On the resolution of plenoptic PIV

被引:46
|
作者
Deem, Eric A. [1 ]
Zhang, Yang [1 ]
Cattafesta, Louis N. [1 ]
Fahringer, Timothy W. [2 ]
Thurow, Brian S. [2 ]
机构
[1] Florida State Univ, Florida Ctr Adv Aeroprop, Tallahassee, FL 32306 USA
[2] Auburn Univ, Adv Flow Diagnost, Auburn, AL 36849 USA
关键词
particle image velocimetry; PIV; plenoptic; aerodynamics; fluid mechanics;
D O I
10.1088/0957-0233/27/8/084003
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Plenoptic PIV offers a simple, single camera solution for volumetric velocity measurements of fluid flow. However, due to the novel manner in which the particle images are acquired and processed, few references exist to aid in determining the resolution limits of the measurements. This manuscript provides a framework for determining the spatial resolution of plenoptic PIV based on camera design and experimental parameters. This information can then be used to determine the smallest length scales of flows that are observable by plenoptic PIV, the dynamic range of plenoptic PIV, and the corresponding uncertainty in plenoptic PIV measurements. A simplified plenoptic camera is illustrated to provide the reader with a working knowledge of the method in which the light field is recorded. Then, operational considerations are addressed. This includes a derivation of the depth resolution in terms of the design parameters of the camera. Simulated volume reconstructions are presented to validate the derived limits. It is found that, while determining the lateral resolution is relatively straightforward, many factors affect the resolution along the optical axis. These factors are addressed and suggestions are proposed for improving performance.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Filtered refocusing: a volumetric reconstruction algorithm for plenoptic-PIV
    Fahringer, Timothy W.
    Thurow, Brian S.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2016, 27 (09)
  • [2] OPTIMAL DEPTH RESOLUTION IN PLENOPTIC IMAGING
    Drazic, Valter
    2010 IEEE INTERNATIONAL CONFERENCE ON MULTIMEDIA AND EXPO (ICME 2010), 2010, : 1588 - 1593
  • [3] DEPTH AND ANGULAR RESOLUTION IN PLENOPTIC CAMERAS
    Damghanian, M.
    Olsson, R.
    Sjostrom, M.
    2015 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING (ICIP), 2015, : 3044 - 3048
  • [4] Spatial resolution comparison of a diffractive plenoptic camera and an intermediate image diffractive plenoptic camera
    Diaz, Carlos D.
    Franz, Anthony L.
    Marciniak, Michael A.
    OPTICAL ENGINEERING, 2019, 58 (12)
  • [5] Feasibility and accuracy assessment of light field (plenoptic) PIV flow-measurement technique
    Shekhar, Chandra
    Ogawa, Syo
    Kawaguchi, Tatsuya
    EXPERIMENTAL FLUID MECHANICS 2016 (EFM16 ), 2017, 143
  • [6] Adaptive space resolution for PIV
    Astarita, T.
    EXPERIMENTS IN FLUIDS, 2009, 46 (06) : 1115 - 1123
  • [7] SPATIAL RESOLUTION IN A MULTI-FOCUS PLENOPTIC CAMERA
    Damghanian, M.
    Olsson, R.
    Sjostrom, M.
    Erdmann, A.
    Perwass, C.
    2014 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING (ICIP), 2014, : 1932 - 1936
  • [8] Adaptive space resolution for PIV
    T. Astarita
    Experiments in Fluids, 2009, 46
  • [9] A method of Plenoptic imaging with high resolution in turbulent atmosphere
    Lv, Yang
    Ma, Haotong
    Zhang, Xuanzhe
    Ning, Yu
    Xu, Xiaojun
    AOPC 2017: OPTICAL SENSING AND IMAGING TECHNOLOGY AND APPLICATIONS, 2017, 10462
  • [10] Super-Resolution in Plenoptic Cameras Using FPGAs
    Perez, Joel
    Magdaleno, Eduardo
    Perez, Fernando
    Rodriguez, Manuel
    Hernandez, David
    Corrales, Jaime
    SENSORS, 2014, 14 (05) : 8669 - 8685