Retention of prefabricated attachments for implant stabilized overdentures in the edentulous mandible: An in vitro study

被引:80
作者
Setz, J [1 ]
Lee, SH [1 ]
Dent, M [1 ]
Engel, E [1 ]
机构
[1] Univ Tuebingen, Tuebingen, Germany
关键词
D O I
10.1016/S0022-3913(98)70133-7
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Bar and stud attachments are widely used to stabilize overdentures on implants in the mandible. There is strong evidence that retention of the attachment is an important factor for a patient's satisfaction. Purpose. This study describes retentive forces and wear of commercially available attachments of 4 implant systems (3I, IMZ, Nobel Biocare, ITI Straumann) and 2 magnets (Steco). Methods. Forces while removing the keyway portion of an attachment in its path of insertion were measured with a platform load cell. A total of 15,000 removals were performed to simulate fatigue. Results. Retentive forces ranged between 5 and 85 N. The fatigue test revealed an initial increase of forces with some attachments. After 15,000 cycles, most of the attachments showed little loss of retention compared with the initial retentive: forces. It is suggested that conventional fatigue tests with application of axial loads do not simulate clinical fatigue adequately.
引用
收藏
页码:323 / 329
页数:7
相关论文
共 38 条
[1]  
ADELL R, 1990, International Journal of Oral and Maxillofacial Implants, V5, P347
[2]  
Blomberg S, 1985, TISSUE INTEGRATED PR
[3]   The effect of simulated function on the retention of bar-clip retained removable prostheses [J].
Breeding, LC ;
Dixon, DL ;
Schmitt, S .
JOURNAL OF PROSTHETIC DENTISTRY, 1996, 75 (05) :570-573
[4]   PROSPECTIVE CLINICAL-EVALUATION OF MANDIBULAR IMPLANT OVERDENTURES .1. RETENTION, STABILITY, AND TISSUE-RESPONSE [J].
BURNS, DR ;
UNGER, JW ;
ELSWICK, RK ;
BECK, DA .
JOURNAL OF PROSTHETIC DENTISTRY, 1995, 73 (04) :354-363
[5]   PROSPECTIVE CLINICAL-EVALUATION OF MANDIBULAR IMPLANT OVERDENTURES .2. PATIENT SATISFACTION AND PREFERENCE [J].
BURNS, DR ;
UNGER, JW ;
ELSWICK, RK ;
GIGLIO, JA .
JOURNAL OF PROSTHETIC DENTISTRY, 1995, 73 (04) :364-369
[6]  
Chan M F, 1996, Eur J Prosthodont Restor Dent, V4, P39
[7]  
Chao Y L, 1995, Eur J Prosthodont Restor Dent, V3, P255
[8]   Comparative study of two precision overdenture attachment designs [J].
Cohen, BI ;
Pagnillo, M ;
Condos, S ;
Deutsch, AS .
JOURNAL OF PROSTHETIC DENTISTRY, 1996, 76 (02) :145-152
[9]   BAR JOINT MANDIBULAR DENTURE [J].
DOLDER, EJ .
JOURNAL OF PROSTHETIC DENTISTRY, 1961, 11 (04) :689-&
[10]  
Dolder EJ, 1978, BAR JOINT DENTURE