Size Distribution of Air Bubbles Entering the Brain during Cardiac Surgery

被引:45
作者
Chung, Emma M. L. [1 ,2 ,3 ]
Banahan, Caroline [1 ,2 ]
Patel, Nikil [1 ,3 ]
Janus, Justyna [1 ]
Marshall, David [1 ,3 ]
Horsfield, Mark A. [1 ]
Rousseau, Clement [3 ]
Keelan, Jonathan [4 ]
Evans, David H. [1 ]
Hague, James P. [4 ]
机构
[1] Univ Leicester, Dept Cardiovasc Sci, Leicester, Leics, England
[2] Univ Hosp Leicester NHS Trust, Leicester, Leics, England
[3] Leicester Cardiovasc Biomed Res Unit, Leicester, Leics, England
[4] Open Univ, Dept Phys Sci, Milton Keynes MK7 6AA, Bucks, England
基金
英国工程与自然科学研究理事会;
关键词
CARBON-DIOXIDE INSUFFLATION; GASEOUS EMBOLI; BYPASS; TRIAL; BLOOD;
D O I
10.1371/journal.pone.0122166
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background Thousands of air bubbles enter the cerebral circulation during cardiac surgery, but whether high numbers of bubbles explain post-operative cognitive decline is currently controversial. This study estimates the size distribution of air bubbles and volume of air entering the cerebral arteries intra-operatively based on analysis of transcranial Doppler ultrasound data. Methods Transcranial Doppler ultrasound recordings from ten patients undergoing heart surgery were analysed for the presence of embolic signals. The backscattered intensity of each embolic signal was modelled based on ultrasound scattering theory to provide an estimate of bubble diameter. The impact of showers of bubbles on cerebral blood-flow was then investigated using patient-specific Monte-Carlo simulations to model the accumulation and clearance of bubbles within a model vasculature. Results Analysis of Doppler ultrasound recordings revealed a minimum of 371 and maximum of 6476 bubbles entering the middle cerebral artery territories during surgery. This was estimated to correspond to a total volume of air ranging between 0.003 and 0.12 mL. Based on analysis of a total of 18667 embolic signals, the median diameter of bubbles entering the cerebral arteries was 33 mu m (IQR: 18 to 69 mu m). Although bubble diameters ranged from similar to 5 mu m to 3.5 mm, the majority (85%) were less than 100 mu m. Numerous small bubbles detected during cardiopulmonary bypass were estimated by Monte-Carlo simulation to be benign. However, during weaning from bypass, showers containing large macro-bubbles were observed, which were estimated to transiently affect up to 2.2% of arterioles. Conclusions Detailed analysis of Doppler ultrasound data can be used to provide an estimate of bubble diameter, total volume of air, and the likely impact of embolic showers on cerebral blood flow. Although bubbles are alarmingly numerous during surgery, our simulations suggest that the majority of bubbles are too small to be harmful.
引用
收藏
页数:11
相关论文
共 15 条
[1]   SIZING GASEOUS EMBOLI USING DOPPLER EMBOLIC SIGNAL INTENSITY [J].
Banahan, Caroline ;
Hague, James P. ;
Evans, David H. ;
Patel, Rizwan ;
Ramnarine, Kumar V. ;
Chung, Emma M. L. .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2012, 38 (05) :824-833
[2]   Microbubbles - Pathophysiology and clinical implications [J].
Barak, M ;
Katz, Y .
CHEST, 2005, 128 (04) :2918-2932
[3]   Carbon dioxide insufflation in open-chamber cardiac surgery: A double-blind, randomized clinical trial of neurocognitive effects [J].
Chaudhuri, Krish ;
Storey, Elsdon ;
Lee, Geraldine A. ;
Bailey, Michael ;
Chan, Justin ;
Rosenfeldt, Franklin L. ;
Pick, Adrian ;
Negri, Justin ;
Gooi, Julian ;
Zimmet, Adam ;
Esmore, Donald ;
Merry, Chris ;
Rowland, Michael ;
Lin, Enjarn ;
Marasco, Silvana F. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2012, 144 (03) :646-+
[4]   The Effect of Carbon Dioxide Insufflation on Cognitive Function During Cardiac Surgery [J].
Chaudhuri, Krishanu ;
Marasco, Silvana F. .
JOURNAL OF CARDIAC SURGERY, 2011, 26 (02) :189-196
[5]   Revealing the mechanisms underlying embolic stroke using computational modelling [J].
Chung, Emma M. L. ;
Hague, James P. ;
Evans, David H. .
PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (23) :7153-7166
[6]   Protecting the brain from gaseous and solid micro-emboli during coronary artery bypass grafting: a randomized controlled trial [J].
Gerriets, Tibo ;
Schwarz, Niko ;
Sammer, Gebhard ;
Baehr, Jeanette ;
Stolz, Erwin ;
Kaps, Manfred ;
Kloevekorn, Wolf-Peter ;
Bachmann, Georg ;
Schoenburg, Markus .
EUROPEAN HEART JOURNAL, 2010, 31 (03) :360-368
[7]   Modelling of impaired cerebral blood flow due to gaseous emboli [J].
Hague, J. P. ;
Banahan, C. ;
Chung, E. M. L. .
PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (13) :4381-4394
[8]   Statistical physics of cerebral embolization leading to stroke [J].
Hague, J. P. ;
Chung, E. M. L. .
PHYSICAL REVIEW E, 2009, 80 (05)
[9]   Microembolism and Catheter Ablation II Effects of Cerebral Microemboli Injection in a Canine Model [J].
Haines, David E. ;
Stewart, Mark T. ;
Barka, Noah D. ;
Kirchhof, Nicole ;
Lentz, Linnea R. ;
Reinking, Nicki M. ;
Urban, Jon F. ;
Halimi, Franck ;
Deneke, Thomas ;
Kanal, Emanuel .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2013, 6 (01) :23-30
[10]   The (Un) Importance of Cerebral Microemboli [J].
Kruis, Rosalie W. J. ;
Vlasveld, Florine A. E. ;
Van Dijk, Diederik .
SEMINARS IN CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2010, 14 (02) :111-118