Relationship between cortical bone thickness and implant stability at the time of surgery and secondary stability after osseointegration measured using resonance frequency analysis

被引:27
作者
Tanaka, Kenko [1 ,2 ,3 ]
Sailer, Irena [2 ]
Iwama, Ryosuke [1 ]
Yamauchi, Kensuke [1 ,3 ]
Nogami, Shinnosuke [1 ]
Yoda, Nobuhiro [3 ]
Takahashi, Tetsu [1 ,3 ]
机构
[1] Tohoku Univ, Div Oral & Maxillofacial Surg, Dept Oral Med & Surg, Grad Sch Dent, Sendai, Miyagi, Japan
[2] Dent Med Univ Geneva, Univ Clin, Div Fixed Prosthodont & Biomat, Geneva, Switzerland
[3] Tohoku Univ Hosp, Dent Implant Ctr, Sendai, Miyagi, Japan
关键词
Cortical bone thickness; Implant stability; Osseointegration; Resonance frequency analysis; TITANIUM IMPLANTS; LOADING PROTOCOLS; DENTAL IMPLANTS; OSSTELL MENTOR; GRAFTED BONE; DENSITY; SITES; OVERDENTURES; PLACEMENT; MAXILLA;
D O I
10.5051/jpis.2018.48.6.360
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: It has been suggested that resonance frequency analysis (RFA) can measure changes in the stability of dental implants during osseointegration. This retrospective study aimed to evaluate dental implant stability at the time of surgery (primary stability; PS) and secondary stability (SS) after ossseointegration using RFA, and to investigate the relationship between implant stability and cortical bone thickness. Methods: In total, 113 patients who attended the Tohoku University Hospital Dental Implant Center were included in this study. A total of 229 implants were placed in either the mandibular region (n=118) or the maxilla region (n=111), with bone augmentation procedures used in some cases. RFA was performed in 3 directions, and the lowest value was recorded. The preoperative thickness of cortical bone at the site of implant insertion was measured digitally using computed tomography, excluding cases of bone grafts and immediate implant placements. Results: The mean implant stability quotient (ISQ) was 69.34 +/- 9.43 for PS and 75.99 +/- 6.23 for SS. The mandibular group had significantly higher mean ISQ values than the maxillary group for both PS and SS (P<0.01). A significant difference was found in the mean ISQ values for PS between 1-stage and 2-stage surgery (P<0.5). The mean ISQ values in the non-augmentation group were higher than in the augmentation group for both PS and SS (P<0.01). A weak positive correlation was observed between cortical bone thickness and implant stability for both PS and SS in all cases (P<0.01). Conclusions: Based on the present study, the ISQ may be affected by implant position site, the use of a bone graft, and cortical bone thickness before implant therapy.
引用
收藏
页码:360 / 372
页数:13
相关论文
共 50 条
[21]   ASSESSMENT OF PRIMARY AND SECONDARY IMPLANT STABILITY BY RESONANCE FREQUENCY ANALYSIS IN ANTERIOR AND POSTERIOR SEGMENTS OF MAXILLARY EDENTULOUS RIDGES [J].
Baftijari, Denis ;
Benedetti, Alberto ;
Kirkov, Antonio ;
Iliev, Aleksandar ;
Stamatoski, Aleksandar ;
Baftijari, Florent ;
Deliverska, Elitsa G. ;
Gjorgievska, Elizabeta .
JOURNAL OF IMAB, 2018, 24 (02) :2058-2064
[22]   A resonance frequency analysis to investigate the impact of implant size on primary and secondary stability [J].
Khan, Mahvish Wahad ;
Inayat, Naveed ;
Zafar, Muhammad Sohail ;
Zaigham, Abdul Mueed .
PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2024, 40 (06) :1261-1266
[23]   Mathematical equations for dental implant stability patterns during the osseointegration period, based on previous resonance frequency analysis studies [J].
Charatchaiwanna, Attakorn ;
Rojsiraphisa, Thaned ;
Aunmeungtong, Weerapan ;
Reichart, Peter A. ;
Khongkhunthian, Pathawee .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2019, 21 (05) :1028-1040
[24]   Measurement of mini-implant stability using resonance frequency analysis [J].
Nienkemper, Manuel ;
Wilmes, Benedict ;
Panayotidis, Agamemnon ;
Pauls, Alexander ;
Golubovic, Vladimir ;
Schwarz, Frank ;
Drescher, Dieter .
ANGLE ORTHODONTIST, 2013, 83 (02) :230-238
[25]   Assessment of dental implant stability in osseodistraction-generated bone: a resonance frequency analysis [J].
Bilbao, Arturo ;
Hernandez-De Oliveira, M. ;
Varela-Centelles, Pablo I. ;
Seoane, J. .
CLINICAL ORAL IMPLANTS RESEARCH, 2009, 20 (08) :772-777
[26]   Evaluation of dental implant stability in bone phantoms: Comparison between a quantitative ultrasound technique and resonance frequency analysis [J].
Vayron, Romain ;
Vu-Hieu Nguyen ;
Lecuelle, Benoit ;
Haiat, Guillaume .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2018, 20 (04) :470-478
[27]   Implant Primary Stability Determined by Resonance Frequency Analysis: Correlation With Insertion Torque, Histologic Bone Volume, and Torsional Stability at 6 Weeks [J].
Makary, Christian ;
Rebaudi, Alberto ;
Sammartino, Gilberto ;
Naaman, Nada .
IMPLANT DENTISTRY, 2012, 21 (06) :474-480
[28]   Resonance Frequency Analysis: Agreement and Correlation of Implant Stability Quotients Between Three Commercially Available Instruments [J].
Norton, Michael R. .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2019, 34 (01) :215-222
[29]   The Relationship Between Peri-Implant Marginal Bone Loss and Resonance Frequency Analysis [J].
Perez-Pevida, Esteban ;
Monteagudo-Villalobos, Ivan ;
Chavarri-Prado, David ;
Estrada-Martinez, Alejandro ;
Beltran-Guijarro, Miguel ;
Dieguez-Pereira, Markel ;
Brizuela-Velasco, Aritza .
JOURNAL OF FUNCTIONAL BIOMATERIALS, 2025, 16 (02)
[30]   Resonance Frequency Analysis to Evaluate the Effect of Different Drilling Techniques on Implant Stability at Different Time Intervals: A Randomized Clinical Trial [J].
Sunny, Greeshma ;
Mishra, Sunil K. ;
Chowdhary, Ramesh .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2022, 37 (05) :1055-+