False-Positive Axillary Lymph Nodes on FDG PET/CT Resulting From COVID-19 Immunization

被引:14
作者
Nawwar, Ayah Adel [1 ,2 ]
Searle, Julie [1 ,3 ]
Hopkins, Richard [1 ,3 ]
Lyburn, Iain Douglas [1 ,3 ,4 ]
机构
[1] Cobalt Med Char, Linton House,Thirlestaine Rd, Cheltenham GL53 7AS, Glos, England
[2] Cairo Univ, Clin Oncol & Nucl Med Dept, Cairo, Egypt
[3] Gloucestershire Hosp NHS Fdn Trust, Cheltenham, Glos, England
[4] Cranfield Univ Shrivenham, Cranfield Forens Inst, Swindon, Wilts, England
关键词
COVID-19; vaccination; F-18-FDG PET/CT; pitfall; axillary lymph nodes; inflammatory; reactive; VACCINATION; PITFALLS;
D O I
10.1097/RLU.0000000000003657
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
World-wide mass COVID-19 vaccination has been deployed starting with those most vulnerable, including the elderly and cancer patients. A 70-year-old man with right lung cancer underwent staging FDG PET/CT, which demonstrated an avid right lung mass with avid hilar and mediastinal nodes. Avid left axillary nodes of benign configuration were also noted. The patient had the Oxford-AstraZeneca COVID-19 vaccination in the left arm a week earlier. On reflection, the axillary nodes were concluded to be reactive related to this. This is a potential COVID-19 vaccination associated pitfall on PET/CT that should be considered when interpreting FDG PET/CT images. © 2020 Wolters Kluwer Health, Inc. All rights reserved.
引用
收藏
页码:1004 / 1005
页数:2
相关论文
共 9 条
[1]   Incidence and Intensity of F-18 FDG Uptake After Vaccination With H1N1 Vaccine [J].
Burger, Irene A. ;
Husmann, Lars ;
Hany, Thomas F. ;
Schmid, Daniel T. ;
Schaefer, Niklaus G. .
CLINICAL NUCLEAR MEDICINE, 2011, 36 (10) :848-853
[2]   Lymph Node Activation by PET/CT Following Vaccination With Licensed Vaccines for Human Papillomaviruses [J].
Coates, Emily E. ;
Costner, Pamela J. ;
Nason, Martha C. ;
Herrin, Douglas M. ;
Conant, Shielah ;
Herscovitch, Peter ;
Sarwar, Uzma N. ;
Holman, Lasonji ;
Mitchell, Jillian ;
Yamshchikov, Galina ;
Koup, Richard A. ;
Graham, Barney S. ;
Millo, Corina M. ;
Ledgerwood, Julie E. .
CLINICAL NUCLEAR MEDICINE, 2017, 42 (05) :329-334
[3]   Imaging of COVID-19 Vaccination at FDG PET/CT [J].
Eifer, Michal ;
Eshet, Yael .
RADIOLOGY, 2021, 299 (02) :E248-E248
[4]   The new 8th TNM staging system of lung cancer and its potential imaging interpretation pitfalls and limitations with CT image demonstrations [J].
Feng, Selena Hsin ;
Yang, Su-Tso .
DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2019, 25 (04) :270-279
[5]  
Long NM, 2011, INSIGHTS IMAGING, V2, P679, DOI 10.1007/s13244-010-0062-3
[6]   Axillary lymph node accumulation on FDG-PET/CT after influenza vaccination [J].
Shirone, Norihisa ;
Shinkai, Takayuki ;
Yamane, Tomohiko ;
Uto, Fumiaki ;
Yoshimura, Hitoshi ;
Tamai, Hiroyuki ;
Imai, Teruhiko ;
Inoue, Makoto ;
Kitano, Satoru ;
Kichikawa, Kimihiko ;
Hasegawa, Masatoshi .
ANNALS OF NUCLEAR MEDICINE, 2012, 26 (03) :248-252
[7]   Pitfalls in oncologic diagnosis with FDG PET imaging: Physiologic and benign variants [J].
Shreve, PD ;
Anzai, Y ;
Wahl, RL .
RADIOGRAPHICS, 1999, 19 (01) :61-77
[8]   False-positive axillary lymph node on FDG-PET/CT scan resulting from immunization [J].
Williams, Gethin ;
Joyce, Robin M. ;
Parker, J. Anthony .
CLINICAL NUCLEAR MEDICINE, 2006, 31 (11) :731-732
[9]   COVID-19 mRNA Vaccination-Induced Lymphadenopathy Mimics Lymphoma Progression on FDG PET/CT [J].
Xu, Guofan ;
Lu, Yang .