Determination of cyclosporine, tacrolimus, sirolimus and everolimus by liquid chromatography coupled to electrospray ionization and tandem mass spectrometry: Assessment of matrix effects and assay performance

被引:20
|
作者
Vethe, Nils T. [1 ]
Gjerdalen, Laila C. [1 ]
Bergan, Stein [2 ,3 ]
机构
[1] Natl Hosp Norway, Oslo Univ Hosp, Dept Med Biochem, NO-0027 Oslo, Norway
[2] Oslo Univ Hosp, Dept Pharmacol, Oslo, Norway
[3] Univ Oslo, Sch Pharm, N-0316 Oslo, Norway
关键词
LC-MS/MS; mass spectrometry; matrix effects; immunosuppressants; cyclosporine; tacrolimus; sirolimus; everolimus; WHOLE-BLOOD; SIMULTANEOUS QUANTIFICATION; ROUTINE METHOD; MS/MS METHOD; HPLC-MS/MS; IMMUNOASSAY; PLASMA; DRUGS;
D O I
10.3109/00365513.2010.531141
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objective. The immunosuppressants cyclosporine, tacrolimus, sirolimus and everolimus are used in rejection prophylaxis after transplantation. Liquid chromatography tandem mass spectrometry (LC-MS/MS) has become a widely used methodology for monitoring of the drug levels to ensure therapeutic exposure. The main objective of the study was to evaluate the existence and potential influence of matrix effects on LC-MS/MS measurements of the immunosuppressants in clinical blood samples. Methods. The samples were prepared by protein precipitation and thereafter analysed by reversed-phase chromatography coupled to MS/MS via an electrospray interface. Assay performance including within-and between-series imprecision and deviations from external controls were examined. Elution of overall matrix components and glycerophosphocholines were investigated. The MS/MS signals were monitored in post-column infusion experiments, and post-precipitation addition of compounds provided a basis for quantification of the matrix effects. The influence of matrix effects on assay performance was investigated after dilution of quality controls with blood from multiple individuals. Results. Between-series coefficients of variation were <= 5.1, <= 6.6, <= 11.0 and <= 7.4 %, and the mean deviations from external controls were -10.3, -6.7, 15.6 and 4.3% for cyclosporine, tacrolimus, sirolimus and everolimus, respectively. The elution of matrix components including glycerophosphocholines overlapped to some extent with the target compounds, and the average ion suppression ranged from 8.5-21%. However, the drugs and internal standards were correspondingly influenced. Conclusion. The internal standards consistently corrected the between-individual variability of matrix effects. These findings consolidate the reliability of the assay.
引用
收藏
页码:583 / 591
页数:9
相关论文
共 50 条
  • [31] Determination of aripiprazole in rat plasma and brain using ultra-performance liquid chromatography/electrospray ionization tandem mass spectrometry
    Liang, Feng
    Terry, Alvin V.
    Bartlett, Michael G.
    BIOMEDICAL CHROMATOGRAPHY, 2012, 26 (11) : 1325 - 1332
  • [32] Simultaneous quantification of tacrolimus and sirolimus, in human blood, by high-performance liquid chromatography - Tandem mass spectrometry
    Taylor, PJ
    Salm, P
    Lynch, SV
    Pillans, PI
    THERAPEUTIC DRUG MONITORING, 2000, 22 (05) : 608 - 612
  • [33] Determination of higenamine in human plasma and urine using liquid chromatography coupled to positive electrospray ionization tandem mass spectrometry
    Feng, Sheng
    Hu, Pei
    Jiang, Ji
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (11-12): : 763 - 768
  • [34] Determination and Quantification of Phenytoin in Human Plasma by Liquid Chromatography with Electrospray Ionization Tandem Mass Spectrometry
    Roy, S. M. N.
    Yetal, S. M.
    Vaidya, V. V.
    Joshi, S. S.
    E-JOURNAL OF CHEMISTRY, 2008, 5 (01) : 169 - 176
  • [35] Determination of clarithromycin in human plasma by liquid chromatography-electrospray ionization tandem mass spectrometry
    Jiang, Yao
    Wang, Jiang
    Li, Hao
    Wang, Yingwu
    Gu, Jingkai
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 43 (04) : 1460 - 1464
  • [36] Determination of Fatty Acids in Beef by Liquid Chromatography-Electrospray Ionization Tandem Mass Spectrometry
    Laiel C. Soliman
    Elizabeth M. Andrucson
    Kingsley K. Donkor
    John S. Church
    Bruno Cinel
    Food Analytical Methods, 2016, 9 : 630 - 637
  • [37] Determination of Fatty Acids in Beef by Liquid Chromatography-Electrospray Ionization Tandem Mass Spectrometry
    Soliman, Laiel C.
    Andrucson, Elizabeth M.
    Donkor, Kingsley K.
    Church, John S.
    Cinel, Bruno
    FOOD ANALYTICAL METHODS, 2016, 9 (03) : 630 - 637
  • [38] Determination of bencycloquidium bromide in dog plasma by liquid chromatography with electrospray ionization tandem mass spectrometry
    Jiang, Bo
    Ruan, Zourong
    Lou, Honggang
    Dong, Xinwei
    Xie, Qiangmin
    BIOMEDICAL CHROMATOGRAPHY, 2010, 24 (05) : 490 - 496
  • [39] A validated assay for the quantitative analysis of vatalanib in human EDTA plasma by liquid chromatography coupled with electrospray ionization tandem mass spectrometry
    Lankheet, A. G.
    Hillebrand, M. J. X.
    Langenberg, M. H. G.
    Rosing, H.
    Huitema, A. D. R.
    Voest, E. E.
    Schellens, J. H. M.
    Beijnen, J. H.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (29): : 3625 - 3630
  • [40] Determination of Furaltadone and Nifursol Residues in Poultry Eggs by Liquid Chromatography-Electrospray Ionization Tandem Mass Spectrometry
    Barbosa, Jorge
    Freitas, Andreia
    Mourao, Jose Luis
    Noronha da Silveira, Maria Irene
    Ramos, Fernando
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2012, 60 (17) : 4227 - 4234