Two-Year Safety and Efficacy of Biodegradable Polymer Drug-Eluting Stent Versus Second-Generation Durable Polymer Drug-Eluting Stent in Patients With Acute Myocardial Infarction: Data from the Korea Acute Myocardial Infarction Registry (KAMIR)

被引:4
作者
Hur, Seung-Ho [1 ]
Kim, In-Cheol [1 ]
Won, Ki-Bum [1 ]
Cho, Yun-Kyeong [1 ]
Yoon, Hyuck-Jun [1 ]
Nam, Chang-Wook [1 ]
Kim, Kwon-Bae [1 ]
Kim, Min-Seok [2 ]
Park, Jincheol [2 ]
Rha, Seung-Woon [3 ]
Chae, Shung-Chull [4 ]
Kim, Young-Jo [5 ]
Kim, Chong-Jin [6 ]
Cho, Myeong-Chan [7 ]
Jeong, Myung-Ho [8 ]
Ahn, Young-Keun [8 ]
Kim, Hyo-Soo [9 ]
Ahn, Tae-Hoon [10 ]
Seung, Ki-Bae [11 ]
Jang, Yangsoo [12 ]
Yoon, Jung-Han [13 ]
Seong, In-Whan [14 ]
Hong, Taek-Jong [15 ]
Bae, Jang-Ho [16 ]
Park, Seung-Jung [17 ]
机构
[1] Keimyung Univ Dongsan, Div Cardiol, Med Ctr, 194 Dongsan Dong, Daegu, South Korea
[2] Keimyung Univ, Dept Stat, Daegu, South Korea
[3] Korea Univ, Guro Hosp, Div Cardiol, Seoul, South Korea
[4] Kyungpook Natl Univ Hosp, Div Cardiol, Daegu, South Korea
[5] Yeungnam Univ Hosp, Div Cardiol, Daegu, South Korea
[6] Kyung Hee Univ Hosp, Div Cardiol, Seoul, South Korea
[7] Chungbuk Natl Univ Hosp, Div Cardiol, Cheongju, South Korea
[8] Chonnam Natl Univ Hosp, Div Cardiol, Gwangju, South Korea
[9] Seoul Natl Univ Hosp, Div Cardiol, Seoul, South Korea
[10] Gachon Univ, Gil Hosp, Div Cardiol, Inchon, South Korea
[11] Catholic Univ Hosp, Div Cardiol, Seoul, South Korea
[12] Yonsei Univ, Severance Hosp, Div Cardiol, Seoul, South Korea
[13] Yonsei Univ, Wonju Hosp, Div Cardiol, Wonju, South Korea
[14] Chungnam Natl Univ Hosp, Div Cardiol, Daejeon, South Korea
[15] Busan Natl Univ Hosp, Div Cardiol, Busan, South Korea
[16] Konyang Univ Hosp, Div Cardiol, Daejeon, South Korea
[17] Univ Ulsan, Asan Med Ctr, Div Cardiol, Seoul, South Korea
关键词
BARE-METAL STENTS; PERCUTANEOUS CORONARY INTERVENTION; VASCULAR-RESPONSE; THROMBOSIS; METAANALYSIS; DISEASE; CYPHER;
D O I
10.1002/clc.22525
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Despite improved long-term safety of biodegradable polymer (BP) drug-eluting stents (DES) compared to first-generation durable polymer (DP) DES, data on the safety and efficacy of BP-DES compared with second-generation (2G) DP-DES in patients with acute myocardial infarction (AMI) are limited. Hypothesis: To evaluate the safety and efficacy of BP-DES compared with 2G-DP-DES in the higher stent thrombosis (ST) risk setting of AMI. Methods: A total of 3359 AMI patients who received either BP-DES (n=261) or 2G-DP-DES (n=3098) were included from the Korea Acute Myocardial Infarction Registry (KAMIR). Differences in baseline clinical and angiographic characteristics were adjusted using a 1:5 propensity score matching analysis (n=261 for BP-DES and n=1305 for 2G-DP-DES). The primary outcome was the incidence of major adverse cardiac events (MACE) including all-cause death, recurrent myocardial infarction (re-MI), and target vessel revascularization (TVR). The rate of definite or probable ST was also investigated. Results: In adjusted analysis, there was no significant difference between the 2 groups in baseline clinical and angiographic characteristics; 2-year MACE (10.7% and 9.9% in the BP-DES group and 2G-DP-DES group, respectively, P =0.679); ST incidence (0.8% vs 0.9%, respectively, P =1.0), and rates of all-cause death, re-MI, and TVR. By multivariate analysis, old age, diabetes mellitus, renal dysfunction, and left ventricular dysfunction were the independent predictors of MACE after BP-DES or 2G-DP-DES implantation. Conclusions: BP-DES and 2G-DP-DES appear to have comparable 2-year safety and efficacy for the treatment of AMI. However, longer-term follow-up is needed.
引用
收藏
页码:276 / 284
页数:9
相关论文
共 21 条
  • [1] Clinical end points in coronary stent trials - A case for standardized definitions
    Cutlip, Donald E.
