Polarimetry With a Multilayer CdTe Prototype for Soft Gamma-Ray Astrophysics

被引:2
作者
Moita, M. [1 ,2 ]
da Silva, R. M. Curado [2 ,3 ]
Maia, J. M. [2 ,4 ]
Caroli, E. [5 ]
Virgilli, E. [5 ]
Auricchio, N. [5 ]
Stephen, J. B. [5 ]
Frontera, F. [1 ]
del Sordo, S. [6 ]
机构
[1] Univ Ferrara, Dept Phys & Earth Sci, I-44122 Ferrara, Italy
[2] LIP Lab Instrumentacao & Fis Expt Particulas, P-3004516 Coimbra, Portugal
[3] Univ Coimbra, Phys Dept, P-3004516 Coimbra, Portugal
[4] Univ Beira Interior, Phys Dept, P-6201001 Covilha, Portugal
[5] OAS Bologna INAF Bologna, I-40129 Bologna, Italy
[6] IASF Palermo INAF Palermo, I-90146 Palermo, Italy
基金
欧盟地平线“2020”;
关键词
Compton scattering; CZT/cadmium telluride (CdTe); gamma-ray detectors; polarimetry; space instrumentation; HARD X-RAY; PROMPT EMISSION; POLARIZATION; PERFORMANCE; TELESCOPE; PULSAR;
D O I
10.1109/TNS.2021.3110472
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The development of a new generation of soft gamma-ray telescopes should allow polarimetric measurements of astrophysical sources to be associated with the results from spectroscopy and imaging due to the promising developments in polarimetry achieved over the last decade. In this perspective, the advanced surveyor of transient events and nuclear astrophysics mission which includes a narrow field telescope (NFT) that comprises a wide band Laue lens (60-600 keV) associated with a high performance thick and stacked CdZnTe focal plane operating as spectrometer, imager, and scattering polarimeter has been submitted for the ESA Voyage 2050 long term scientific planning preparation. In this context, and with the aim of optimizing the focal plane configuration of an instrument such as NFT, several studies are underway. In particular, with this work we study some performance issues such as polarimeters of segmented semiconductor detectors at room temperature, such as CdZnTe and cadmium telluride (CdTe), by means of a prototype based on two planar CdTe spectroimagers operating in coincidence. The two CdTe detectors are 2-mm-thick crystals with the anode segmented in 8 x 8 pixels with 2-mm pitch. This prototype configuration allows the Compton polarimetric performance of a spectroimager to be assessed by changing the distance between the two detection layers while operating in the 100-600-keV energy range, thereby allowing the analysis of Compton polarimetry 3-D dependence. The results obtained provide relevant input to the design of large sensitive volume multilayer and 3-D sensitive focal planes.
引用
收藏
页码:2655 / 2660
页数:6
相关论文
共 30 条
[1]   Multimessenger observations of a flaring blazar coincident with high-energy neutrino IceCube-170922A [J].
Aartsen, M. G. ;
Ackermann, M. ;
Adams, J. ;
Aguilar, J. A. ;
Ahlers, M. ;
Ahrens, M. ;
Al Samarai, I. ;
Altmann, D. ;
Andeen, K. ;
Anderson, T. ;
Ansseau, I. ;
Anton, G. ;
Arguelles, C. ;
Auffenberg, J. ;
Axani, S. ;
Bagherpour, H. ;
Bai, X. ;
Barron, J. P. ;
Barwick, S. W. ;
Baum, V. ;
Bay, R. ;
Beatty, J. J. ;
Tjus, J. Becker ;
Becker, K. -H. ;
BenZvi, S. ;
Berley, D. ;
Bernardini, E. ;
Besson, D. Z. ;
Binder, G. ;
Bindig, D. ;
Blaufuss, E. ;
Blot, S. ;
Bohm, C. ;
Borner, M. ;
Bos, F. ;
Boser, S. ;
Botner, O. ;
Bourbeau, E. ;
Bourbeau, J. ;
Bradascio, F. ;
Braun, J. ;
Brenzke, M. ;
Bretz, H. -P. ;
Bron, S. ;
Brostean-Kaiser, J. ;
Burgman, A. ;
Busse, R. S. ;
Carver, T. ;
Cheung, E. ;
Chirkin, D. .
