A comparision of aspiration cytology and core needle biopsy according to tumor size of suspicious breast lesions

被引:34
作者
Barra, Alexandre De Almeida [1 ]
Gobbi, Helenice [2 ]
Rezende, Cesar Alencar de L. [1 ]
Gouvea, Agostinho Pinto [2 ]
Murta de Lucena, Clecio Enio [1 ]
Pena Reis, Joao Henrique [3 ]
Costa , Soraya Zhouri [1 ]
机构
[1] Univ Fed Minas Gerais, Dept Gynecol, Belo Horizonte, MG, Brazil
[2] Univ Fed Minas Gerais, Dept Pathol, Belo Horizonte, MG, Brazil
[3] Hosp Mater Dei, Dept Gynecol, Belo Horizonte, MG, Brazil
关键词
breast cancer; tumor size; fine-needle aspiration cytology; core biopsy;
D O I
10.1002/dc.20748
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
The purpose of the study was to compare the accuracy of FNAC, CNB, and combined biopsy according to tumor size of suspicious breast lesions. FNAC and CNB were performed in 264 patients with suspicious breast lesions from August, 1997 to August, 2002. The procedures were guided by ultrasound and performed in the same session by the same operator. The lesions were divided in four groups according to the tumor size in the histopathology report: lesions smaller than 1 cm, between 1 and 2 cm, between 2 and 5 cm, and lesions greater than 5 cm. The final surgical histopatology results identified 222 (84%) malignant cases and benign lesions summed 42 (16%). For lesions smaller than 1 cm, FNAC, CNB, and combined biopsy were equivalent for all parameters. For lesions between 1 and 2 cm, FNAC and CNB were equivalent. Combined biopsy showed higher absolute sensitivity (P = 0.007) and lower inadequate rate (P = 0.03) when compared to FNAC. However, when combined biopsy and CNB were compared, no difference were found. For lesions between 2 and 5 cm, CNB showed higher absolute sensitivity (P < 0.001) and lower inadequate rate (P < 0.007) when compared to FNAC. Combined biopsy showed higher sensitivity compared to FNAC and CNB alone (P < 0.05) in this group. For lesions greater than 5 cm, FNAC and CNB were equivalent for all parameters. Combined biopsy only showed higher absolute sensitivity (P = 0.04) when compared with FNAC alone. The combination of FNAC and CNB can improve the diagnosis of suspicious breast lesions higher than 1 cm. However, for lesions smaller than 1 cm, our results showed no difference between FNAC, CNB, and combined biopsy, for these lesions any modality has technical limitations.
引用
收藏
页码:26 / 31
页数:6
相关论文
共 27 条
[1]  
Abati A, 1996, ACTA CYTOL, V40, P1120
[2]  
[Anonymous], 1997, BREAST J, V3, P149
[3]  
Ballo MS, 1996, CANCER, V78, P773
[4]  
BARROWS GH, 1986, CANCER, V58, P1493, DOI 10.1002/1097-0142(19861001)58:7<1493::AID-CNCR2820580720>3.0.CO
[5]  
2-F
[6]   Changing to core biopsy in an NHS breast screening unit [J].
Britton, PD ;
Flower, CDR ;
Freeman, AH ;
Sinnatamby, R ;
Warren, R ;
Goddard, MJ ;
Wight, DGD ;
Bobrow, L .
CLINICAL RADIOLOGY, 1997, 52 (10) :764-767
[7]   Effectiveness of fine-needle aspiration cytology of breast: Analysis of 2,375 cases from northern Thailand [J].
Chaiwun, B ;
Settakorn, J ;
Ya-In, C ;
Wisedmongkol, W ;
Rangdaeng, S ;
Thorner, P .
DIAGNOSTIC CYTOPATHOLOGY, 2002, 26 (03) :201-205
[8]  
Clarke D, 2001, ANN ROY COLL SURG, V83, P110
[9]  
*CYT SUB GROUP NAT, 1992, GUID PROC REP BREAST
[10]   STEREOTAXIC CORE BIOPSY OF BREAST-LESIONS [J].
DRONKERS, DJ .
RADIOLOGY, 1992, 183 (03) :631-634