Proton transfer reaction mass spectrometry for the sensitive and rapid real-time detection of solid high explosives in air and water

被引:31
作者
Juerschik, S. [1 ]
Sulzer, P. [1 ]
Petersson, F. [1 ]
Mayhew, C. A. [2 ]
Jordan, A. [1 ]
Agarwal, B. [3 ]
Haidacher, S. [1 ]
Seehauser, H. [1 ]
Becker, K. [4 ]
Maerk, T. D. [1 ,3 ]
机构
[1] Ionicon Analyt Gesell mbH, A-6020 Innsbruck, Austria
[2] Univ Birmingham, Sch Phys & Astron, Mol Phys Grp, Birmingham B15 4TT, W Midlands, England
[3] Leopold Franzens Univ Innsbruck, Inst Ionenphys & Angew Phys, A-6020 Innsbruck, Austria
[4] NYU, Polytech Inst, Dept Phys, Brooklyn, NY 11201 USA
基金
英国工程与自然科学研究理事会;
关键词
PTR-MS; Trace compound detection; Explosives; TNT; Direct aqueous injection; MS;
D O I
10.1007/s00216-010-4114-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Relying on recent developments in proton transfer reaction mass spectrometry (PTR-MS), we demonstrate here the capability of detecting solid explosives in air and in water in real time. Two different proton transfer reaction mass spectrometers have been used in this study. One is the PTR-TOF 8000, which has an enhanced mass resolution (m/Delta m up to 8,000) and high sensitivity (similar to 50 cps/ppbv). The second is the high-sensitivity PTR-MS, which has an improved limit of detection of about several hundreds of parts per quadrillion by volume and is coupled with a direct aqueous injection device. These instruments have been successfully used to identify and monitor the solid explosive 2,4,6-trinitrotoluene (TNT) by analysing on the one hand the headspace above small quantities of samples at room temperature and from trace quantities not visible to the naked eye placed on surfaces (also demonstrating the usefulness of a simple pre-concentration and thermal desorption technique) and by analysing on the other hand trace compounds in water down to a level of about 100 pptw. The ability to identify even minute amounts of threat compounds, such as explosives, particularly within a complex chemical environment, is vital to the fight against crime and terrorism and is of paramount importance for the appraisal of the fate and harmful effects of TNT at marine ammunition dumping sites and the detection of buried antipersonnel and antitank landmines.
引用
收藏
页码:2813 / 2820
页数:8
相关论文
共 13 条
[1]   Membrane introduction proton-transfer reaction mass spectrometry [J].
Alexander, M ;
Boscaini, E ;
Lindinger, W ;
Märk, TD .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2003, 223 (1-3) :763-770
[2]  
[Anonymous], 2005, ION MOBILITY SPECTRO, DOI DOI 10.1201/9781420038972
[3]   Membrane inlet proton transfer reaction mass spectrometry (MI-PTRMS) for direct measurements of VOCs in water [J].
Boscaini, E ;
Alexander, ML ;
Prazeller, P ;
Märk, TD .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2004, 239 (2-3) :171-177
[4]   A high resolution and high sensitivity proton-transfer-reaction time-of-flight mass spectrometer (PTR-TOF-MS) [J].
Jordan, A. ;
Haidacher, S. ;
Hanel, G. ;
Hartungen, E. ;
Maerk, L. ;
Seehauser, H. ;
Schottkowsky, R. ;
Sulzer, P. ;
Maerk, T. D. .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2009, 286 (2-3) :122-128
[5]   An online ultra-high sensitivity Proton-transfer-reaction mass-spectrometer combined with switchable reagent ion capability (PTR+SRI-MS) [J].
Jordan, A. ;
Haidacher, S. ;
Hanel, G. ;
Hartungen, E. ;
Herbig, J. ;
Maerk, L. ;
Schottkowsky, R. ;
Seehauser, H. ;
Sulzer, P. ;
Maerk, T. D. .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2009, 286 (01) :32-38
[6]   Direct aqueous injection analysis of trace compounds in water with proton-transfer-reaction mass spectrometry (PTR-MS) [J].
Juerschik, S. ;
Tani, A. ;
Sulzer, P. ;
Haidacher, S. ;
Jordan, A. ;
Schottkowsky, R. ;
Hartungen, E. ;
Hanel, G. ;
Seehauser, H. ;
Maerk, L. ;
Maerk, T. D. .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2010, 289 (2-3) :173-176
[7]   Applications of proton transfer reaction time-of-flight mass spectrometry for the sensitive and rapid real-time detection of solid high explosives [J].
Mayhew, C. A. ;
Sulzer, P. ;
Petersson, F. ;
Haidacher, S. ;
Jordan, A. ;
Maerk, L. ;
Watts, P. ;
Maerk, T. D. .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2010, 289 (01) :58-63
[8]  
*NAT RES COUNC DIV, 2004, OPP IMPR AIRP PASS S
[9]   Real-time trace detection and identification of chemical warfare agent simulants using recent advances in proton transfer reaction time-of-flight mass spectrometry [J].
Petersson, Fredrik ;
Sulzer, Philipp ;
Mayhew, Chris A. ;
Watts, Peter ;
Jordan, Alfons ;
Maerk, Lukas ;
Maerk, Tilmann D. .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2009, 23 (23) :3875-3880
[10]   Treatment methods for the remediation of nitroaromatic explosives [J].
Rodgers, JD ;
Bunce, NJ .
WATER RESEARCH, 2001, 35 (09) :2101-2111