleston, James I.
    Hwang, Kathy
    Imrie, Susana
    Goodman, Stuart B.
    JOURNAL OF ARTHROPLASTY, 2008, 23 (02): : 220 - 225
  • [35] Fracture of the neck of a femoral component in a total hip arthroplasty: A case report
    Artime, V
    Ramos, JC
    FernandezMedina, JM
    deLuis, MC
    Aguilera, L
    INTERNATIONAL ORTHOPAEDICS, 1997, 21 (01) : 56 - 58
  • [37] FAILURE OF CEMENTLESS FIXATION OF THE FEMORAL COMPONENT IN TOTAL HIP-ARTHROPLASTY
    OTANI, T
    WHITESIDE, LA
    ORTHOPEDIC CLINICS OF NORTH AMERICA, 1992, 23 (02) : 335 - 346
  • [38] Dislodgement of the femoral component of a total hip arthroplasty presenting through the buttock
    Ashworth, MJ
    Dove, J
    JOURNAL OF ARTHROPLASTY, 1997, 12 (05): : 589 - 590
  • [39] Effect of femoral component offset on polyethylene wear in total hip arthroplasty
    Sakalkale, DP
    Sharkey, PF
    Eng, K
    Hozack, WJ
    Rothman, RH
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2001, (388) : 125 - 134
  • [40] NATURAL FIBER REINFORCED COMPOSITES FOR FEMORAL COMPONENT OF TOTAL HIP ARTHROPLASTY
    Asgari, S. A.
    Hamouda, A. M.
    Mansor, S. B.
    Mahdi, E.
    Wirza, R.
    Singh, H.
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2005, 5 (03) : 443 - 454