Real-time respiratory motion tracking: Roadmap correction for hepatic artery catheterizations

被引:7
|
作者
Atasoy, Selen [1 ]
Groher, Martin [1 ]
Zikic, Darko [1 ]
Glocker, Ben [1 ]
Waggershauser, Tobias
Pfister, Marcus [2 ]
Navab, Nassir [1 ]
机构
[1] Tech Univ Munich, CAMP, Boltzmannstr 3, D-85748 Garching, Germany
[2] LMU Grosshadern, Inst Clin Radiol, D-81337 Munich, Germany
来源
MEDICAL IMAGING 2008: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, PTS 1 AND 2 | 2008年 / 6918卷
关键词
abdominal procedures; intraoperative imaging;
D O I
10.1117/12.760985
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Nowadays, hepatic artery catheterizations are performed under live 2D X-ray fluoroscopy guidance, where the visualization of blood vessels requires the injection of contrast agent. The projection of a 3D static roadmap of the complex branches of the liver artery system onto 2D fluoroscopy images can aid catheter navigation and minimize the use of contrast agent. However, the presence of a significant hepatic motion due to patient's respiration necessitates a real-time motion correction in order to align the projected vessels. The objective of our work is to introduce dynamic roadmaps into clinical workflow for hepatic artery catheterizations and allow for continuous visualization of the vessels in 2D fluoroscopy images without additional contrast injection. To this end, we propose a method for real-time estimation of the apparent displacement of the hepatic arteries in 2D flouroscopy images. Our approach approximates respiratory motion of hepatic arteries from the catheter motion in 2D fluoroscopy images. The proposed method consists of two main steps. First, a filtering is applied to 2D fluoroscopy images in order to enhance the catheter and reduce the noise level. Then, a part of the catheter is tracked in the filtered images using template matching. A dynamic template update strategy makes our method robust to deformations. The accuracy and robustness of the algorithm are demonstrated by experimental studies on 22 simulated and 4 clinical sequences containing 330 and 571 image frames, respectively.
引用
收藏
页数:9
相关论文
共 2 条
  • [1] Real-time motion compensation for EM bronchoscope tracking with smooth output - ex-vivo validation
    Reichl, Tobias
    Gergel, Ingmar
    Menzel, Manuela
    Hautmann, Hubert
    Wegner, Ingmar
    Meinzer, Hans-Peter
    Navab, Nassir
    MEDICAL IMAGING 2012: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2012, 8316
  • [2] Real-time intraoperative fluorescence imaging system using light-absorption correction
    Themelis, George
    Yoo, Jung Sun
    Soh, Kwang-Sup
    Schulz, Ralf
    Ntziachristos, Vasilis
    JOURNAL OF BIOMEDICAL OPTICS, 2009, 14 (06)