SCIENCE, 2018, 361 (6398)
[2]   Multi-messenger Observations of a Binary Neutron Star Merger [J].
Abbott, B. P. ;
Abbott, R. ;
Abbott, T. D. ;
Acernese, F. ;
Ackley, K. ;
Adams, C. ;
Adams, T. ;
Addesso, P. ;
Adhikari, R. X. ;
Adya, V. B. ;
Affeldt, C. ;
Afrough, M. ;
Agarwal, B. ;
Agathos, M. ;
Agatsuma, K. ;
Aggarwal, N. ;
Aguiar, O. D. ;
Aiello, L. ;
Ain, A. ;
Ajith, P. ;
Allen, B. ;
Allen, G. ;
Allocca, A. ;
Altin, P. A. ;
Amato, A. ;
Ananyeva, A. ;
Anderson, S. B. ;
Anderson, W. G. ;
Angelova, S. V. ;
Antier, S. ;
Appert, S. ;
Arai, K. ;
Araya, M. C. ;
Areeda, J. S. ;
Arnaud, N. ;
Arun, K. G. ;
Ascenzi, S. ;
Ashton, G. ;
Ast, M. ;
Aston, S. M. ;
Astone, P. ;
Atallah, D. V. ;
Aufmuth, P. ;
Aulbert, C. ;
AultONeal, K. ;
Austin, C. ;
Avila-Alvarez, A. ;
Babak, S. ;
Bacon, P. ;
Bader, M. K. M. .
ASTROPHYSICAL JOURNAL LETTERS, 2017, 848 (02)
[3]   Hard X-ray polarimetry with Caliste, a high performance CdTe based imaging spectrometer [J].
Antier, S. ;
Ferrando, P. ;
Limousin, O. ;
Caroli, E. ;
Curado da Silva, R. M. ;
Blondel, C. ;
Chipaux, R. ;
Honkimaki, V. ;
Horeau, B. ;
Laurent, P. ;
Maia, J. M. ;
Meuris, A. ;
Del Sordo, S. ;
Stephen, J. B. .
EXPERIMENTAL ASTRONOMY, 2015, 39 (02) :233-258
[4]   Hard X-ray and Soft Gamma Ray Polarimetry with CdTe/CZT Spectro-Imager [J].
Caroli, Ezio ;
Moita, Miguel ;
Curado da Silva, Rui M. ;
Del Sordo, Stefano ;
de Cesare, Giovanni ;
Maia, Jorge M. ;
Pascoa, Marcela .
GALAXIES, 2018, 6 (03)
[5]  
Chattopadhyay T., ARXIV210405244
[6]   Polarization Degree and Direction Angle Effects on a CdZnTe Focal Plane Performance [J].
Curado da Silva, R. M. ;
Caroli, E. ;
Stephen, J. B. ;
Auricchio, N. ;
Maia, J. M. ;
Del Sordo, S. ;
Basili, A. ;
Schiavone, F. ;
Gloster, C. P. ;
Trindade, A. M. F. ;
Honkimaki, V. .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2012, 59 (04) :1628-1635
[7]   Polarimetric performance of a Laue lens gamma-ray CdZnTe focal plane prototype [J].
da Silva, R. M. Curado ;
Caroli, E. ;
Stephen, J. B. ;
Pisa, A. ;
Auricchio, N. ;
Del Sordo, S. ;
Frontera, F. ;
Honkimaki, V. ;
Schiavone, F. ;
Donati, A. ;
Trindade, A. M. F. ;
Ventura, G. .
JOURNAL OF APPLIED PHYSICS, 2008, 104 (08)
[8]   Polarimetric performance study of a CZT gamma-ray burst monitor concept [J].
da Silva, RMC ;
Caroli, E ;
Stephen, JB ;
Mendes, NFC ;
Frontera, F ;
Auricchio, N ;
Amati, L .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (01) :383-388
[9]   Hard X- and soft gamma-ray polarimetry with CdTe array prototypes [J].
da Silva, RMC ;
Auricchio, N ;
Caroli, E ;
Donati, A ;
Hage-Ali, M ;
Schiavone, F ;
Siffert, R ;
Stephen, JB ;
Ventura, G .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (05) :2478-2484
[10]  
Da Silva RMC, 2003, EXP ASTRON, V15, P45