Evaluating performance in three-dimensional fluorescence microscopy

被引:84
作者
Murray, John M. [1 ]
Appleton, Paul L.
Swedlow, Jason R.
Waters, Jennifer C.
机构
[1] Univ Penn, Sch Med, Dept Cell & Dev Biol, Philadelphia, PA 19104 USA
[2] Univ Dundee, Coll Life Sci, Dept Cell & Dev Biol, Dundee DD1 5EH, Scotland
[3] Univ Dundee, Coll Life Sci, Div Gene Regulat & Express, Dundee DD1 5EH, Scotland
[4] Harvard Univ, Sch Med, Dept Cell Biol, Boston, MA 02115 USA
基金
英国惠康基金;
关键词
confocal microscopy; deconvolution; light throughput; photobleaching; signal to noise ration;
D O I
10.1111/j.1365-2818.2007.01861.x
中图分类号
TH742 [显微镜];
学科分类号
摘要
In biological fluorescence microscopy, image contrast is often degraded by a high background arising from out of focus regions of the specimen. This background can be greatly reduced or eliminated by several modes of thick specimen microscopy, including techniques such as 3-D deconvolution and confocal. There has been a great deal of interest and some confusion about which of these methods is 'better', in principle or in practice. The motivation for the experiments reported here is to establish some rough guidelines for choosing the most appropriate method of microscopy for a given biological specimen. The approach is to compare the efficiency of photon collection, the image contrast and the signal-to-noise ratio achieved by the different methods at equivalent illumination, using a specimen in which the amount of out of focus background is adjustable over the range encountered with biological samples. We compared spot scanning confocal, spinning disk confocal and wide-field/deconvolution (WFD) microscopes and find that the ratio of out of focus background to in-focus signal can be used to predict which method of microscopy will provide the most useful image. We also find that the precision of measurements of net fluorescence yield is very much lower than expected for all modes of microscopy. Our analysis enabled a clear, quantitative delineation of the appropriate use of different imaging modes relative to the ratio of out-of-focus background to in-focus signal, and defines an upper limit to the useful range of the three most common modes of imaging.
引用
收藏
页码:390 / 405
页数:16
相关论文
共 13 条
[1]  
CHONG FK, 2004, 3 DIMENSIONAL MULTID, P65
[2]   THEORETICAL-ANALYSIS OF A ROTATING-DISK PARTIALLY CONFOCAL SCANNING MICROSCOPE [J].
CONCHELLO, JA ;
LICHTMAN, JW .
APPLIED OPTICS, 1994, 33 (04) :585-596
[3]   Review - The fluorescent toolbox for assessing protein location and function [J].
Giepmans, BNG ;
Adams, SR ;
Ellisman, MH ;
Tsien, RY .
SCIENCE, 2006, 312 (5771) :217-224
[4]   Cytoskeletal components of an invasion machine -: The apical complex of Toxoplasma gondii [J].
Hu, Ke ;
Johnson, Jeff ;
Florens, Laurence ;
Fraunholz, Martin ;
Suravajjala, Sapna ;
DiLullo, Camille ;
Yates, John ;
Roos, David S. ;
Murray, John M. .
PLOS PATHOGENS, 2006, 2 (02) :121-138
[5]  
Murray JM, 1998, J MICROSC-OXFORD, V191, P128, DOI 10.1046/j.1365-2818.1998.00374.x
[6]   Photobleaching in two-photon excitation microscopy [J].
Patterson, GH ;
Piston, DW .
BIOPHYSICAL JOURNAL, 2000, 78 (04) :2159-2162
[7]  
Sandison David R., 1995, P39
[8]   QUANTITATIVE COMPARISON OF BACKGROUND REJECTION, SIGNAL-TO-NOISE RATIO, AND RESOLUTION IN CONFOCAL AND FULL-FIELD LASER-SCANNING MICROSCOPES [J].
SANDISON, DR ;
PISTON, DW ;
WILLIAMS, RM ;
WEBB, WW .
APPLIED OPTICS, 1995, 34 (19) :3576-3588
[9]   Feature point tracking and trajectory analysis for video imaging in cell biology [J].
Sbalzarini, IF ;
Koumoutsakos, P .
JOURNAL OF STRUCTURAL BIOLOGY, 2005, 151 (02) :182-195
[10]  
Shapiro HM, 2003, PRACTICAL FLOW CYTOM