Determination of cyclosporine, tacrolimus, sirolimus and everolimus by liquid chromatography coupled to electrospray ionization and tandem mass spectrometry: Assessment of matrix effects and assay performance

被引:20
|
作者
Vethe, Nils T. [1 ]
Gjerdalen, Laila C. [1 ]
Bergan, Stein [2 ,3 ]
机构
[1] Natl Hosp Norway, Oslo Univ Hosp, Dept Med Biochem, NO-0027 Oslo, Norway
[2] Oslo Univ Hosp, Dept Pharmacol, Oslo, Norway
[3] Univ Oslo, Sch Pharm, N-0316 Oslo, Norway
关键词
LC-MS/MS; mass spectrometry; matrix effects; immunosuppressants; cyclosporine; tacrolimus; sirolimus; everolimus; WHOLE-BLOOD; SIMULTANEOUS QUANTIFICATION; ROUTINE METHOD; MS/MS METHOD; HPLC-MS/MS; IMMUNOASSAY; PLASMA; DRUGS;
D O I
10.3109/00365513.2010.531141
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objective. The immunosuppressants cyclosporine, tacrolimus, sirolimus and everolimus are used in rejection prophylaxis after transplantation. Liquid chromatography tandem mass spectrometry (LC-MS/MS) has become a widely used methodology for monitoring of the drug levels to ensure therapeutic exposure. The main objective of the study was to evaluate the existence and potential influence of matrix effects on LC-MS/MS measurements of the immunosuppressants in clinical blood samples. Methods. The samples were prepared by protein precipitation and thereafter analysed by reversed-phase chromatography coupled to MS/MS via an electrospray interface. Assay performance including within-and between-series imprecision and deviations from external controls were examined. Elution of overall matrix components and glycerophosphocholines were investigated. The MS/MS signals were monitored in post-column infusion experiments, and post-precipitation addition of compounds provided a basis for quantification of the matrix effects. The influence of matrix effects on assay performance was investigated after dilution of quality controls with blood from multiple individuals. Results. Between-series coefficients of variation were <= 5.1, <= 6.6, <= 11.0 and <= 7.4 %, and the mean deviations from external controls were -10.3, -6.7, 15.6 and 4.3% for cyclosporine, tacrolimus, sirolimus and everolimus, respectively. The elution of matrix components including glycerophosphocholines overlapped to some extent with the target compounds, and the average ion suppression ranged from 8.5-21%. However, the drugs and internal standards were correspondingly influenced. Conclusion. The internal standards consistently corrected the between-individual variability of matrix effects. These findings consolidate the reliability of the assay.
引用
收藏
页码:583 / 591
页数:9
相关论文
共 50 条
  • [41] Determination of 12 type A and B trichothecenes in cereals by liquid chromatography-electrospray ionization tandem mass spectrometry
    Klötzel, M
    Gutsche, B
    Lauber, U
    Humpf, HU
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2005, 53 (23) : 8904 - 8910
  • [42] Quantitative Determination of Cyclosporine in Human Whole Blood by Ultra-Performance Liquid Chromatography with Triple Quadrupole Tandem Mass Spectrometry
    Jung, Hyun Jin
    Gwon, Mi-Ri
    Park, Jeonghyeon
    Seo, Jeong Ju
    Seong, Sook Jin
    Kim, Eun Hee
    Suh, Soon Rim
    Jeong, Ji Yun
    Lee, Hae Won
    Yoon, Young-Ran
    ANALYTICAL SCIENCES, 2014, 30 (02) : 293 - 298
  • [43] High-throughput determination of atrasentan in human plasma by high-performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry
    Wang, PG
    Wei, J
    Chang, M
    El-Shourbagy, T
    BIOMEDICAL CHROMATOGRAPHY, 2005, 19 (09) : 663 - 670
  • [44] Pharmacokinetics and metabolic profiles of swertiamarin in rats by liquid chromatography combined with electrospray ionization tandem mass spectrometry
    Shi, Mengge
    Xiong, Kai
    Zhang, Tong
    Han, Han
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2020, 179
  • [45] Accuracy evaluation of Roche and Siemens tacrolimus and cyclosporine assays in comparison with liquid chromatography-tandem mass spectrometry
    Ko, Dae-Hyun
    Cho, Eun-Jung
    Lee, Woochang
    Chun, Sail
    Min, Won-Ki
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2018, 78 (06) : 431 - 438
  • [46] CREATININE DETERMINATION IN URINE BY LIQUID CHROMATOGRAPHY-ELECTROSPRAY IONIZATION-TANDEM MASS SPECTROMETRY METHOD
    Derezinski, Pawel
    Klupczynska, Agnieszka
    Sawicki, Wojciech
    Kokot, Zenon J.
    ACTA POLONIAE PHARMACEUTICA, 2016, 73 (02): : 303 - 313
  • [47] Determination of cymipristone in human plasma by liquid chromatography-electrospray ionization-tandem mass spectrometry
    Jiang, Bo
    Ruan, Zourong
    Lou, Honggang
    Yuan, Hong
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (7-8): : 719 - 723
  • [48] High-Sensitivity and High-Throughput Quantification of Everolimus in Human Whole Blood Using Ultrahigh-Performance Liquid Chromatography Coupled With Tandem Mass Spectrometry
    Miyagi, Chika
    Tanaka, Ryota
    Hirata, Kenshiro
    Watanabe, Takuma
    Tatsuta, Ryosuke
    Miyamura, Shigeyuki
    Itoh, Hiroki
    THERAPEUTIC DRUG MONITORING, 2022, 44 (05) : 633 - 640
  • [49] Determination of endocannabinoids in nematodes and human brain tissue by liquid chromatography electrospray ionization tandem mass spectrometry
    Lehtonen, Marko
    Storvik, Markus
    Malinen, Hanna
    Hyytia, Petri
    Lakso, Merja
    Auriola, Seppo
    Wong, Garry
    Callaway, James C.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (11-12): : 677 - 694
  • [50] Simultaneous Determination of Eight Tranquilizers in Pork by Ultra-Performance Liquid Chromatography Coupled with Electrospray Tandem Mass Spectrometry
    Liqun Zhang
    Pinggu Wu
    Quan Jin
    Haipeng Ye
    Xihui Huang
    Shaoying Liu
    Food Analytical Methods, 2017, 10 : 354 - 362