Adaptive neuro-fuzzy prediction of carbon monoxide emission from a clinical waste incineration plant

被引:31
作者
Norhayati, I. [1 ]
Rashid, M. [1 ]
机构
[1] UTM Kuala Lumpur, Malaysia Japan Int Inst Technol, Kuala Lumpur 54100, Malaysia
关键词
ANFIS; Continuous emission monitoring system; Model prediction; Incineration; Clinical waste; CO emission; NETWORK; ANFIS; IDENTIFICATION; MODEL;
D O I
10.1007/s00521-017-2921-z
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
The current practice of monitoring air emission from an incineration plant is through a hardware system known as Continuous Emission Monitoring Systems (CEMSs). Considering that CEMS suffers from high installation and maintenance cost, thus, the present work focuses on a modelling technique through an Adaptive Neuro-Fuzzy Inference System (ANFIS) to develop a predictive model of carbon monoxide (CO) emission utilizing actual data taken from a clinical waste incineration plant having capacity to process 250kg waste/h. An hourly averaged of 1000 data points consisted of nine input-output data pairs was utilized to develop a Sugeno-type fuzzy structure by applying subtractive clustering method. As the data were divided into three sets, i.e. 70% for training, 15% for checking and the rest for testing, the values of the coefficient of determination (R-2), root-mean-square error (RMSE), mean bias error (MBE) and accuracy (Ac) were calculated for each set to demonstrate its applicability and validity, emphasizing on the testing set since unseen data were exposed to the model. Result showed that ANFIS was able to learn from these data and excellently predicted the CO emission with R-2, RMSE, MBE and Ac of 0.98, 4.45, 0.66ppm and 87.98% in the testing set, respectively.
引用
收藏
页码:3049 / 3061
页数:13
相关论文
共 33 条
[1]   Emission control in palm oil mills using artificial neural network and genetic algorithm [J].
Ahmad, AL ;
Azid, IA ;
Yusof, AR ;
Seetharamu, KN .
COMPUTERS & CHEMICAL ENGINEERING, 2004, 28 (12) :2709-2715
[2]  
Al Shamisi M H, 2011, ENG ED RES USING MAT, P219, DOI DOI 10.1104/PP.17.01693
[3]  
Ambali AR., 2013, J Adm Sci, V10, P1
[4]  
Azid I.A., 2003, ASEAN J SCI TECHNOL, V20, P71, DOI DOI 10.29037/AJSTD.376
[5]  
Aziz IA, 2004, J MEK, V18, P66
[6]  
Baharun S., 2005, Jurnal Teknologi, V42, P11
[7]  
Baines G, 1999, IEEE IMTC P, P435, DOI 10.1109/IMTC.1999.776790
[8]   Safe disposal and effective destruction of clinical wastes [J].
Blenkharn, JI .
JOURNAL OF HOSPITAL INFECTION, 2005, 60 (04) :295-297
[9]  
Castellanos F., 2009, 11 AM C WIND ENG SAN
[10]   Adaptive fuzzy model identification to predict the heat transfer coefficient in pool boiling of distilled water [J].
Das, Mihir K. ;
Kishor, Nand .
EXPERT SYSTEMS WITH APPLICATIONS, 2009, 36 (02) :1142-1154