    Windecker, Stephan
    Mehran, Roxana
    Boam, Ashley
    Cohen, David J.
    van Es, Gerrit-Anne
    Steg, P. Gabriel
    Morel, Marie-angele
    Mauri, Laura
    Vranckx, Pascal
    McFadden, Eugene
    Lansky, Alexandra
    Hamon, Martial
    Krucoff, Mitchell W.
    Serruys, Patrick W.
    [J]. CIRCULATION, 2007, 115 (17) : 2344 - 2351
  • [2] CORONARY MORPHOLOGICAL AND CLINICAL DETERMINANTS OF PROCEDURAL OUTCOME WITH ANGIOPLASTY FOR MULTIVESSEL CORONARY-DISEASE - IMPLICATIONS FOR PATIENT SELECTION
    ELLIS, SG
    VANDORMAEL, MG
    COWLEY, MJ
    DISCIASCIO, G
    DELIGONUL, U
    TOPOL, EJ
    BULLE, TM
    [J]. CIRCULATION, 1990, 82 (04) : 1193 - 1202
  • [3] Ho DE, 2011, J STAT SOFTW, V42
  • [4] Second-Generation Everolimus-Eluting Stents Versus First-Generation Sirolimus-Eluting Stents in Acute Myocardial Infarction 1-Year Results of the Randomized XAMI (XienceV Stent vs. Cypher Stent in Primary PCI for Acute Myocardial Infarction) Trial
    Hofma, Sjoerd H.
    Brouwer, Jan
    Velders, Matthijs A.
    van't Hof, Arnoud W. J.
    Smits, Pieter C.
    Quere, Michel
    de Vries, Cornelis Jan
    van Boven, Adrianus J.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 60 (05) : 381 - 387
  • [5] Long-Term Efficacy and Safety of Biodegradable-Polymer Biolimus-Eluting Stents Main Results of the Basel Stent Kosten-Effektivitats Trial-PROspective Validation Examination II (BASKET-PROVE II), A Randomized, Controlled Noninferiority 2-Year Outcome Trial
    Kaiser, Christoph
    Galatius, Soeren
    Jeger, Raban
    Gilgen, Nicole
    Jensen, Jan Skov
    Naber, Christoph
    Alber, Hannes
    Wanitschek, Maria
    Eberli, Franz
    Kurz, David J.
    Pedrazzini, Giovanni
    Moccetti, Tiziano
    Rickli, Hans
    Weilenmann, Daniel
    Vuillomenet, Andre
    Steiner, Martin
    Von Felten, Stefanie
    Vogt, Deborah R.
    Hansen, Kim Wadt
    Rickenbacher, Peter
    Conen, David
    Mueller, Christian
    Buser, Peter
    Hoffmann, Andreas
    Pfisterer, Matthias
    [J]. CIRCULATION, 2015, 131 (01) : 74 - 81
  • [6] Biodegradable-polymer drug-eluting stents vs. bare metal stents vs. durable-polymer drug-eluting stents: a systematic review and Bayesian approach network meta-analysis
    Kang, Si-Hyuck
    Park, Kyung Woo
    Kang, Do-Yoon
    Lim, Woo-Hyun
    Park, Kyung Taek
    Han, Jung-Kyu
    Kang, Hyun-Jae
    Koo, Bon-Kwon
    Oh, Byung-Hee
    Park, Young-Bae
    Kandzari, David E.
    Cohen, David J.
    Hwang, Seung-Sik
    Kim, Hyo-Soo
    [J]. EUROPEAN HEART JOURNAL, 2014, 35 (17) : 1147 - +
  • [7] Vascular Response to Drug-Eluting Stent With Biodegradable vs. Durable Polymer - Optical Coherence Tomography Substudy of the NEXT
    Kubo, Takashi
    Akasaka, Takashi
    Kozuma, Ken
    Kimura, Kazuo
    Fusazaki, Tetsuya
    Okura, Hiroyuki
    Shinke, Toshiro
    Ino, Yasushi
    Hasegawa, Takao
    Takashima, Hiroaki
    Takamisawa, Itaru
    Yamaguchi, Hiroshi
    Igarashi, Keiichi
    Kadota, Kazushige
    Tanabe, Kengo
    Nakagawa, Yoshihisa
    Muramatsu, Toshiya
    Morino, Yoshihiro
    Kimura, Takeshi
    [J]. CIRCULATION JOURNAL, 2014, 78 (10) : 2408 - 2414
  • [8] Clinical Outcomes of Biodegradable Polymer Drug-Eluting Stents for Percutaneous Coronary Intervention: An Updated Meta-analysis of Randomized Controlled Trials
    Kwong, Joey S. W.
    Yu, Cheuk-Man
    [J]. CLINICAL CARDIOLOGY, 2014, 37 (07) : 440 - 453
  • [9] The Safety and Efficacy of Absorb Bioresorbable Vascular Scaffold: A Systematic Review
    Lu, Chang
    Filion, Kristian B.
    Eisenberg, Mark J.
    [J]. CLINICAL CARDIOLOGY, 2016, 39 (01) : 48 - 55
  • [10] Estimation of coronary flow reserve using the thrombolysis in myocardial infarction (TIMI) frame count method
    Manginas, A
    Gatzov, P
    Chasikidis, C
    Voudris, V
    Pavlides, G
    Cokkinos, DV
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1999, 83 (11) : 1562 - +