An optimized fast protocol for magnetic resonance imaging of the temporomandibular joint

被引:4
作者
Honda, E [1 ]
Sasaki, T [1 ]
Simm, FC [1 ]
Maruyama, K [1 ]
机构
[1] Tokyo Med & Dent Univ, Bunkyo Ku, Tokyo 113, Japan
关键词
magnetic resonance imaging; temporomandibular joint disorders; temporomandibular joint; temporomandibular joint disc;
D O I
10.1038/sj.dmfr.4600580
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To provide a fast protocol for MR imaging of the TMJ with high contrast resolution of both soft tissue and joint fluid. Methods: A fast turbo-spin echo (TSE) pulse sequence was developed. The new technique was compared with TIW conventional spin echo (CSE) and T2W TSE sequences in imaging 57 TMJs in 50 patients. Disc location and contour and bone delineation were assessed on three images of each TMJ by one observer. Presence and location of intra-articular fluid were evaluated on both standard T2W and new TSE images. Image quality was scored on a 3 point-scale by one observer. Results: The net image acquisition time for one plane was 2 min with the new TSE sequence compared with approximately 5 - 10 min for TIW and 4 min for T2W. The new sequence provided equivalent diagnostic information to a combination of TIW CSE for disc position and contour and bone contour and T2W TSE sequence for joint fluid. Conclusions: The examination time for MRI of the TMJ can be considerably reduced with the new fast TSE pulse sequence without compromising image quality.
引用
收藏
页码:126 / 130
页数:5
相关论文
共 14 条
  • [1] SIGNAL-TO-NOISE AND CONTRAST IN FAST SPIN-ECHO (FSE) AND INVERSION RECOVERY FSE IMAGING
    CONSTABLE, RT
    SMITH, RC
    GORE, JC
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1992, 16 (01) : 41 - 47
  • [2] TEMPOROMANDIBULAR-JOINT MOTION - EFFICACY OF FAST LOW-ANGLE SHOT MR IMAGING
    CONWAY, WF
    HAYES, CW
    CAMPBELL, RL
    LASKIN, DM
    [J]. RADIOLOGY, 1989, 172 (03) : 821 - 826
  • [3] COMPARISON OF MRI AND ARTHROGRAPHY IN PATIENTS WITH FUNCTIONAL DISTURBANCES OF THE TEMPOROMANDIBULAR-JOINT
    FISCHBACH, R
    HEINDEL, W
    LIN, Y
    FRIEDRICH, R
    BROCHHAGEN, HG
    [J]. FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1995, 162 (03): : 216 - 223
  • [4] THE TEMPOROMANDIBULAR-JOINT - MAGNETIC-RESONANCE IMAGING USING SURFACE COILS
    HARMS, SE
    WILK, RM
    WOLFORD, LM
    CHILES, DG
    MILAM, SB
    [J]. RADIOLOGY, 1985, 157 (01) : 133 - 136
  • [5] RARE IMAGING - A FAST IMAGING METHOD FOR CLINICAL MR
    HENNIG, J
    NAUERTH, A
    FRIEDBURG, H
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (06) : 823 - 833
  • [6] KATZBERG RW, 1993, DIAGNOSIS TEMPOROMAN, P167
  • [7] PHASE-ENCODE ORDER AND ITS EFFECT ON CONTRAST AND ARTIFACT IN SINGLE-SHOT RARE SEQUENCES
    MULKERN, RV
    MELKI, PS
    JAKAB, P
    HIGUCHI, N
    JOLESZ, FA
    [J]. MEDICAL PHYSICS, 1991, 18 (05) : 1032 - 1037
  • [8] CONTRAST MANIPULATION AND ARTIFACT ASSESSMENT OF 2D AND 3D RARE SEQUENCES
    MULKERN, RV
    WONG, STS
    WINALSKI, C
    JOLESZ, FA
    [J]. MAGNETIC RESONANCE IMAGING, 1990, 8 (05) : 557 - 566
  • [9] OPPELT A, 1986, Electromedica (English Edition), V54, P15
  • [10] PALACIOS E, 1990, MAGNETIC RESONANCE T, P40