Clinical abdominal dual-energy CT: 15 years later

被引:10
作者
Megibow, Alec J. [1 ]
机构
[1] NYU Langone Hlth, Dept Radiol, 550 1st Ave,Rm HCC 232, New York, NY 10016 USA
关键词
Dual Energy CT; Current technology; Integration; VIRTUAL NON-CONTRAST; IMAGES;
D O I
10.1007/s00261-019-02250-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Dual-energy CT (DECT) has been available for clinical use in the United States for close to 15 years. Although multiple applications in all areas of the body have been described that are only possible with DECT, the adoption into clinical practice has been slow. This paper will attempt to address many of the impediments the author has encountered from his discussions with radiologists across the country. A hopeful outcome would result in more practices adopting more DECT into their CT practices.
引用
收藏
页码:1198 / 1201
页数:4
相关论文
共 10 条
[1]  
Canellas Rodrigo, 2018, Radiol Bras, V51, P377, DOI 10.1590/0100-3984.2017.0136
[2]   Diagnostic accuracy of virtual non-contrast enhanced dual-energy CT for diagnosis of adrenal adenoma: A systematic review and meta-analysis [J].
Connolly, Michael J. ;
McInnes, Matthew D. F. ;
El-Khodary, Mohamed ;
McGrath, Trevor A. ;
Schieda, Nicola .
EUROPEAN RADIOLOGY, 2017, 27 (10) :4324-4335
[3]   Dual energy computed tomography virtual monoenergetic imaging: technique and clinical applications [J].
D'Angelo, Tommaso ;
Cicero, Giuseppe ;
Mazziotti, Silvio ;
Ascent, Giorgio ;
Albrecht, Moritz H. ;
Martin, Simon S. ;
Othman, Ahmed E. ;
Vogl, Thomas J. ;
Wichmann, Julian L. .
BRITISH JOURNAL OF RADIOLOGY, 2019, 92 (1098)
[4]   Assessment of an Advanced Image-Based Technique to Calculate Virtual Monoenergetic Computed Tomographic Images From a Dual-Energy Examination to Improve Contrast-To-Noise Ratio in Examinations Using Iodinated Contrast Media [J].
Grant, Katharine L. ;
Flohr, Thomas G. ;
Krauss, Bernhard ;
Sedlmair, Martin ;
Thomas, Christoph ;
Schmidt, Bernhard .
INVESTIGATIVE RADIOLOGY, 2014, 49 (09) :586-592
[5]  
Krupinski Elizabeth A, 2006, J Am Coll Radiol, V3, P433
[6]   Imaging the renal lesion with dual-energy multidetector CT and multi-energy applications in clinical practice: what can it truly do for you? [J].
Mileto, Achille ;
Sofue, Keitaro ;
Marin, Daniele .
EUROPEAN RADIOLOGY, 2016, 26 (10) :3677-3690
[7]   Assessment of 70-keV virtual monoenergetic spectral images in abdominal CT imaging: A comparison study to conventional polychromatic 120-kVp images [J].
Rassouli, Negin ;
Chalian, Hamid ;
Rajiah, Prabhakar ;
Dhanantwari, Amar ;
Landeras, Luis .
ABDOMINAL RADIOLOGY, 2017, 42 (10) :2579-2586
[8]   Evaluation of image quality and radiation dose of abdominal dual-energy CT [J].
Schmidt, David ;
Soderberg, Marcus ;
Nilsson, Mats ;
Lindvall, Hakan ;
Christoffersen, Christina ;
Leander, Peter .
ACTA RADIOLOGICA, 2018, 59 (07) :845-852
[9]   Virtual non-contrast in second-generation, dual-energy computed tomography: Reliability of attenuation values [J].
Toepker, Michael ;
Moritz, Thomas ;
Krauss, Bernhard ;
Weber, Michael ;
Euller, Gordon ;
Mang, Thomas ;
Wolf, Florian ;
Herold, Christian J. ;
Ringl, Helmut .
EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (03) :E398-E405
[10]   Advanced abdominal imaging with dual energy CT is feasible without increasing radiation dose [J].
Uhrig, Monika ;
Simons, David ;
Kachelriess, Marc ;
Pisana, Francesco ;
Kuchenbecker, Stefan ;
Schlemmer, Heinz-Peter .
CANCER IMAGING, 2016, 16