Femur, tibia and fibula bone templates to estimate subject-specific knee ligament attachment site locations

被引:7
作者
Pillet, Helene [1 ]
Bergamini, Elena [2 ]
Rochcongar, Goulven [1 ,3 ]
Camomilla, Valentina [2 ]
Thoreux, Patricia [1 ,4 ]
Rouch, Philippe [1 ]
Cappozzo, Aurelio [2 ]
Skalli, Wafa [1 ]
机构
[1] Arts & Metiers ParisTech, Inst Biomecan Humaine Georges Charpak, Lab Biomecan LBM, 151 Bd Hosp, F-75013 Paris, France
[2] Univ Rome Foro Italico, Interuniv Ctr Bioengn Human Neuromusculoskeletal, Dept Movement Human & Hlth Sci, Rome, Italy
[3] Univ Caen, INSERM COMETE Mobil Attent Orientat & Chronobiol, Dept Orthopedie & Traumatol, F-14032 Caen, France
[4] Univ Paris 13, Hop Avicenne, Serv Chirurg Orthoped & Traumatol, Sorbonne Paris Cite, Bobigny, France
关键词
Knee ligaments; Ligament footprint; Bone templates; Generic model; Scaling; ANTERIOR CRUCIATE LIGAMENT; ANTHROPOMETRIC SCALING METHOD; MEDIAL COLLATERAL LIGAMENT; LOWER-LIMB; MULTIBODY OPTIMIZATION; JOINT; RECONSTRUCTION; KINEMATICS; ANATOMY; CALIBRATION;
D O I
10.1016/j.jbiomech.2016.09.027
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
In-vivo estimates of the positions of knee ligament attachment sites are crucial for subject-specific knee modelling. The present study provides template digital models of femur, tibia and fibula that embed the positions of centroids of the origins and insertions of cruciate and collateral ligaments, along with information on their dispersion related to inter-individual variability. By using a shape transformation procedure of choice, these templates can be made to match anatomical information measured on a subject under analysis. Generic bone digital models of the femur, tibia and fibula were first chosen as bone templates. Ligament attachment areas were accurately identified through dissection on the bones of 11 knee specimens, and marked using radio opaque paint. Digital models of these bones embedding the positions of the centroids of the identified ligament attachment areas were thereafter obtained using medical imaging techniques. These centroids were mapped onto the relevant bone template, thus obtaining a cloud of 11 points for each attachment site, and descriptive statistics of the position of these points were thereafter determined. Dispersion of these positions, essentially due to inter-individual variability, was below 6 mm for all attachment areas. The accuracy with which subject-specific ligament attachment site positions may be estimated using the bone template models provided in this paper was also assessed using the above-mentioned 11 specimens data set, and a leave-one-out cross validation approach. Average accuracy was found to be 3.3 +/- 1.5 mm and 5.8 +/- 2.9 mm for femoral and tibial/fibular attachment sites, respectively. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3523 / 3528
页数:6
相关论文
共 40 条
[1]   A procedure to estimate the origins and the insertions of the knee ligaments from computed tomography images [J].
Ascani, Daniele ;
Mazza, Claudia ;
De Lollis, Angelo ;
Bernardoni, Massimiliano ;
Viceconti, Marco .
JOURNAL OF BIOMECHANICS, 2015, 48 (02) :233-237
[2]   Radiograph processing for quantitative assessment of bone remodelling [J].
Audenino, AL ;
Zanetti, EM ;
Calderale, PM .
MEDICAL ENGINEERING & PHYSICS, 1996, 18 (05) :382-389
[3]   Tibio-femoral joint constraints for bone pose estimation during movement using multi-body optimization [J].
Bergamini, E. ;
Pillet, H. ;
Hausselle, J. ;
Thoreux, P. ;
Guerard, S. ;
Camomilla, V. ;
Cappozzo, A. ;
Skalli, W. .
GAIT & POSTURE, 2011, 33 (04) :706-711
[4]   A MODEL OF LOWER-EXTREMITY MUSCULAR ANATOMY [J].
BRAND, RA ;
CROWNINSHIELD, RD ;
WITTSTOCK, CE ;
PEDERSEN, DR ;
CLARK, CR ;
VANKRIEKEN, FM .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1982, 104 (04) :304-310
[5]   Fast 3D reconstruction of the lower limb using a parametric model and statistical inferences and clinical measurements calculation from biplanar X-rays [J].
Chaibi, Y. ;
Cresson, T. ;
Aubert, B. ;
Hausselle, J. ;
Neyret, P. ;
Hauger, O. ;
de Guise, J. A. ;
Skalli, W. .
COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2012, 15 (05) :457-466
[6]   Soft tissue artifact compensation in knee kinematics by multi-body optimization: Performance of subject-specific knee joint models [J].
Clement, Julien ;
Dumas, Raphael ;
Hagemeister, Nicola ;
de Guise, Jaques A. .
JOURNAL OF BIOMECHANICS, 2015, 48 (14) :3796-3802
[7]   Sequential 3D analysis of patellofemoral kinematics from biplanar x-rays: In vitro validation protocol [J].
Dagneaux, L. ;
Thoreux, P. ;
Eustache, B. ;
Canovas, F. ;
Skalli, W. .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2015, 101 (07) :811-818
[8]   Pelvis and lower limb anatomical landmark calibration precision and its propagation to bone geometry and joint angles [J].
Della Croce, U ;
Cappozzo, A ;
Kerrigan, DC .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1999, 37 (02) :155-161
[9]   Lateral radiographic study of the tibial sagital insertions of the anteromedial and posterolateral bundles of human anterior cruciate ligament [J].
Doi, Mitsuhito ;
Takahashi, Masaaki ;
Abe, Masashi ;
Suzuki, Daisuke ;
Nagano, Akira .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2009, 17 (04) :347-351
[10]   Anatomical frame identification and reconstruction for repeatable lower limb joint kinematics estimates [J].
Donati, Marco ;
Camomilla, Valentina ;
Vannozzi, Giuseppe ;
Cappozzo, Aurelio .
JOURNAL OF BIOMECHANICS, 2008, 41 (10) :2219-2226